background image

UT8962-17

PLEASE READ AND FOLLOW ALL WARNINGS

Read Operating Instructions

Always become familiar with all the

instructions and warnings before

operating any power tool.

Always Wear Approved

Eye Protection

Impact resistant eye protection

should meet or exceed the

standards as set forth in the United

States ANSI Z87.1, Occupational

and Educational Eye and Face

Protection. Look for the marking

Z87.1 on your eye protection to

insure that it is an approved style.

For further information, ANSI Z87.1,

Occupational and Educational Eye

and Face Protection, is available

from the American National

Standards Institute, Inc., 11 West
42nd Street, New York, NY 10036.

Hearing Protection is

Recommended

Hearing protection should be used

when the noise level exposure

equals or exceeds an 8 hour time-

weighted average sound level of 85

dBA. Process noise, reflective

surfaces, other tools being

operated nearby, all add to the

noise level present in your work

area. If you are unable to determine

your noise level exposure, we

recommend the use of hearing

protection.

Avoid Prolonged Exposure to

Vibration

Tools can vibrate during use.
Prolonged exposure to vibration 

or

very repetitive hand and arm

movements, can cause injury.

Stop using any tool if discomfort,

tingling feeling or pain occurs.  You

should consult your physician

before resuming use of the tool.

90 PSIG Maximum

This tool is designed to operate at

an air pressure of 90 pounds per square

inch gauge pressure (90 PSIG) maximum,

at the tool. Use of higher air pressure

can, and may cause injury.  Also, the use

of higher air pressure places the internal

components under loads and stresses

they were not designed for, causing

premature failure. The air supply should

be clean and dry, preferably lubricated.

For best results, drain the moisture from

Universal Tool

A Division of Florida Pneumatic Manufacturing Corporation

851 Jupiter Park Lane, Jupiter, Florida 33458

Toll Free 1-800-327-9403

Read these instructions carefully before attempting to install, operate

or service this Florida Pneumatic product.  Failure to comply with the

instructions could result in personal injury and/or property damage!

Retain these instructions for future reference.

Safety Instructions

The following instructions are furnished as

general guidelines for use of your pneu-

matic tool.  They cannot comprehensively

cover all possible or conceivable uses of

the subject tool.  For additional information

on the safe use of air tools, we advise you

to obtain a copy of ANSI B186.1 Safety

Code for Portable Air Tools, available from

the following source:

American National Standards

Institute, Inc.

11 West 42nd Street

New York, NY 10036.

The use of the word “shall” in the following

instructions, indicates that adherence to

the particular requirement is necessary to

conform to ANSI B186.1.

Tool Application and Usage

Portable tools shall be used only for the

purposes intended in their design and

within the capacity for which they were

intended and rated.  It shall be the tool

owner’s and/or employer’s responsibility to

instruct each operator in the safe use of

the tool.  Tools shall not be used without

guards and safety devices as furnished by

the manufacturer.  Where an air tool is

modified or altered, the modifier shall

provide the safeguards to enable it to be

safely used in the operations intended and to

comply with any applicable provisions as

contained in ANSI B186.1.

Tool Installation

Pressure regulators shall be used to limit air

pressure to the rated pressure where the

supply pressure exceeds the tool’s rated

pressure.  Air hoses and lines shall be

relieved of compressed air before being

disconnected or disjointed, unless there is

automatic valve closing protection at the joint

being separated.  Synthetic lubricants which

can cause deterioration of elastomer seals

shall not be used in air systems of air tools.

Tool Maintenance

It shall be the tool owner’s and/or employer’s

responsibility to assure that tools are

maintained in a safe operating condition.  Tool

maintenance and repair shall be performed by

authorized, trained, competent personnel.

Tools shall be disconnected from their

compressed air supply before repairs are

attempted.  Repairs shall be consistent with

the manufacturer’s recommended proce-

dures.  Tool, hoses and fittings shall be

replaced if unsuitable for safe operation.  It

shall be the tool owner’s and/or employer’s

responsibility to keep required rating

markings and warnings on the tool in legible

condition.

FPMC

WARNING:

Some dust created by power sanding,

sawing, grinding, drilling, and other

construction activities contains chemicals

known to cause cancer, birth defects or

reproductive harm. Some examples of

these chemicals are:

Lead from lead-based paints

Crystalline silica from bricks, cement

and other masonry products

Arsenic and chromium from chemi-

cally treated lumber

Your risk from these exposures varies,

depending on how often you do this type

of work. To reduce your exposure to

these chemicals, work in a well-ventilated

area and work with approved safety

equipment such as those dust masks that

are specially designed to filter out

microscopic particles.

Description

Universal Tool 1/4” QC screwdriver has an ergonimc handle design for reduced

operator fatigue.  Features a variable speed trigger and reverse for controlled

operation. Ideal for general assembly and maintenance operation. The user now

has the option of push to start operation by keeping the trigger depressed, or trigger

start operation by depressing the trigger after the tool has been held against the

fastener. Rotation of the fastener stops when the clutch reaches the set torque.

Removing the tool from the fastener or releasing the trigger will reset the tool for the

next cycle

 PUSH TO START

AUTO SHUTOFF SCREWDRIVER