background image

 

 

18 

b.  Read the 

UPLINK Security Inc. Dealer Agreement

, then click 

Accept 

Agreement

c.  A box will appear saying “

You hereby accept the Uplink Security Dealer 

Agreement?

”  Click 

OK

d.  A box will appear saying “

If you want monthly service billed to a 3

rd

 party 

such as a central monitoring station then you should NOT request an 
account – please contact Uplink Sales at 888-987-5465.

”  Click 

OK

e.  At this point there will be a screen entitled “

Step 2. Rapid Signup – please 

provide Login & Contact Information

”.  Fill out this form, then click 

Sign 

Up

f. 

Go back to the Login page and use the newly created Login Name and 
Password to sign into the web site.  

Wait about 20 seconds for the next 

web page to completely install. 

g.  Go to 

Configure

h.  Go to 

Activate Unit

i.  Put in the 

Unit Serial #

j.  Choose a 

Service Plan

k.  Choose an 

Activation Type

l.  Click 

Activate Unit

m.  Now see “ 

Model 2550 Serial # <ten digit number>_ successfully activated 

 Click here to configure unit 

”. 

n.  Click 

Click here to configure unit

o.  There will now be a page entitled “

Send MT – Model 2550

”. Fill in all the 

options, then click 

Send All

 

Existing Dealer 2550 Activation: 

 
For dealers/customers who already have an account with Uplink, go to the 
Numerex/Uplink web site (

www.numerexsolutions.com

). 

 

a.  Enter the Login Name and Password.  

Wait about 20 seconds for the 

next web page to completely install.

 

b.  Go to 

Configure

c.  Go to 

Activate Unit

d.  Put in the 

Unit Serial #

e.  Choose a 

Service Plan

f.  Choose an 

Activation Type

g.  Click 

Activate Unit

h.  Now see “

Model 2550 Serial #<ten digit number>_ successfully activated 

 Click here to configure unit 

”. 

i.  Click on 

Click here to configure unit

j.  There will now be a page entitled “

Send MT – Model 2550

”. Fill in all the 

options, and then click 

Send All

 

G. Programming and Central Station Reporting 

 

Summary of Contents for 19-25133-841

Page 1: ...1 UPLINK MODEL 2550 GSM ALARM COMMUNICATOR PRODUCT ID 19 25133 841 INSTALLATION OPERATIONS AND PROGRAMMING GUIDE To download a copy of this manual go to Quick Links at www numerexsolutions com...

Page 2: ...Easy Service Initiation 5 K Web based Services 5 L UL Listed 5 3 Warranty Information and Liability Waiver 6 TERMS and CONDITIONS 6 LIMITED WARRANTY 6 INDEMNIFICATION 7 LIMITATIONS of LIABILITY 7 4 FC...

Page 3: ...the Installation and Testing 20 8 UL COMPLIANCE SECTION 21 A Household Fire UL 985 Category UTOU 21 B Household Burglary UL 1023 Category NBSX and evaluated to UL 1635 Category AMCX 22 9 Specificatio...

Page 4: ...arm panels using Contact ID SIA DC 05 Standard or SIA FSK Level 1 SIA DC 03 Standard digital dialer formats All event information sent by the alarm panel in either format Account number zone informati...

Page 5: ...are visible from outside the enclosure These LEDs can be placed into Received Signal Strength Indication mode RSSI to assist in selecting the optimal mounting location for transmitting and receiving...

Page 6: ...eof found to be defective in materials or workmanship is the exclusive remedy provided herein this remedy will not be deemed to have failed of its essential purpose so long as the Company is willing a...

Page 7: ...E FOR INTERRUPTIONS IN OR INTERFERENCE WITH THIRD PARTY TELECOMMUNICATIONS CARRIERS TRANSMISSIONS OVER WHICH THE COMPANY HAS NO CONTROL I E FOR INTERRUPTIONS OR INTERFERENCE CAUSED BY NETWORK CONGESTI...

Page 8: ...d to the telephone company The 2550 employs two USOC RJ31X jacks The RJ31X plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC...

Page 9: ...mmission for additional information If your home has specially wired alarm equipment connected to the telephone line ensure the installation of The 2550 does not disable your alarm equipment If you ha...

Page 10: ...where to mount the unit Keep the following in mind a Obtain the best transmitted and received signal strength for the cellular radio If a very strong cellular signal is not available first power the...

Page 11: ...is convenient to allow full power operation while on Battery such as finding the optimum location to install using the RSSI function S3 will allow the user to override the battery mode This switch mu...

Page 12: ...ator RSSI Mode by turning Dipswitch S4 to ON the five LEDs indicate the follow signal strength information Received Signal Strength Appearance of LEDs 1 thru 5 40 dBm 1 green solid 2 green solid 3 gre...

Page 13: ...ressing the tab on the bottom of the unit and tilting the bottom of the plastic top outward and up 2 Connect the supplied antenna with the 2550 The Antenna supplied may differ from the ones depicted i...

Page 14: ...14 Figure 1 Parts on the 2550 PC Board...

Page 15: ...terminals 13 BAT and 14 BAT respectively on the 2550 JP10 terminal strip 7 Connect the wires from the 120 to 16 5 VAC 40 VA transformer to terminal strip positions 11 and 12 designated as AC on the u...

Page 16: ...has two EOLR supervised inputs that report to the central station when activated These inputs are disabled in the default state and must be enabled via the Dealer Web Site The EOL resistors should be...

Page 17: ...example of how to connect the 2550 to the alarm panel and the telephone line Figure 3 Connections Between the 2550 and the Alarm Panel F Activating The 2550 Unit The 2550 is programmed OTA Over the Ai...

Page 18: ...ice Plan k Choose an Activation Type l Click Activate Unit m Now see Model 2550 Serial ten digit number _ successfully activated Click here to configure unit n Click Click here to configure unit o The...

Page 19: ...mally uses its built in Telephone Line Monitoring circuit to determine whether the unit should intercept the alarm panel s digital dialer or leave it connected to the premises telephone line However t...

Page 20: ...0 can be programmed to report that condition and its Restoral to the monitoring Central Station See Appendix A for a list of Contact ID format and SIA format event codes generated by the 2550 that can...

Page 21: ...ach relay Make sure the alarm panel properly detects the relay s change of state and reports the proper event to the central station f Remove AC power and Battery Power from the 2550 then trip an alar...

Page 22: ...the alarm panel and the zone must be set up as closed in the normal state and open in the off normal state Activation of this zone must annunciate locally B Household Burglary UL 1023 Category NBSX a...

Page 23: ...in the normal state and open in the off normal state Activation of this zone must annunciate locally 9 Specifications Panel to Model 2550 Interface Line Voltage 48 VDC On Hook Dial tone 350 440 Hz 0...

Page 24: ...24 Physical Height 2 5 inches Width 5 4 inches Depth 10 5 inches...

Page 25: ...estoral R200 FJ High Temperature E158 KA High Temperature Restoral R158 KR Holdup Alarm E122 HA Holdup Restoral R122 HR Low Battery E302 YT Low Battery Restoral R302 YR Low Temperature E159 ZA Low Tem...

Page 26: ...1 AR 239 Low Battery E302 YT 240 Low Battery Restoral R302 YR 240 Telco Trouble E351 LT 241 Telco Restoral R351 LR 241 Cable Supervision Trouble E616 YX 242 Cable Supervision Restoral R616 YZ 242 Cell...

Page 27: ...ocopying recording or information storage and retrieval systems The material in this manual is subject to change without notice Numerex reserves the right to make changes to any software or product to...

Reviews: