POWER (ON/OFF) STATUS LED
CHARGING/FAULT STATUS LED
FAULT MODE - TROUBLESHOOTING
SPECIFICATIONS:
Input Voltage
Input Frequency
Output Voltage
AGM
GEL
Fast Charge (Bulk)
Float
Output Current
Fast Charge (Bulk)
DC 5,000mA
Battery Capacity
18-50 Ah (Suggested)
Operating Temperature
Storage Temperature
Power Supply Cord
SJT, 18AWGX3C, 300V, 105 C
Red LED
(Numbers refer to the Three Stage Charge Cycle section on the previous page)
(Letters refer to the Faults section on the previous page)
ON
OFF
Charger is connected to wall outlet
Charger is not plugged in to wall outlet
Red flashing rapid
Red flashing 1 time every 3 seconds
Red flashing 2 times every 3 seconds
Red flashing 3 times every 3 seconds
Red flashing 4 times every 3 seconds
OFF
12 hour charge timeout
Battery voltage less than 14 Volts (D)
Battery connection reversed (C)
Battery voltage too high (B)
Battery drawing too much current (A)
No battery
Battery voltage less than 9 volts
Fast charge (1) (2)
Float/Maintenance charge (3)
Battery is charged
No battery
Battery voltage less than 9 volts
20 hour sleep mode (see Note)
Red ON
Green Flashing
Green ON-Steady
OFF
-13 F/-25 C to + 122 F/50 C
-13 F/-25 C to + 140 F/60 C
50-60 Hz
100-/-10%
DC 29.2V 0.2V
DC 27.0V 0.2V
DC 28.6V 0.2V
DC 26.6V 0.2V