MECHANICS MAINTENANCE
REMOVAL OF COVER
The cover (Figure 2 [1]) must be removed to perform maintenance operations on the power unit. It is
secured by two screws on the top and six Phillips pan head screws on the under side.
1. DISCONNECT THE ELECTRICAL POWER CORD.
2.
Lay the unit on it’s side and remove the six screws in the bottom of the cover.
3. Stand the unit back up and remove the two screws in the top.
NOTE: Depending on the model there may be a tray support attached with these two screws.
4. Spread the sides slightly and slide the cover off the unit. Use care to avoid pulling the foam strips
off the power unit housing.
5. Reinstall the top cover in the reverse of the above procedures using care to insure that the foam
strips are not disturbed.
Pan support bracket
MG8912 only
Page 1.2
Summary of Contents for MG8912
Page 13: ...PM91 ASSEMBLY FIGURE 2 8 1 2 3 4 6 5 9 10 7 11 12 13 21 18 17 20 14 15 16 17 19 Page 6 2 ...
Page 15: ...PM91G ASSEMBLY FIGURE 3 13 16 15 17 14 18 16 19 1 12 2 11 7 3 4 5 6 8 9 10 20 Page 6 4 ...
Page 17: ...MG8912 ASSEMBLY FIGURE 4 7 9 11 1 19 2 3 4 5 6 8 10 20 12 13 14 15 16 15 17 18 Page 6 6 ...
Page 19: ...VS2000 ASSEMBLY FIGURE 5 14 16 16 17 18 13 15 19 8 10 11 12 1 2 3 4 5 6 7 9 20 Page 6 8 ...