background image

DC output switch will turn off 
automatically. 

 

 

USB output 

1

 

Turn on the main power supply. 

2

 

Press the USB output switch. After 
that, the USB power supply is 
started, the USB-A and Type-c ports 
start to output power supply, and the 
USB switch indicator is turned on at 
the same time. 

3

 

Press the USB output switch again. 
After that, the USB power supply is 
turned off, and the USB switch 
indicator is turned off. 

 

 

AC output 

1

 

Turn on the main power supply. 

2

 

Press the AC output switch. After that, 
the 230 V AC output is turned on, the 
AC socket starts to output power 
supply, and the AC switch indicator is 
turned on. 

3

 

Press the AC output switch again. After 
that, the 230 V AC output is turned off, 
and the AC output switch indicator is 
turned off.

 When the output of AC port 

is less than 15 W for 12 hours 
continuously, the AC output switch will 
turn off automatically.

 

 

 

You can press the AC output switch during AC charging to turn on the AC output to enter the EPS 
mode, and then the AC socket can take power supply directly from the AC input port. In this case, 
the  power  of  charging  and  230  V  AC  output  cannot  exceed  the  limit  power  of  AC  input  (peak 
value  <  1800  W);  otherwise,  the  AC  input  may  be  disconnected  for  protection.  In  EPS  mode, 
when  the  AC  output  power  exceeds  1400  W,  the  AC  input  cannot  power  the  battery,  and 
meanwhile the maximum AC output power is 1500 W. In EPS mode, once the power supply fails 
due to abnormal AC input, the product immediately switches to battery power supply within 30 
ms. 
During  DC  charging,  the 230  V  AC  can  still output  power  supply  normally,  that  is,  charging  and 
discharging can be performed simultaneously. 

 

Summary of Contents for ES-E2000 Series

Page 1: ...ES E2000 Series Portable Power Station User Manual Before using the product please read this manual carefully and keep it properly for future reference Zhejiang Uniview Technologies Co Ltd ...

Page 2: ...correctly it may cause injury to yourself or others or cause damage to the product and property loss Users shall be responsible for all the losses arising therefrom Accordingly the promised service warranty terms shall automatically lapse In compliance with laws and regulations the company reserves all the rights for final explanation for the documents related to the product The documents are subj...

Page 3: ...e product 7 1 Use of the product 7 2 AC charging 9 3 Car charging 9 4 Solar charging 10 5 EPS function 10 6 Indicator 11 7 Long term backup power mode 11 8 Enhanced overload mode 11 9 Automatic identification of power grid system 11 IV Fault Display and Handling 12 V Package Contents 15 VI Maintenance 15 VII Warranty 15 Disclaimer and Safety Warnings 16 ...

Page 4: ...ase find purchase information through the distribution channels specified by the company 6 It is forbidden to stack a heavy load that weighs over 30 kg 66 lbs on the product Avoid metal items such as necklaces coins and hairpins while storing the product 7 The best ambient temperature for the product is 20 C 30 C If the temperature is too high it may cause product failure or even permanent damage ...

Page 5: ...t on board an airplane because it contains lithium batteries In accordance with the international shipping regulations the lithium batteries carried on board cannot exceed 100 Wh The battery configuration of the product exceeds the specified limit for boarding 1 When the service life of the product expires or the product fails to be started due to battery over discharge the product is not worth fo...

Page 6: ...400 W and it takes about 2 0 hours to complete the 0 100 charging process This product provides multiple output ports including Anderson DC5521 car charger USB A and USB C and charging ports for the mains car charger and solar panel All the figures in the user manual are for reference only and the actual product shall prevail II Product Introduction 1 Product appearance Main power switch AC output...

Page 7: ...protection Overload protection AC input Battery percentage AC output startup AC input mode Fan operation Remaining discharging charging time DC output startup Input power USB output startup Output power For more information about fault display and handling refer to Chapter 4 2 UI ...

Page 8: ...cations AC output 4 Pure sine wave 230 V 50 60 Hz USB A output 4 5V 3A 9V 2A 12V 1 5A maximum output of 18 W USB C output 2 5 9 12 15 V 3A 20 V 5 A maximum output of 100 W Anderson output port 13 V 15 A The maximum current for power sharing by the Anderson port car charger port and DC5521 port is 15 A Car charger port 13 V 10 A DC5521 output port 2 13 V 3 A EPS function description The startup tim...

Page 9: ...midity 20 to 90 RH no condensation Storage temperature 10 C to 45 C 14 F to 113 F Storage environment humidity 70 RH no condensation Operating altitude 2000 m The product performance may vary with the actual environmental factors and the performance data may change accordingly Performance will change The actual situation shall prevail ...

Page 10: ...n state you can press the main power switch to make the display switch between on and off states After you press the main power switch to power off the product the USB power supply DC power supply and AC power supply are all turned off When all output switch are off and nothing is operated it will turn off automatically after 2 hours DC output 1 Turn on the main power supply 2 Press the DC output ...

Page 11: ... indicator is turned off When the output of AC port is less than 15 W for 12 hours continuously the AC output switch will turn off automatically You can press the AC output switch during AC charging to turn on the AC output to enter the EPS mode and then the AC socket can take power supply directly from the AC input port In this case the power of charging and 230 V AC output cannot exceed the limi...

Page 12: ...ted to the mains if you do not need to use the AC output please turn off the AC output switch otherwise it will reduce the AC charging power For the AC charging indicators refer to the following table Pressing sequence Screen display Variable charging power Full charging time Default 850 W 3 3 h First time FC 1400 W 2 0 h Second time 850 W 3 3 h After the DC input charging port is connected to a c...

Page 13: ... to light and temperature It is normal that the charging power fluctuates during photovoltaic charging This product supports charging through the same type of solar panels The company shall not bear the responsibility for any damage caused by improper operations or using different types of solar panels In EPS mode 230 V AC output is used which preferentially gets power supply from AC input and the...

Page 14: ...he power backup requirement the AC input port can always be connected to the mains and it is intelligently determined that the battery is automatically recharged every 45 days This mode is enabled by default Enhanced overload mode For the load requirements when a load exceeds the rated AC output power of the product UPS protection is performed to output power supply for the load In this case the o...

Page 15: ...d by a foreign object If yes remove the foreign object to make the fan operate properly 2 If the fan is not blocked by any foreign object it is recommended that you replace the faulty fan and send it for repair Output termination The battery is faulty and BMS protection is performed If the battery level is 0 charge the battery in time to clear the alarm Output termination The DC power supply is fa...

Page 16: ...The AC charging is abnormal and the input is abnormal The fault is generally caused because the input AC voltage is out of the range Verify that the AC voltage is within the normal range AC input termination The DC charging is abnormal and the input is abnormal The fault is generally caused because the input DC voltage is out of the range Verify that the DC voltage is within the normal range DC in...

Page 17: ...mperature to change to normal before using the product again Output termination Tip During the product operation if any of the above warning icons appears and if the icon persists flashing after the product is restarted or the environment is improved stop using the product immediately and confirm the fault type If you cannot handle the problem contact customer service for technical support It is f...

Page 18: ...ources heat sources and other conductive objects 4 If the battery level is less than 1 after use charge the battery to 60 of the full capacity before storage If the product is left idle for a long period of time with the battery in seriously low condition it may cause irreversible damage to the battery cell and may shorten the service life of the product 5 If the battery level of the product is se...

Page 19: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Visit http en uniview com Support Download_Center Product_Installation Declaration for SDoC Caution The user is cautioned that changes or modifications not expres...

Page 20: ...t this manual refers to is covered by the Waste Electrical Electronic Equipment WEEE Directive and must be disposed of in a responsible manner Battery Directive 2013 56 EC Battery in the product complies with the European Battery Directive 2013 56 EC For proper recycling return the battery to your supplier or to a designated collection point ...