10
Quick Key
Option Name
Description and Notes
9>1>1>2
Zone Type
Type of alarm this zone generates
9>1>1>3
Arm Set
Arming methods in which the zone is included.
1 (F): The zone is included in Full arming
2 (P): The zone is included in Part arming
3 (PE): The zone is included in Perimeter arming
9>1>1>4
Descriptor
Descriptors help identify the device when the system is
being operated and programmed.
9>1>1>5
Bell (Siren)
Activate the siren when the zone is triggered
9>1>1>6
Chime
Activate the internal siren when the zone is triggered.
Note
: To enable the chime option enable Global Chime
option [quick keys:
7>12
]
9>1>1>7
Force Arm
Arm the system even if a zone is not ready. For the force
arm feature to function, you must also enable force
arming in system options.
Table 2: Parameter settings
Note
PIR and Camera PIR detector have dedicated parameters. They can be defined using
quick key 9>1>1>11
4.
If required scroll thorough the other menu parameters and modify settings as
warranted
.
Step 3: Detectors Test
1.
Go to the main display and press
'√'
.
2.
Enter the installer code (default code '1111').
3.
Select
[7]>[04]>[2]
(Service
>
Transmitters
>
TX Test) to initiate the TX
communication test. This test enables to identify transmitters and test their
signal strength.
4.
Activate the transmitter you wish to test; the transmitter’s details appear on
the iConnect LCD. As a result, a sequence of tones is heard indicating the
transmitter’s signal strength.