background image

UP3D TECH CO.,LTD

11

figure 1-4

.

Manual detection: expert detection mode, check the status and parameters of all
components drivers and connection

figure 1-5

.

Figure 1-4

Figure 1-5

Summary of Contents for ACUBLU

Page 1: ...UP3D TECH CO LTD 1 UP3D DENTAL SYSTEM User Manual...

Page 2: ...lManager Configuration 23 2 3 1 General setting 23 2 3 2 UPCAD Configuration 24 2 3 3 UPSCAN Configuration 26 2 3 4 Manage Users 28 Authorization Management 30 Model Scanning 31 4 1 Types of dental sc...

Page 3: ...peration 62 5 1 1 Mouse operation 62 5 1 2 5 1 2 Shortcut keys operation 62 5 2 UPSCAN scanning software 63 5 2 1 5 2 1 In cloud point or mesh edit mode 63 5 2 2 Shortcut keys in impression scanning 6...

Page 4: ...nt and manufacture of dental model scanner CAD CAM dental restoration software At present the main products are high precision blue light model scanners dental design software UPCAD dental computer ai...

Page 5: ...d CPU Intel Core i7 or above or other same level CPU Graphics card NVIDIA 4G or above Memory 8GB 16GB or above Hard disc Double hard disc SSD 120G 1TB HDD 7200R Main board Please select a well known m...

Page 6: ...rdware 1 2 1 Check the scanner and accessories Accessories Quantity Picture Compatible scanners USB cable 1 All scanners Power cable 1 All scanners PCI E card 1 AcuBlu The computer must have sufficien...

Page 7: ...H CO LTD 7 Shade cloth 1 All scanners Calibration board 1 Stone calibration board All scanners Plate 1 Screw retained plate All scanners 1 Regular plate All scanners Die plate 1 6 hole die plate UP200...

Page 8: ...UP3D TECH CO LTD 8 1 12 hole die plate UP300 Impression fixtures 1 UP300 Dongle 1 All scanners User Manual 1 All scanners Figure 1 1...

Page 9: ...r port of scanner 3 Insert the UP3D dongle 4 Power on the scanner Figure 1 2 Figure 1 3 1 The connection requires a ground wire to avoid damaging the internal components of the scanner 2 Please unplug...

Page 10: ...tion location The default location is C UP3D Make sure there is enough free space to install 5 Click next check the part you want to install which defaults to full selection 6 Click next add shortcut...

Page 11: ...UP3D TECH CO LTD 11 figure 1 4 Manual detection expert detection mode check the status and parameters of all components drivers and connection figure 1 5 Figure 1 4 Figure 1 5...

Page 12: ...t the camera needs to initialize then a dialog box figure 1 7 will pop up and click the ok button The software will automatically adjust the camera and enter the calibration interface again When the s...

Page 13: ...UP3D TECH CO LTD 13 Figure 1 8 Calibration startup interface 3 Enter calibration interface figure1 9 Figure 1 9 calibration interface Adjust the appropriate gain value and exposure time...

Page 14: ...image acquisition and processing after shows calibration successful click ok figure 1 11 and exit the calibration Figure 1 10 AF interface Figure 1 11 AF interface 5 Select manual calibration method M...

Page 15: ...Figure1 12 The interface of manual calibration finishing Recollection when the image acquisition failed left click recollection or F5 to recollect Please adjust the gain value and exposure time manua...

Page 16: ...nsists of the following parts Figure 2 1 1 Menu bar 2 Order query 3 Order list 4 Design information 5 Prompt bar The menu bar includes the following functions New order button Build the new order Fuzz...

Page 17: ...tion 2 Order query Search the orders from yesterday or this week Advanced Search figure 2 2 searched by date range or by customer Figure 2 2 3 Order list Display the queried order list The basic infor...

Page 18: ...gn information Tooth diagram display the tooth number or design type of current order on the tooth diagram Model viewer preview the scan model and design model of current order 5 Prompt Dongle license...

Page 19: ...ate when the scan was completed remodeling Reset to create an order that has been scanned designed or processed reverted to the state when the creation was completed and rescanned 5 Open local file Op...

Page 20: ...k yesterday or This week icons All orders for yesterday or this week are displayed in the order list Advanced Search According to date After selecting the date range click search icon All orders durin...

Page 21: ...r calibrate interface Select column function Right click in the title bar of the order list select column in the pop up window select Hide or Show column as shown in the figure 2 6 figure 2 6 Sharing...

Page 22: ...s IP of computer A by CAD Configuration When opening UPDentalManager in the Computer B C and D it will display all created orders by computer A Double click the order it will download model files auto...

Page 23: ...ion and it can be changed 2 Save orders automatically When you are designing the order design files will be saved automatically 3 Language The default language when installed 4 Whether to transform th...

Page 24: ...nd designed model 3 UPCAD output path The folder location of designed model Default Output Order outputs in orders storage path OutputFile Custom Output The output location of designed model is define...

Page 25: ...gure 2 10 5 UPCAD order path filename format folder names used to personalize the storage order Figure 2 11 Note When you are modifying please make sure that the folder name does not conflict with the...

Page 26: ...ing color to scan the different color models Now there is 3 projecting colors available blue light red light and white light 2 Quality When scanning arch and occlusion we suggest you open the quality...

Page 27: ...usion scan defaulted is placed into the first step of the scan If not chosen the occlusion scan is placed into the final step when scanning 8 Auto split Gingiva Scan body Wax up When the Gingiva Scan...

Page 28: ...k Calibrate White Balance to complete the calibration 2 3 4 Manage Users DentalManager can be used by one technician and also can be used by other technicians at the same time For this point different...

Page 29: ...UP3D TECH CO LTD 29 Figure 2 16...

Page 30: ...The software will not open if it has not be connected or the permissions are incorrect You can open the UP3D Dongle Management by clicking the dongle button in the menu of the order management or by c...

Page 31: ...le multi dies UP300 Application scope gypsum impression bite wax scan body color texture orthodontics unsectioned model all in one model 12 hole multi dies UP500 High precision Application scope gypsu...

Page 32: ...es 4 2 1 Die scan scanning with multi dies plate scanning on the dental arch 4 2 2 Gypsum scan Full arch scan Jaw arch wax bite scan All in one scanning Partial jaw arch scan Occlusion scanning withou...

Page 33: ...CO LTD 33 4 2 3 Impression scan Single side impression scan Impression wax bite scan Triple tray impression scan Triple tray impression partial scan 4 2 4 Implant scan body scanning Scan body scan Gin...

Page 34: ...UP3D TECH CO LTD 34 4 2 5 Wax up scanning Single wax up scan Wax up bridge scan Combined wax up scan Wax up bottom scan...

Page 35: ...ng previous next scan and add scan 1 previous Function Switch to the previous step Operation Click Previous or press the Backspace button to return to the previous step 2 next Function Go to next step...

Page 36: ...al position return to zero Operation Click Axis initialization 6 Add scan Function Add scan of the model area that is not scanned comprehensively Operation Rotate the model to the angle that needs to...

Page 37: ...d incorrectly when one point is aligned click the Reset current button undo the point and then re select the point position Or if not use this button you can directly drag move the point to another lo...

Page 38: ...e software automatically calculates a circular plane according to the type of the model eg arch occlusion model etc When the function is activated and the model data below the plane is automatically s...

Page 39: ...ased when the area is selected you can press Esc to cancel the selection Polygon selection tool Operation A1 Click Polygon selection tool to enable or disable the polygon selection function A2 Click t...

Page 40: ...e scene when activated A2 Click the left button to start to drag the mouse to make a selection All data including the covered area in the sphere range is marked in red A3 Hold down the Ctrl key when s...

Page 41: ...g all selected areas A2 Hot key Ctrl R Inverse the selected areas A3 Click Delete Selected Data or press the Delete key to delete the area marked red 3 Model editing tools Hole filling tool Hole filli...

Page 42: ...ert function A2 Click the left button on a connected region of the model to perform the invert function You need to reverse the entire model if the model has only one connected area A3 Hold down the A...

Page 43: ...meets with the first point then the margin line is generated The margin line is connected in real time between every two points When the margin line is off the margin the user can click to add a new...

Page 44: ...control point by dragging the control points The control points can be dragged across the different teeth to edit the margin line of the corresponding tooth position when the margin line control point...

Page 45: ...d by default A10 Save the margin line complete the scan to save the edited margin line 4 3 3 Camera panel Function Adjust the projector brightness and switch camera view 1 Adjust projector brightness...

Page 46: ...st jaw sectioned use multi dies plate or not etc UPSCAN settings ie if use texture scan the occlusion relationship at first or not etc 4 4 1 Multi dies scanning Application For single or multiple dies...

Page 47: ...to the add scan operation in this manual A4 If you do not need to add scan click the Apply button to perform post processing of the cloud points to generate the mesh A5 Click Export and the order scan...

Page 48: ...ng models A2 Click Next Enter to scan A3 Check if it needs to add scan after the jaw is scanned if not click Apply Mark the tooth position on the working model This step has been canceled in UPSCAN ve...

Page 49: ...6 Die scanning the same as die scanning of multi dises scanning 7 Model alignment A1 Dies alignment Each die on the multi dies plate is automatically aligned to the working model A2 Occlusion alignme...

Page 50: ...you can re select the position by clicking the Reset Current button when the position of the selected point is wrong or you can directly move the point to another location or double click the point de...

Page 51: ...ing model A2 Click Next Enter to scan A3 Check if it needs to be add scan after the jaw is scanned editable if not click Apply 3 Die scanning A1 Follow the instruction of scanning guide take out the p...

Page 52: ...ect the tooth position and define a design type A2 Select the following scan options and start scanning Model source Model Occlusion Quadrant Adjacent teeth sectioned 2 Quadrant model occlusion scan A...

Page 53: ...mouse button or select the frame At this time both connected areas are displayed in red and the jaw text is displayed at the position of the first mark Figure4 11 5 Model alignment including automati...

Page 54: ...order A1 Create an order select the tooth position and define a design type A2 Select the following scan options and start scanning Model source impression Impression tray single side Occlusion oppos...

Page 55: ...canning guide then insert the working impression model A2 Click Next Enter to scan A3 Check if it needs to add scan after the working impression model is scanned editable if not click Apply 4 Opposite...

Page 56: ...s to add scan after the dental tray model is scanned editable if not click Apply 4 Automatic alignment occlusion alignment 5 The order scanning is finished 4 4 3 4 Triple tray impression scanning Part...

Page 57: ...oned Implant type customized abutment Gingiva scan yes 2 Jaw scan A1 Follow the instructions of the scanning guide then insert the jaw model A2 Click Next Enter to scan A3 Check if it needs to add sca...

Page 58: ...low the instructions of the scanning guide then insert the dies A2 Click Next Enter to scan A3 Check if it needs to add scan after the dies is scanned editable if not click Apply 4 Single wax up scan...

Page 59: ...A2 Click Next Enter to scan A3 Check if it needs to add scan after the dies is scanned editable if not click Apply 5 Automatic alignment including die and wax up alignment 6 The order scanning is fini...

Page 60: ...le wax up is scanned editable if not click Apply 6 Automatic alignment including dies and wax up alignment 7 The order scanning is finished 4 4 5 4 Gypsum model unsectioned single tooth wax up wax up...

Page 61: ...esign type Freedom scan 2 Observe side scan A1 Follow the instructions of the scanning guide then insert the front of the object A2 Click Next Enter to scan A3 Check if it needs to add scan after it i...

Page 62: ...ion Function Right button drag and drop Model rotating Wheel button drag and drop Model translating Wheel button scrolling Model zooming 5 1 2 5 1 2 Shortcut keys operation Shortcut keys Instruction E...

Page 63: ...tools Plane tool When the model is occlusion upper jaw and lower jaw Ctrl wheel button Upper plane translate wholly Alt wheel button Lower plane translate wholly When the model is single arch upper j...

Page 64: ...te upward wholly Ctrl Down translate downward wholly Alt wheel button adjust the whole translation amount 5 3 Frequently used shortcut keys of UPCAD 5 3 1 Connector Ctrl left button move wholly blue p...

Page 65: ...phing Shift left button radius adjustment 4 In wax morphing Shift wheel button radius adjustment Ctrl wheel button strength adjustment 5 Attachment Shift left button drag translate Ctrl left button dr...

Reviews: