background image

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Recommended Hose Bore

Size - Minimum

Recommended Max.

Hose Length

Ins

M/M

Ft

M

No

Page No 1

Low Vibration Air Saw
10mm Stroke

UT5922LV

1.21
0.55

3/8

10

30

10

10,000

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Operator Instructions

Important

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Universal Air Tool Company Limited

Unit 8

Lane End Industrial Park

High Wycombe

Bucks

HP14 3BY

Work Stations

The tool should only be used as a handheld hand operated tool. It is
always recommended that the tool is used when standing on the solid
floor. It can be used in other positions but before any such use, the oper-
ator must be in a secure position having a firm grip and footing.

Foreseen Use Of The Tool

This tool is designed for the purpose of sawing materials when fitted
with  the  saw  blades  supplied  by,  or  recommended  by  the
manufacturers. Do not use the tool for any other purpose than that
specified without consulting the manufacturer or the manufacturers
authorised representative. Do not modify the tool even for intended use
as a saw.

Putting  Into
Service

Air Supply

Use a clean lubricated
air supply that will give
a measured air pres-
sure at the tool of 90
p.s.i./6.3 bar when the
tool is running with the
trigger fully depressed.
Use  recommended
hose size and length. It

Tel No

Fax No

(01494) 883300

(01494) 883237

Vibration Level

Test Method

Tested in accordance with ISO

standards 8662 Parts 1 & 12

1.2

Noise Level

Sound Pressure Level 79.0 dB(A)

Test Method

 Tested in accordance with Pneurop

test code PN8NTC1 and ISO Standard 3744

is recommended that the tool is connected to the air supply as shown
in figure 1. Do not connect the tool to the air line system without incor-
porating an easy to reach and operate air shut off valve. The air supply
should be lubricated. It is strongly recommended that an air filter, regu-
lator, lubricator (FRL) is used as shown in Figure 1 as this will supply
clean, lubricated air at the correct pressure to the tool. Details of such
equipment can be obtained from your supplier. If such equipment is not
used then the tool should be lubricated by shutting off the air supply to
the tool, depressurising the line by pressing the trigger on the tool. Dis-
connect the air line and pour into the intake bushing a teaspoonful (5ml)
of a suitable pneumatic motor lubricating oil preferably incorporating a
rust inhibitor. Reconnect tool to air supply and run tool slowly for a few
seconds to allow air to circulate the oil. If tool is used frequently lubricate
on daily basis and if tool starts to slow or lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar and this pressure should not be exceeded.

N/A

Metres / Sec²

Air  Pressure

Recommended  Working

6.3

bar

90

PSI

Recommended  Minimum

n/a

bar

n/a

PSI

Maximum

7

bar

100

PSI

Personal Safety Equipment

Use - Safety Glasses

Yes

Use - Safety Gloves
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors

Summary of Contents for UT5922LV

Page 1: ...g with the triggerfullydepressed Use recommended hose size and length It Tel No Fax No 01494 883300 01494 883237 Vibration Level Test Method Tested in accordance with ISO standards 8662 Parts 1 12 1 2 Noise Level Sound Pressure Level 79 0 dB A Test Method Tested in accordance with Pneurop test code PN8NTC1 and ISO Standard 3744 is recommended that the tool is connected to the air supply as shown i...

Page 2: ...oving parts of the tool with clothing ties hair cleaning rags etc This will cause the body to be drawn towards the tool and can be very dangerous 15 It is expected that users will adopt safe working practices and observe all relevant legal requirements when installing using or maintaining the tool 16 Donotinstallthetoolunlessaneasilyaccessibleandeasilyoperable on off valve is incorporated in the a...

Page 3: ...ve Stem Rear Cover 33 5922LV 33 Muffle 2 34 5922LV 34 Muffle 35 5922LV 35 Muffle Cap 36 5922LV 36 Retainer Ring 37 5922LV 37 Saw Blade Ref No Part No Description 1 5922LV 01 Lever Pin 2 5922LV 02 Throttle Lever 3 5922LV 03 Bushing 4 5922LV 04 Work Guide 5 5922LV 05 Washer 6 5922LV 06 Set Screw 7 5922LV 07 Screw 8 5922LV 08 Housing 9 5922LV 09 Housing Oil Seal 10 5922LV 10 Valve Spring 11 5922LV 11...

Page 4: ... Air Tool Company Limited Unit 8 Lane End Industrial Park High Wycombe Bucks HP14 3BY England declare under our sole responsibility that the product Model UT5922LV Mini Low Vibration Saw Serial Number to which this declaration relates is in conformity with the following standard s or other normative document s EN792 Draft EN292 Parts 1 2 ISO 8662 Parts 1 2 14 Pneurop PN8NTC1 following the provisio...

Reviews: