RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the Test button

on any alarm for at least 10 seconds and then release. Reset after each alarm. The reset
feature will reset all interconnected units.

END-OF-SERVICE LIFE NOTIFICATION:

 A majority of home fire deaths are a result of no smoke

alarms or no 

working

 smoke alarms. In addition to the "replace by date" stamped on the back of your

alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time
to replace your alarm, which is after approximately 10 years of operation from initial power up, the
alarm will sound 1 beep approx. every 60 seconds and the red LED will blink on once approx. every
40-45 seconds. The green LED stays on. The alarm should be replaced immediately.
The end-of-service life signal can be silenced for approximately 6 hours. To perform this function,
press and release the test button. The alarm will sound for approximately 60 seconds while it resets.
After the reset function is completed, the alarm will be silent for approximately 6 hours. The end-of-
service life signal will activate after the silence period.

If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.

NUISANCE ALARM SILENCE FEATURE: 

This feature is to be used only when a known alarm

condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm Silence
Feature is activated by pushing and releasing the Silence button on the smoke alarm cover while in
alarm condition. The smoke alarm will automatically reduce sensitivity and the red LED will blink on
approx. every 2 seconds to indicate the alarm is in the Silence mode. The smoke alarm will gradually
regain normal sensitivity and sound the alarm if particles of combustion are still present. The 8-12
minute Silence feature may be used repeatedly until the air has cleared, by pushing and releasing
the Silence button again. Resetting the smoke alarm after a nuisance alarm is recommended.

NOTE:  If the Test button is pressed and held during the Silence mode, the smoke alarm will be
tested normally. Upon the release of the Test button, the Silence mode will be restarted.

Before using the alarm Silence Feature, identify the source of smoke and be certain that safe
conditions exist.

(UTHA) MAINTENANCE: 

The smoke alarm is virtually maintenance free. However, under dusty

conditions, a vacuum hose may be used to clear the sensing chamber of dust.

Clean the smoke alarm at least once a month

 to remove dust, dirt, insects or debris. Always turn

off power to smoke alarm before cleaning. Using a soft brush or wand attachment to a vacuum
cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris.

NEVER use an open flame of any kind to test this smoke alarm. You might accidentally damage
or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the
smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).

(UTHA) Sensitivity Indicating Means

The sensitivity indicating means for this Smoke and Fire Alarm is the use of the analyzer for Smoke
Detectors Model 501-A or 501-A/Bat Aerosol Generator Manufactured by Gemini Scientific Corp.,
1122-B Aster Ave., Sunnyvale, CA 94086.

The Equivalent UL 268 Light obscuration %/Ft as measured by this instrument must be within the
obscuration listed on the back of this alarm.

(UTHA) Go/No-Go Field Test

The Go/No-Go test for this smoke and fire alarm is to use one of the following UL listed can-type
aerosol smoke alarm testers. The instructions for use are printed on the canister. Home Safeguard,
Model 25S.

BACKUP BATTERY REPLACEMENT

Disconnect AC power before changing battery. Shock hazard exists if AC power is miswired.

The smoke alarm uses a 9 Volt battery. The battery should last for at least one year under normal
operating conditions. The smoke alarm has a low battery indicator, an audible beep or chirp. It
will operate at approx. 40 second intervals for a minimum of 7 days. When this indication occurs,
replace the battery with an Alkaline type (Energizer #522, Duracell #MN1604) or Lithium type
(Ultralife U9VL-J or Ultralife U9VL-J-P) from your local retailer.

LITHIUM Battery Models only - The LITHUM battery is warranted to last for 10 years under normal
operating conditions. Replace the battery with only LITHIUM type: (ULTRALIFE: U9VL-J or Ultralife
U9VL-J-P).

OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN: To make your battery drawer tamper
resistant, a locking pin has been provided (breakaway part on mounting bracket).

Summary of Contents for MI100

Page 1: ...ntenance 6 QUICK FIND Alarm Originating Feature Reset 6 Cautions Warnings 7 Backup Battery Replacement 7 Develop and Practice a Plan of Escape 8 Operational Summary 9 Warranty Back Cover SECURITY INST...

Page 2: ...s A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELE...

Page 3: ...Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For a...

Page 4: ...for this model Activating one or both of these features deters someone from removing the smoke alarm from the mounting bracket or removing the battery from the alarm The breakaway locking pins are cl...

Page 5: ...nd if a CO alarm event initiates the alarm All other alarms remain silent Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiat...

Page 6: ...ORIGINATION The QUICK FIND Alarm Origination Feature allows the user to identify the initiating alarm smoke alarms in an interconnected alarm system If an interconnected alarm system is initiated by...

Page 7: ...lence mode the smoke alarm will be tested normally Upon the release of the Test button the Silence mode will be restarted Before using the alarm Silence Feature identify the source of smoke and be cer...

Page 8: ...he TEST button on the smoke alarm cover until the alarm sounds then release REPAIRS AND SERVICES This smoke alarm contains less than 1 microcurie 37 kilobecquerel ofAmericium 241 a radioactive materia...

Page 9: ...alarm have a licensed electrician check to see if the yellow wire is connected to the neutral wire 3 Beeps 2 second pause Repeat Blinks On approx every 2 seconds Stays On Originating SmokeAlarm If haz...

Page 10: ...ns E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty and...

Reviews: