background image

 

Operations Manual UC-MX16

 

© 2007-2010 

UPCOM TECHNOLOGIES, INC

   

This document is property of UPCOM TECHNOLOGIES, INC and is delivered on the express 
condition that it not be disclosed, reproduced in whole or in part, or used for the manufacture for 
anyone other than UPCOM without written consent, and that right is granted to disclose or so use 
any information on said document.   

 

Notice 

The information in this document was believed to be correct at the time of publication, and every 
effort was made to ensure that the most current information was shipped with each machine. If 
subsequent modifications were made to your unit, and you need information on these, please 
contact the UPCOM documentation department. 

If you have technical or editorial comments concerning this manual, please write them on 
photocopies of the relevant pages and send them to the documentation department or contact 
the Customer Service Department. This assistance will be greatly appreciated 

 

 

Manual Applicability and Symbols 

This is the general operating manual for UPCOM Receivers Please make sure that the correct 
manual is being used by verifying part number and serial number with UPCOM technical support 
team or your local distributor. 

Be prepared to furnish:   

 

Serial Number 

 

Exact Model Number 

Symbols 

The following warning and caution symbols are used throughout this manual: 

 

 

     

Warning: A hazard exists that may result in personal injury or loss of life. 

 

 

 

Caution: Failure to follow the procedures given may result in damage to the 

equipment. 

Summary of Contents for UC-16MX

Page 1: ...TRANSPORT STREAM MULTIPLEXER User Manual www upcom com...

Page 2: ...lease contact the UPCOM documentation department If you have technical or editorial comments concerning this manual please write them on photocopies of the relevant pages and send them to the document...

Page 3: ...85 to 265V Proper power cords should be used for the country where the equipment will be operated Power consumption should not exceed 50W The UC 16MX should not be operated where the unit is exposed...

Page 4: ...ront Panel Dimensions 4 3 2 Rear Panel 5 4 Operation 6 4 1 Front Panel 6 4 2 UC 16MX Operation Flow 6 4 3 Menu Structure 7 4 3 1 Setting the network address 9 4 3 3 Output number 11 4 3 4 Test mode 12...

Page 5: ...please contact customer support immediately Do not proceed installing the equipment if there is visible or perceived physical damage Warranty and RMA UPCOM guarantees this equipment against defects in...

Page 6: ...th DVB ASI output interface 2 1 Working principle Principle figure Figure2 1 Working principle explanation 1 The multiplexer supports 16 MPEG 2 SPTS or MPTS inputs and two MPEG 2 transport stream MPTS...

Page 7: ...function you can customize monitoring time and port 2 3 Technique parameter PCR 100 ns Input interface ASI Interface BNC Input interface impedance 75 Input interface bit rate max 180Mbps Input select...

Page 8: ...UC 16MX 4 3 Structure 3 1 Front Panel Dimensions Each equipment is designed for 1U 44mm space machine dimensions of equipment is shown as figure3 1 Figure 3 1...

Page 9: ...output 1 multiplex output 75 BNC 3 ASI output 2 multiplex output 75 BNC 4 The same as to ASI output 2 5 The same as to ASI output1 6 RJ 45 port network control The customer can manage the multiplexer...

Page 10: ...key enter or exit operation OK key make sure the operation 4 2 UC 16MX Operation Flow Step Appliance First Second Third Fourth Fifth Installation Setting network address Initialization Logon Reading i...

Page 11: ...UC 16MX 7 4 3 Menu Structure Figure 4 2...

Page 12: ...have three programs and output bitrate is 15Mbps output1 number Modify output1 number output2 number Modify output2 number Network address Setting network IP address Version info Display equipment ver...

Page 13: ...ut1 mumber Use key then move the cursor to network address Subnet Mask 255 255 255 000 Use key to move cursor Use key to modify number Ip Address 192 168 001 210 Use key to move cursor Use key to modi...

Page 14: ...hen the input streams must be changed or when the work status is abnormal 1 Click MENU enter into main menu 2 Click key to move master reset 3 Click OK key to enter the following figure 4 Click OK key...

Page 15: ...setting output1 number 01 P03 bitrat 000 0 02 P04 bitrat 000 0 Main interface UC 16 multiplexer Output1 Number Use key then move Cursor to output1 number UC 16 multiplexer Output1 Number Return to mai...

Page 16: ...panel keys can not be operated the equipment returns to its normal working mode after you power cycle 01 P03 bitrat 000 0 02 P04 bitrat 000 0 Main interface UC 16 multiplexer Output1 Number Use key th...

Page 17: ...the equipment Original unlock password is if you need to modify the unlock password please look procedure ahead 01 p03 bitrat000 0 02 p04 bitrat000 0 Main interface UC 16 multiplexer Output1 Number U...

Page 18: ...necessary to operate the equipment once you change it you will be only one to know the new password Please keep it on a safe known place in case you need it in the future Main interface 01 P03 bitrat...

Page 19: ...n 01 P03 bitrat 00 00 02 P04 bitrat 00 00 Main interface M216 multiplexer Output1 Number Use key and move cursor to master reset MEN U OK Master Reset Master Reset OK Click OK to make sure reset Click...

Page 20: ...tatus information Main interface 01 p03 bitrat 02 p04 bitrat Main interface UC 16 multiplexer Output1 number Use key and move cursor to version info MENU Version infor 1 0 Display version information...

Page 21: ...hannels states Green light shine Input information locked channels port opened Green light twinkle Input information but channels port unopened Red light shine Input bitrate overflow or input port ope...

Page 22: ...Multiple Programs Transport Stream N NIT Net work Information Table P PAT Program Association Table PCR Program Clock Reference PID Packet Identifier PMT Program Map Table PSI Program Specific Inform...

Page 23: ...Tel 1 408 329 4158 Fax 1 408 329 4159 website www upcom com Upcom Technologies Inc San Jos California Copyright 2007 2010...

Reviews: