3. Electrical Characteristics & Test Condition

Testing Conditions: Ambient Temperature: 25±5ºC; Huminity: 45%~75%.

NO.

Items

Capacity

1

-20°C

Condition

Criterion

Rest for 1 hour after fully charged, then discharge 
with 0.33C current until the battery reaches the 
discharge cutoff voltage. Repeat above process for 
three times, if the discharge time is not less than 180 
minutes, you can stop and define the Discharging 
current*time value (Ah) as battery capacity. 

≥125Ah

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage. Store the battery at 
various temperatures for 2h and discharge the 
battery with 0.33C to the cut-off voltage. Record the 
ratio between discharging & charging capacity.

0°C

25°C

55°C

≥70%

≥80%

100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Remain capacity

≥90%

Charge /     CC (0.33C)/CV (14.6V);
                   End current: 0.05C;
                   Rest time: 1h;
Discharge / CC (0.5C);
                   End voltage: 8.0V;

Repeat above process until discharge capacity is no 
more than 80% of normal value. Accumulated times 
is defined as cycle life.

2

Cycle life (DOD%100)

≥2500 cycles

3

4

UE-12Li125BL

03

Summary of Contents for UE-12Li125BL

Page 1: ...on function 5 LITHIUM IRON PHOSPHATE BATTERY 01 This specification defines the performance of rechargeable LiFePO4 battery pack UE 12Li125BL manufactured by UPOWER S L describes the type performance technical characteristics warning and caution of the battery pack The battery pack support Bluetooth communication function Through Android and IOS APP can read the battery status and information Espec...

Page 2: ...rrent Discharge Cut off voltage Dimension Weight Storage Temperature Humidity Range 20 35 C 45 75 RH 11 12 13 14 15 16 17 18 Standard Discharge Mechanical Characteristics Storage Self discharge rate 19 Short within one month Long term above one month 10 30 C 45 75 RH 3 per month 15 per year Residual capacity 1 5 per month 8 per year Reversible capacity UE 12Li125BL Length 318 2mm Width 165 2mm Hei...

Page 3: ... 5 C discharge the battery with the current of 0 33C to the cut off voltage Store the battery at various temperatures for 2h and discharge the battery with 0 33C to the cut off voltage Record the ratio between discharging charging capacity 0 C 25 C 55 C 70 80 100 95 Charge the battery to full capacity and store it for 28 days and then discharge it with 0 33C to the cut off voltage Charge Retention...

Page 4: ...ase for each cell 3 60 0 05V Over charge release method Under the release voltage Over discharge protection for each cell 2 00 0 05V Over discharge Over discharge release for each cell 2 50 0 05V Over discharge release method Charging Discharge over current protection 400 500A Over current Protection delay time 50 200ms Over current release method Release after 30s Over Temperature Battery over te...

Page 5: ...r appear any abnormity during working or storage please stop using and take it out from device If the battery leaks and get into the eyes or skin do not wipe instead rinse it with clean water and see doctor immediately Please far away from children or pets Do not put disuse battery into a fire or water If user needs to parallel several battery packs please charge them to full capacity with same ty...

Reviews: