background image

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Important

Operator Instructions

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Universal Air Tool Company Limited

Unit 8

Lane End Industrial Park

High Wycombe

Bucks

HP14 3BY

Tel No

Fax No

(01494) 883300

(01494) 883237

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Recommended Hose Bore

Size - Minimum

Recommended Max.

Hose Length

Ins

M/M

Ft

M

Foreseen Use of the Tool

This tool is designed to be used with appropriate cutting discs only..
The tool should not be used with any other type of abrasive disc or
wheel. It must never be used with saw blades or other cutting devices.
Do not use the tool outside the design intent. Never modify the tool for
any other purpose, or for its use as a disc cutter without first seeking
advice from the manufacturer or an authorised representative.

Work Stations

The tool should only be used as a hand held hand operated tool. It is
always recommended that the tool is used when standing on a solid
floor. It can be used in other positions but before any such use the
operator must be in a secure position having a firm grip and footing and
be aware of the safety rules to be obeyed when using the grinder.

Cut Off Tool

UT5762

20,000

3/8

10

30

10

No

1.7

0.8

Page No 1

Noise Level

Sound Pressure Level 86.0 dB(A)

Test Method

 Tested in accordance with Pneurop

test code PN8NTC1

Vibration Level

Test Method

Tested in accordance with ISO

standard 8662

Less than 2.5

Metres / Sec²

Air Pressure

Recommended Working

6.3

bar

90

PSI

Recommended Minimum

n/a

bar

n/a

PSI

Maximum

7.0

bar

100

PSI

Personal  Safety  Equipment

Use  -  Safety  Glasses

Yes

Use  -  Safety  Gloves

Yes

Use  -  Safety  Boots
Use  -  Breathing  Masks

Yes

Use  -  Ear  Protectors

Yes

Putting Into Service

Air Supply

Use a clean lubricated air supply that will give a
measured  air  pressure  at  the  tool  of  90
p.s.i./6.3 bar when the tool is running with the
trigger/lever 

fully 

depressed. 

Use

recommended  hose  size  and  length.  It  is
recommended that the tool is connected to
the air supply as shown in figure 1. Do not
connect the tool to the air line system without
incorporating an easy to reach and operate air
shut  off  valve.  The  air  supply  should  be
lubricated. It is strongly recommended that an

air filter, regulator, lubricator (FRL) is used as shown in Figure 1 as this
will supply clean, lubricated air at the correct pressure to the tool.
Details of such equipment can be obtained from your supplier. If such
equipment is not used then the tool should be lubricated by shutting off
the air supply to the tool, depressurising the line by pressing the trigger
on the tool. Disconnect the air line and pour into the intake bushing a
teaspoonful  (5ml)  of  a  suitable  pneumatic  motor  lubricating  oil
preferably incorporating a rust inhibitor. Reconnect tool to air supply
and run tool slowly for a few seconds to allow air to circulate the oil. If
tool is used frequently lubricate on daily basis and if tool starts to slow or
lose power.
It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar.

Summary of Contents for UT5762

Page 1: ...t Method Tested in accordance with Pneurop test code PN8NTC1 Vibration Level Test Method Tested in accordance with ISO standard 8662 Less than 2 5 Metres Sec Air Pressure Recommended Working 6 3 bar 90 PSI Recommended Minimum n a bar n a PSI Maximum 7 0 bar 100 PSI Personal Safety Equipment Use Safety Glasses Yes Use Safety Gloves Yes Use Safety Boots Use Breathing Masks Yes Use Ear Protectors Yes...

Page 2: ... whilst using the tool 10 Use only correct spare parts Do not improvise or make temporary repairs 11 Do not lock tape wire etc the on off valve in the run position The trigger lever etc must always be free to return to the off position when it is released 12 Always shut off the air supply to the tool and depress the trigger lever etc to exhaust air from the feed hose before fitting adjusting or re...

Page 3: ...5762 07 Handle Assembly 8 5762 08 Valve Pin 9 5762 09 Lever Assembly 10 5762 10 Rear Bearing 11 5762 11 Rear End Plate 12 5762 12 Cage Ref No Part No Description 13 5762 13 Rotor 14 5762 14 Rotor Blade 4 15 5762 15 Front End Plate 16 5762 16 Front Bearing 17 5762 17 Lock Nut 18 5762 18 Wave Washer 19 5762 19 Safety Guard 20 5762 20 Retainer Ring 21 5762 21 Arbor 22 5762 22 Arbor Flange 23 5762 23 ...

Page 4: ...mity Universal Air Tool Company Limited Unit 8 Lane End Industrial Park High Wycombe Bucks HP14 3BY England declare under our sole responsibility that the product Model UT5762 Cut Off Tool Serial Number to which this declaration relates is in conformity with the following standard s or other normative document s EN792 Draft EN292 Parts 1 2 ISO 8662 Parts 1 2 14 Pneurop PN8NTC1 following the provis...

Reviews: