20
REASSEMBLING THE SCREW
- Insert the screw REF.9 inside the
coupling REF. 11, by pushing completely
inside and making sure that the rear part
of the screw is correctly coupled with the
drive pin inside the bowl. Insert the die
REF.8 in the pin on the screw and tighten
the ring nut REF. 7 by rotating it
clockwise.
REASSEMBLING THE BLADE
- insert the blade inside the bowl by positioning it aligned with the flange REF. 18
located on the front panel of the bowl. By holding the blade into position with one
hand, insert the bar REF. 4 inside the flange and through the blade until it stops.
Rotate the lever clockwise REF. 3 to its horizontal position.
N.B: Make sure that the lever is correctly fixed in its position on the bar REF.4. If
not, push or pull towards you the bar until it is correctly aligned in order to fasten
the lever REF. 3. Then close the lid so that it rests on the bowl and make sure that
the magnet on its edge is positioned in axis with its sensor REF. B which is located
on the machine. Reassemble the liquid dosing tank REF. 1.
1
2
3
4
5
11
7
8
9
18
B
Fig. 7.3.8
Summary of Contents for UPASTA
Page 1: ...1 Operating and Maintenance Manual Ed 001 12 2020 Pasta machine UPASTA ...
Page 2: ...2 ...
Page 12: ...12 2 4 Wiring diagrams 2 4 1 Single phase wiring diagram ...