Page 8

5.

To activate 9 volt battery and alarm, hold the QUICK DRAW

 pull-out battery drawer closed,

pull and remove the PULL-TAB.  Discard PULL-TAB.

6.

See "TAMPER LOCKING PIN."

7.

Turn on AC power and press the TEST/RESET button. Check the LED's for proper operation
(see "TESTING YOUR ALARM"). After test sequence, the Green LED lights to indicate AC
power and blinks off approximately every 20 seconds to indicate proper operation.

OPERATION, TESTING & MAINTENANCE

OPERATION: The alarm is operating once the power is connected and turned on (the battery must
also be installed).

SMOKE/COMBUSTION PRODUCTS ALARM CONDITION:  When products of combustion are
sensed, the unit sounds a loud SMOKE alarm pattern which continues until the air is cleared. For
the SMOKE alarm pattern, this alarm incorporates the internationally recognized horn signal for
evacuation. During smoke alarm mode, the horn produces three beeps followed by a two second
pause and then repeats.

CARBON MONOXIDE CONDITION: When CO is sensed at a high level or at a low level for a
lengthy period of time, the unit sounds a loud CO alarm pattern (4 short horn pulse, pause, repeat)
which continues until the air is cleared or the alarm is reset. The Red LED will flash on simultaneously
with the horn pulses.

SERVICE/TROUBLE CONDITION: Periodically, the alarm's circuitry is tested. If an error is detected,
the alarm will sound a double "beep" and the Yellow LED will flash on twice approximately every 40
seconds. If this occurs, reset your alarm (see "RESETTING YOUR ALARM"). If the SERVICE/
TROUBLE signal persists, it is an indication of circuit malfunction and that the alarm requires
immediate servicing.

TESTING YOUR ALARM: Test alarm weekly for proper operation by pushing, then releasing, the
TEST/SILENCE button. The alarm will then test itself for proper operation of BOTH the SMOKE and
CO detection and alarm circuits. The Red LED will begin to flash rapidly and the alarm will indicate
two cycles of the SMOKE alarm pattern. The Red LED will stop flashing during the second SMOKE
alarm pattern. This will be followed by two cycles of the CO alarm pattern, during which the Green
LED is off, the Yellow LED is on and the Red LED flashes on simultaneously with the horn pulses.

RESETTING YOUR ALARM: To reset your alarm, initiate the Test cycle per TESTING YOUR ALARM
above. While the alarm is indicating the CO alarm patterns of the Test Cycle, press the TEST/
SILENCE button again and HOLD it until the Test Cycle is completed (when the Yellow LED turns
off, approximately 5 seconds).

STANDBY (NON-ALARM) CONDITION: Whenever AC power is present, the Green LED is on and
blinks off approximately every 20 seconds and the Red LED is off and flashes on every 40 seconds.
If powered by the backup battery (DC) only, both the Green and the Red LED's are off and flash on
every 40 seconds.

LOCAL (ORIGINATING ALARM) CONDITION: For BOTH the SMOKE and CO alarm conditions,
the Red LED flashes on rapidly and the unit emits a loud, pulsating alarm (refer to the OPERATION
section to differentiate between the SMOKE and CO alarm patterns).

REMOTE (NON-ORIGINATING ALARM) CONDITION: For BOTH the SMOKE and CO alarm
conditions, the Red LED is off and the unit emits a loud, pulsating alarm (refer to the OPERATION
section to differentiate between the SMOKE and CO patterns).

INITIATING ALARM INDICATOR (IAI) CONDITION: Whenever a unit comes out of the LOCAL
ALARM CONDITION, it will display an IAI until  manually reset (see "RESETTING YOUR ALARM").
If the unit indicated a SMOKE alarm, the IAI is the Red LED flashing on for 1 second every 5
seconds. If the unit indicated a CO alarm, the IAI is the Green LED which flashes on for 1 second,
then off for 1 second and then repeats this cycle until it is manually reset (see "RESETTING YOUR
ALARM").

Summary of Contents for CD-9795

Page 1: ...LIKE A KITCHEN OR IN A HIGH HUMIDITY AREA NEAR A SHOWER CAN CAUSE FALSE ALARMS DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED Properly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE...

Page 2: ...ling for assistance Young children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as those emitted from appliances furnaces fireplaces and auto exhaust This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other ...

Page 3: ... ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so Page 3 IMPORTANT CONSIDERAT...

Page 4: ...n smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired more than one unit could be needed If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end Alarms can alert you to a probl...

Page 5: ...s Install at least 3 feet 0 9 meters away from these areas in extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation in areas where temperature may fall below 400 F 4 40 C or rise above 1000 F 37 80 C closer than 5 feet 1 5m from fluorescent lights electrical noise and flickering may affect the alarm s operation do not locate this alarm within 5 feet 1 ...

Page 6: ... 60Hz circuit Be sure the circuit cannot be turned off by a switch dimmer or ground fault circuit interrupter Failure to connect this unit to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting tests occur on the circuit or system Ref Section 550 17 National Electric ...

Page 7: ...les RM 100 will not respond if a CO alarm event initiates the alarm Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiates the alarm All CO alarms remain silent NOTE Units without battery backup will not respond during an AC power failure Page 7 The yellow wire is used only for multiple station operation with Universal Model...

Page 8: ...en test itself for proper operation of BOTH the SMOKE and CO detection and alarm circuits The Red LED will begin to flash rapidly and the alarm will indicate two cycles of the SMOKE alarm pattern The Red LED will stop flashing during the second SMOKE alarm pattern This will be followed by two cycles of the CO alarm pattern during which the Green LED is off the Yellow LED is on and the Red LED flas...

Page 9: ...for approximately 3 9 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present The silence feature may be used repeatedly until the air has cleared When AC power is lost the Green LED is off and flashes on approximately every 40 seconds ELECTRICAL SHOCK HAZARD Turn of...

Page 10: ...e unit Return the unit for servicing See warranty for instructions or in warranty returns There will be a service charge for repairing out of warranty units Page 10 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by a...

Page 11: ...1117 postage prepaid with a payment of 11 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW ...

Reviews: