background image

Table of Contents:

Page #

Smoke Alarm Limitations and Functions ................................. 2

Recommended Location of Alarms ......................................... 2

Avoid These Locations ........................................................... 3

Early Warning ......................................................................... 4

Installation Instructions ........................................................... 4

Electrical Shock Hazard ......................................................... 4

Locking/Tamper Feature ......................................................... 4

Wiring Instructions .................................................................. 5

Operation, Testing & Maintenance .......................................... 6

QUICK FIND

®

 Alarm Originating Feature & Reset .................. 6

Cautions/Warnings ................................................................. 7

Backup Battery Replacement ................................................. 7

Develop and Practice a Plan of Escape .................................. 8

Operational Summary ............................................................. 9

Warranty ................................................................. Back Cover

SECURITY INSTRUMENTS, INC.

MODEL MI106, MI106L

MODEL MI100, MI100L

READ ALL INSTRUCTIONS

This smoke alarm uses an extremely small amount of a radioactive
element in the ionization chamber. Do not tamper with radioactive sealed
source or try to repair the smoke alarm yourself.

Summary of Contents for MI100

Page 1: ...ntenance 6 QUICK FIND Alarm Originating Feature Reset 6 Cautions Warnings 7 Backup Battery Replacement 7 Develop and Practice a Plan of Escape 8 Operational Summary 9 Warranty Back Cover SECURITY INST...

Page 2: ...s A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELE...

Page 3: ...Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For a...

Page 4: ...for this model Activating one or both of these features deters someone from removing the smoke alarm from the mounting bracket or removing the battery from the alarm The breakaway locking pins are cl...

Page 5: ...nd if a CO alarm event initiates the alarm All other alarms remain silent Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiat...

Page 6: ...ORIGINATION The QUICK FIND Alarm Origination Feature allows the user to identify the initiating alarm smoke alarms in an interconnected alarm system If an interconnected alarm system is initiated by...

Page 7: ...lence mode the smoke alarm will be tested normally Upon the release of the Test button the Silence mode will be restarted Before using the alarm Silence Feature identify the source of smoke and be cer...

Page 8: ...he TEST button on the smoke alarm cover until the alarm sounds then release REPAIRS AND SERVICES This smoke alarm contains less than 1 microcurie 37 kilobecquerel ofAmericium 241 a radioactive materia...

Page 9: ...alarm have a licensed electrician check to see if the yellow wire is connected to the neutral wire 3 Beeps 2 second pause Repeat Blinks On approx every 2 seconds Stays On Originating SmokeAlarm If haz...

Page 10: ...ns E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty and...