6. Dimensional Drawing     

Items

Over-charge protection for each cell

Specification

Content

3.75±0.025V

Over charge

Over-charge release for each cell

3.60±0.04V

Over-charge release method

Under the release voltage

Over-discharge protection for each cell

2.0±0.04V

Over discharge

Over-discharge release for each cell

2.5±0.04V

Over-discharge release method

Charge to recovery

Discharge over current protection 

420~480A

Over current

Protection delay time

20 - 40ms

Over current release method

Delay about 10S after recovery

Battery 
temperature

Charge over temperature 

Protection @65±5°C

Discharge over temperature

Release @50±5°C

Protection @65±5°C

Release @50±5°C

Short circuit

Do not short-circuit the electrodes

Designed For 480A~700A /500us

Charge over temperature protection MOS

Protection @103±10°C

Discharge over temperature protection MOS

Release @75±10°C

Protection @103±10°C

Release @75±10°C

UE-12Li100BL

04

163

158

215.5

315

327±2

264

234±2

171±2

36.5

200

Unit: mm