If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.

NUISANCE ALARM SILENCE FEATURE: 

This feature is to be used only when a known alarm

condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm Silence
Feature is activated by pushing and releasing the Silence button on the smoke alarm cover. The
smoke alarm will automatically reduce sensitivity and the red LED will blink on approx. every 10
seconds to indicate the alarm is in the Silence mode. The smoke alarm will gradually regain normal
sensitivity and sound the alarm if particles of combustion are still present. The approximate 10
minute Silence feature may be used repeatedly until the air has cleared, by pushing and releasing
the Silence button again. Resetting the smoke alarm after a nuisance alarm is recommended.
NOTE:  If the Test button is pressed and held during the Silence mode, the smoke alarm will be
tested normally. Upon the release of the Test button, the Silence mode will be restarted.

Before using the alarm Silence Feature, identify the source of smoke and be certain that safe
conditions exist.

Clean the smoke alarm at least once a month

 to remove dust, dirt, insects or debris. Always disconnect

the battery power to smoke alarm before cleaning. Using a soft brush or wand attachment to a vacuum
cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris.
If the smoke alarm is false alarming and cannot be restored to normal operation, the smoke alarm
should be replaced.

BATTERY REPLACEMENT

This smoke alarm requires a 9 Volt Alkaline or Lithium battery. The battery should last for at least
one year under normal operating conditions. The smoke alarm has a low battery indicator, an audible
chirp. It will operate at approx. 40 second intervals for a minimum of 7 days. When this indication
occurs, replace the battery with an Alkaline type Energizer #522 or Lithium type Energizer LA522,
Ultralife U9VL-J or Ultralife U9VL-J-P from your local retailer.

Lithium Battery Models only - The Lithium battery is warranted to last for 10 years*
under normal operating conditions. Replace the battery with only Lithium type Energizer
LA522 or Ultralife U9VL-J or U9VL-J-P.

OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN: To make your battery drawer tamper
resistant, a locking pin has been provided (breakaway part on mounting bracket).
NOTE: If this feature has been activated, you will need to deactivate it by removing the battery
drawer tamper pin located at side of battery drawer. Refer to Page 5.
Pull the QUICK DRAW

(R) 

battery drawer open and remove the battery. While observing polarity,

push the replacement battery into the battery drawer until it is held securely in place. Carefully close
the battery drawer and reinstall the tamper pin.
Test the smoke alarm by pushing the TEST button on the smoke alarm cover until the alarm sounds,
then release.

REPAIRS AND SERVICES

If the smoke alarm is defective in any way, do not tamper with the smoke alarm. Return the smoke
alarm for servicing. (See warranty for instructions or in-warranty returns.) There will be a service
charge for repairing out of warranty smoke alarms.

DEVELOP AND PRACTICE A PLAN OF ESCAPE

BASICS OF ESCAPE PLAN

o Make a floor plan indicating all doors and windows and at least two escape routes from each

room. Second story windows may need a rope or chain ladder.

o Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire.
o Determine a place outside your home where all of you can meet if a fire occurs.
o Familiarize everyone with the sound of the smoke alarm and train them to leave your home when

they hear the sound.

o Identify children's bedrooms with red stickers placed in the upper left corner of the windows. They

are available from your local fire department.

o Practice a fire drill at least every six months. Practice allows you to test your plan before an

emergency. You may not be able to reach your children. It is important they know what to do!

Page 6

NEVER use an open flame of any kind to test  this smoke alarm. You might accidentally
damage or set fire to the smoke alarm or to your home. The built-in test switch accurately
tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).

Summary of Contents for MP308

Page 1: ...uctions 4 Locking Tamper Feature 4 Operation Testing Maintenance 5 RV Installation 5 Quick Find Alarm Originating Feature Reset 5 Cautions Warnings 6 Battery Replacement 6 Develop and Practice a Plan...

Page 2: ...ERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR L...

Page 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Page 4: ...areas near dishwashers or washing machines Install at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall...

Page 5: ...ire is present check to see if one of the reasons listed above may have caused the alarm Use the Silence Feature if it is a nuisance alarm or reset the alarm by pressing and holding the test button fo...

Page 6: ...e Energizer LA522 Ultralife U9VL J or Ultralife U9VL J P from your local retailer Lithium Battery Models only The Lithium battery is warranted to last for 10 years under normal operating conditions Re...

Page 7: ...ultiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping r...

Page 8: ...or approx 10 seconds or temporarily remove and then replace the battery This will clear alarm origination Reset alarm after every alarm event Silent 1 Chirp approx every 40 seconds Condition Low Batte...

Page 9: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Reviews: