12
16
Priority 2: dynamic
effect
0-9
No function
10-255
Per 12 DMX value one effect, total 20 types
effect
17
Back light R
0-255
0~255 control(15CH,16CH)back light
18
Back light G
0-255
0~255 control(15CH,16CH)back light
19
Back light B
0-255
0~255 control(15CH,16CH)back light
20
Back light W
0-255
0~255 control(15CH,16CH)back light
21
Adjust effect direction
0-127
Dynamic pattern Positive direction
128-255
Dynamic pattern opposite direction
22
Speed of effect
0-255
From fast to slow
23
Priority 1
:
Marco
function
0-9
NO function
10-99
Auto Run 1
100-199
Auto Run 2
200-255
Sound Mode
24
Reset
0-239
No function
240-250
reset,valid in 3S
251-255
No function
6.Trouble Shooting
Following are a few common problems that may occur during operation. Here are some suggestions for
easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or
interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition