background image

FCC PART 15 RADIO FREQUENCY DEVICES

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.

Page 9

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,

UL217 BY UNDERWRITERS LABORATORIES, INC.

Blinks On once

approx every

40-45 seconds

Stays On

AC Power is present. DC Power is present.

Blinks On once

approx every

40-45 seconds

Off

AC Power is not present and alarm is receiving DC
Power. Check the breaker or fuse box for power. If the
breaker or fuse box looks normal, call a licensed
electrician for assistance.

OPERATIONAL SUMMARY

Silent

Silent

Blinks On

approx every

2 seconds

Stays On

Nuisance Alarm - If there is no hazard present, verify
the alarm is mounted in the correct location (see User's
Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.

Horn does not

sound when other

alarms are active

or horn does not

sound when

inter-connected

alarm's test

button is pressed

Blinks On once

approx every

40-45 seconds

Stays On

or Off

Press and hold the smoke alarm Test/Silence button
for at least 5 seconds. If still no alarm, turn off AC Power
at the circuit breaker or fuse box and disconnect the
alarm from the mounting bracket and make sure the
connector plug is securely attached on units that did
not alarm. If still no alarm, have a licensed electrician
check to see if the yellow wire is connected to the neutral
wire.

3 Beeps,

2 second pause,

Repeat

Blinks On

approx every

2 seconds

Stays On

Originating Smoke Alarm - If hazard is identified, please
take all precautions if an alarm sounds by calling an
Emergency Service and getting out of the home.

3 Beeps,

2 second pause,

Repeat

Off

Stays On

Non-originating Smoke Alarm - Another interconnected
smoke alarm has sensed smoke, causing all
interconnected units to sound.

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks on
once approx every

10 seconds

(silence mode)

Stays On

QUICK FIND

®

 Alarm Origination - In an interconnected

system, it is difficult to determine which alarm initiated
the alarms to sound. The 

QUICK FIND

®

 feature will

allow you to immediately locate the originating alarm
(once  the alarms have stopped sounding). To initiate

QUICK FIND

®

, press the Test/Silence  button on any

alarm; and, after releasing the button, the originating
alarm will continue to sound for approx 60 seconds.
Reset the originating alarm. NOTE: In a non-
interconnected installation, it is necessary to test each
alarm to determine the originating alarm.

Blinks On once

approx every

40-45 seconds

Stays On

To Reset the Alarm - Hold the Test/Silence button for 10
seconds. This will clear alarm origination and clear
Silence mode. Reset after each smoke alarm event.

Silent

1 Chirp approx

 every 40 seconds

Stays On

Low Battery - Check to make sure the battery activation
pull tab has been completely removed, battery polarity
is correct and the battery terminals are making contact
with the smoke alarm contacts in the battery drawer. If
chirp continues, replace the 9V battery (see User's
Manual for recommended battery types).

3 Beeps,

2 second pause,

Repeat

3 Beeps,

2 second pause,

Repeat

Stays On

Silence Feature is activated by pressing and releasing
the Test/Silence button on the initiating alarm while in
alarm condition. Silence mode will last for approx 8-12
minutes.

Blinks On

approx every

2 seconds

Silent

(alarmed

previously)

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

SOLUTION / RECOMMENDATION

HORN

RED LED

GREEN LED

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks on
once approx every

10 seconds

(silence mode)

Blinks On once

approx every

40-45 seconds

1 Beep approx

every 60 seconds

Stays On

End-of-Service Life alarm. The alarm should be replaced
immediately.

Summary of Contents for MI100

Page 1: ...ntenance 6 QUICK FIND Alarm Originating Feature Reset 6 Cautions Warnings 7 Backup Battery Replacement 7 Develop and Practice a Plan of Escape 8 Operational Summary 9 Warranty Back Cover SECURITY INST...

Page 2: ...s A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELE...

Page 3: ...Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For a...

Page 4: ...for this model Activating one or both of these features deters someone from removing the smoke alarm from the mounting bracket or removing the battery from the alarm The breakaway locking pins are cl...

Page 5: ...nd if a CO alarm event initiates the alarm All other alarms remain silent Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiat...

Page 6: ...ORIGINATION The QUICK FIND Alarm Origination Feature allows the user to identify the initiating alarm smoke alarms in an interconnected alarm system If an interconnected alarm system is initiated by...

Page 7: ...lence mode the smoke alarm will be tested normally Upon the release of the Test button the Silence mode will be restarted Before using the alarm Silence Feature identify the source of smoke and be cer...

Page 8: ...he TEST button on the smoke alarm cover until the alarm sounds then release REPAIRS AND SERVICES This smoke alarm contains less than 1 microcurie 37 kilobecquerel ofAmericium 241 a radioactive materia...

Page 9: ...alarm have a licensed electrician check to see if the yellow wire is connected to the neutral wire 3 Beeps 2 second pause Repeat Blinks On approx every 2 seconds Stays On Originating SmokeAlarm If haz...

Page 10: ...ns E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty and...

Reviews: