background image

INSUBH0515

Bathroom Fan heater

replacement component list included

UBH1802

SY

ST

ÈM

E

 Q

U

AL

IT

É 

CE

RT

IFIÉ

 - REGISTERE

D Q

UA

LIT

Y S

YS

TE

M

UNIWATT is a line of products manufactured by STelpro. For more information please contact customer service.

U

ser

’s G

U

ide

this unit 

complies with 

csa standards

Summary of Contents for UBH1802

Page 1: ...list included UBH1802 S Y S T È M E Q U A L I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATT is a line of products manufactured by Stelpro For more information please contact customer service user s Guide This unit complies with CSA standards ...

Page 2: ... make sure that the anchorage used can support the total weight of the unit with the mounting brackets When cutting or drilling into a wall do not damage electrical wiring and other hidden utilities When starting up the unit for the first time or after a long period it is normal that it produces some temporary odours and whitish smoke Because this unit is hot when in use it may pose risks even in ...

Page 3: ...er the bathtub or near a sink Position the unit so the plug is easy to reach Never secure the unit to walls made of synthetic materials The fan heater must be wall mounted in a vertical position only specifications technical drawings forced air heater VOLTS 240 208 V WATTS 1800 1350 W amps 8 3 6 49 A weight 6 2 lb 2 8 kg depth 4 7 8 124 mm width 11 9 16 294 mm Height 16 3 16 411 mm technical drawi...

Page 4: ...he right indicates the airflow generated by the heater This air corridor must remain clear in order to allow good air circulation and to ensure that the unit operates efficiently Leave at least 12 in 305 mm in front of the unit Do not install the heater below an electrical outlet installation figure 1 12 305mm Minimum 2 2 2 Minimum 12 305mm Minimum 12 305mm wall wall floor figure 3 12 305mm 12 305...

Page 5: ...but the warning lamp is on Procedures to be followed Turn off the fan heater and let it cool for about 15 20 minutes It is imperative to set the thermostat and the timer to the OFF position in order to re start it Check if the dust filter is blocked and if so clean and reinstall it Turn the fan heater on again and check for proper operation If you cannot get your unit to work return it to the orig...

Page 6: ...te products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a dealer s customers or any third party for such damages Stelpro specifically disclaims all consequential incidental and contingent damages whatsoever This warranty does not cover any damages or failures resulting from 1 a faulty installation or improper storage 2 an abusive or abnormal use ...