MRX-10 A
DVANCED
N
ETWORK
S
YSTEM
C
ONTROLLER
Rear Panel Descriptions
The rear panel ports are:
DC 12V Power: Attach the included 12V DC 3.5A power supply here.
LAN Connection: RJ45 standard 10/100 Ethernet connection to the
local network.
URC USB Port: USB port for future expansion.
IR Outputs: Eight standard 3.5mm IR emitter ports with individual
output level adjustment screws.
Relays NO, NC, COM: Two programmable relays to be normally
opened (NO), normally closed (NC) or momentary contacts. An
application should be less than 30V/.5A.
Sensors: Four sensor ports allow programming of state dependent
and triggered macros. Compatible with URC Video (URC part: VID)
and voltage (URC part: VS-100) sensors.
12V OUT: Two programmable 12V/0.2A outputs. Each may be pro-
grammed to turn on, off or momentarily toggle its output.
RS-232: Four RS-232 ports support Tx(Transmit), Rx(Receive) and
GND(Ground) connections for two way communication.
Compatible with URC cables RS232F and RS232M.
Trigger In: IR and RF trigger input ports allow integration with other
control systems and remotes.
RFTX-1: Attach an optional RFTX-1 transmitter to control URC
Lighting products via 418MHz or 433.92MHz wireless RF.
DC 12V
Power
URC
USB
Relay: NO,
NC, COM
12V Out
Trigger In
RFTX-1
RS-232
Ports
Sensors
IR Outputs: #1-8
LAN
Summary of Contents for total control MRX-10