background image

USER MANUAL

RAW

 

1.7

 

| RAW

 

3

RAW

 

5

 

| RAW

 

10

Notice
AVOID EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED LIGHT
CLASS 4 LASER PRODUCT

Manufactured / Certified by

Unity Lasers s.r.o.

Odborárska 23

831 02 Bratislava

Slovakia, Europe

Classified per IEC 60825-1: 2014
Complies with US FDA CDHR laser safety
standards 21 CFR 1040.10 & 1040.11
and Laser notice 56

Summary of Contents for RAW 1.7

Page 1: ...URE TO DIRECT OR SCATTERED LIGHT CLASS 4 LASER PRODUCT Manufactured Certified by Unity Lasers s r o Odborárska 23 831 02 Bratislava Slovakia Europe Classified per IEC 60825 1 2014 Complies with US FDA CDHR laser safety standards 21 CFR 1040 10 1040 11 and Laser notice 56 ...

Page 2: ...STS 15 E STOP FUNCTION 15 INTERLOCK RESET FUNCTION POWER 15 KEY SWITCH FUNCTION 15 INTERLOCK RESET FUNCTION REMOTE INTERLOCK BYPASS 15 MODEL SPECIFICATION 16 PRODUCT SPECIFICATION RAW 1 7 16 FRONT REAR PANEL VIEW RAW 1 7 17 DIMENSION DETAILS RAW 1 7 18 PRODUCT SPECIFICATION RAW 3 19 FRONT REAR PANEL VIEW RAW 3 20 DIMENSION DETAILS RAW 21 PRODUCT SPECIFICATION RAW 5 22 FRONT REAR PANEL VIEW RAW 5 2...

Page 3: ...nual If you have any questions or find any errors please contact us directly to help address this WHAT IS INCLUDED INTRODUCTION NAME Raw series Laser Control cable ILDA 10m Power cord 1 5m Keys for Projector key switch Keys for E stop box E stop box Unity E stop box connecting cable 10m Remote interlock bypass 3pin User guide PCS 1 1 1 2 2 1 1 1 1 Remark UNPACKING INSTRUCTIONS Open the package and...

Page 4: ...irs carried out by unskilled people can lead to damage or malfunction of the unit as well as exposure to dangerous laser light Never connect this product to a dimmer pack Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry a product from the power cord or any moving part Always use the hanging mounting bracket or the hand...

Page 5: ...nual Always set up and install all laser effects so that all laser light is at least 3 metres 9 8 feet above the floor on which people can stand See the Proper Usage section later in this manual After set up and prior to public use test the laser to ensure proper function Do not use if any defect is detected Laser Light Avoid Eye or Skin Exposure to Direct or Scattered Light Do not point lasers at...

Page 6: ...ers to be used under the guidelines of ANSI Z136 1 UNITY Lasers s r o Laser Classification Class 4 Red Laser Medium AlGaInP 639 nm depending on model Green Laser Medium InGaN 520 525 nm depending on model Blue Laser Medium InGaN 445 nm to 465 nm depending on model Beam Diameter 10 mm at aperture Divergence each beam 2 mrad Maximum total output power 1 7 3 5 W depending on model LASER COMPLIANCE ST...

Page 7: ...ng Label TOP PANEL 4 Logotype Danger Label 5 Aircraft Warning Label 6 Manufacturer Label 7 Certification Label 8 Interlocked Housing Label duplicate label is located inside the laser projector and is visible when the top cover is removed See next page for large reproductions of the product labels All these labels must be intact and legible prior to using the projector ...

Page 8: ...PUT AT __ nm __ W MAX OUTPUT AT __ nm CAUTION LASER LIGHT IS BRIGHT AND BLINDING DO NOT SHINE AT AIRCRAFT OR VEHICLES AT ANY DISTANCE CAUTION CLASS 4 VISIBLE LASER RADIATION WHEN OPEN AND INTERLOCKS DEFEATED AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION Logotype Danger Label Hazard Warning Symbol Aperture Label Aircraft Warning Label Interlocked Housing Label ...

Page 9: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 9 Laser Light Warning Label Manufacturer Label Certification Label ...

Page 10: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 10 INTERLOCK CONNECTION DIAGRAM ...

Page 11: ... Note that the E stop box has an available secondary interlock port The secondary port is to be used to interface a secondary interlock device e x door switch or pressure sensitive step pad If a secondary interlock device is NOT used then the secondary port must have the bypass shunt plug inserted The diagram below outlines the pinout configuration for the 3 pin connection from E STOP box to the r...

Page 12: ...must use safety cables International laser safety regulations require that the laser products must be operated in the fashion illustrated below with a minimum of 3 metres 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 metres of horizontal separation is required between laser light and the audience or other public spaces The audience area can ...

Page 13: ...ht show variance from the US FDA CDRH INSTRUCTIONS FOR POWERING ON THE LASER SYSTEM 1 Connect power cable and E stop 2 Connect the 3 pin Interlock cable between the E stop box and projector pull up the red mushroom switch and turn on the key switch Press the start button Confirm secondary E stop port has either the bypass plug installed or a secondary interlock device attached 3 Connect the DB25 I...

Page 14: ...M 1 Turn off the key switch and deactivate via the red mushroom switch on the E stop box You can remove the 3 pin Interlock bo too if the laser will be kept for no use We recommend having a professional operator to keep the keys and 3 pin Interlock switch 2 Turn off the power to the projector via the power switch ...

Page 15: ... begin emitting laser light Verify that the emission indicator is now lit KEY SWITCH FUNCTION With the projector operating and projecting laser light turn the key switch on the remote E stop control unit to off The projector must shut off immediately Turn the key switch back to on The projector must not emit any laser light Press the start button on the E stop box The projector should now re start...

Page 16: ...and FDA regulations 5 3 kg Carton box power cord 10m ILDA signal cable E STOP box with 10m cable set of 4 safety keys remote interlock bypass user guide 350 500 1000 5 x 3 1mrad full angle analog 50kHz 100 230V 50Hz max 100W 10 40 C IP 20 All the adjustments such as power output of each colour X Y axes invert X Y size and position etc Scanning system protection daisy chain of emergency STOP signal...

Page 17: ...ble only when the interlock is connected It could be used to connect a laser emergency switch 5 Key switch Turn the key switch ON to allow laser output 6 Power in out AC100 240V power input and output sockets With output feature you can connect the device to one another using the input and output sockets They must be the same fixtures DO NOT mix fixtures 7 Power ON OFF Power on off 8 Fuse Current ...

Page 18: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 18 Dimension details Raw 1 7 ...

Page 19: ...lations 5 3 kg Carton box power cord 10m ILDA signal cable E STOP box with 10m cable set of 4 safety keys remote interlock bypass user guide 500 800 1700 5 x 3 1 1 mrad full angle Analog 50kHz 100 230V 50Hz max 100W 10 40 C IP 20 All the adjustments such as power output of each colour X Y axes invert X Y size and position etc Scanning system protection daisy chain of emergency STOP signal for mult...

Page 20: ...le only when the interlock is connected It could be used to connect a laser emergency switch 5 Key switch Turn the key switch ON to allow laser output 6 Power in out AC100 240V power input and output sockets With output feature you can connect the device to one another using the input and output sockets They must be the same fixtures DO NOT mix fixtures 7 Power ON OFF Power on off 8 Fuse Current r...

Page 21: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 21 Dimension details Raw 3 ...

Page 22: ...lations 8 kg Carton box power cord 10m ILDA signal cable E STOP box with 10m cable set of 4 safety keys remote interlock bypass user guide 1200 1000 2800 5 x 3 1 1 mrad full angle Analog 50kHz 100 230V 50Hz max 150W 10 40 C IP 20 All the adjustments such as power output of each colour X Y axes invert X Y size and position etc Scanning system protection daisy chain of emergency STOP signal for mult...

Page 23: ...le only when the interlock is connected It could be used to connect a laser emergency switch 5 Key switch Turn the key switch ON to allow laser output 6 Power in out AC100 240V power input and output sockets With output feature you can connect the device to one another using the input and output sockets They must be the same fixtures DO NOT mix fixtures 7 Power ON OFF Power on off 8 Fuse Current r...

Page 24: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 24 Dimension details Raw 5 ...

Page 25: ...tions 12 kg Carton box power cord 10m ILDA signal cable E STOP box with 10m cable set of 4 safety keys remote interlock bypass user guide 2700 2700 4800 5 x 3 1 1 mrad full angle Analog 50kHz 100 230V 50Hz max 350W 10 40 C IP 20 All the adjustments such as power output of each colour X Y axes invert X Y size and position etc Scanning system protection daisy chain of emergency STOP signal for multi...

Page 26: ...le only when the interlock is connected It could be used to connect a laser emergency switch 5 Key switch Turn the key switch ON to allow laser output 6 Power in out AC100 240V power input and output sockets With output feature you can connect the device to one another using the input and output sockets They must be the same fixtures DO NOT mix fixtures 7 Power ON OFF Power on off 8 Fuse Current r...

Page 27: ...UNITY Lasers s r o Raw series Operational Manual Revision 2020 7 27 Dimension details Raw 10 ...

Page 28: ...2020 7 28 ILDA PINOUT SPECIFICATION 1 X 2 Y 3 Intensity Blanking 4 Interlock A 5 R 6 G 7 B 8 Deep blue 9 Yellow 10 Cyan 11 Z 12 Not connected 13 Shutter 14 X 15 Y 16 Intensity Blanking 17 Interlock B 18 R 19 G 20 B 21 Deep blue 22 Yellow 23 Cyan 24 Z 25 Ground ...

Page 29: ...oth to wipe down the outside projector casing Use compressed air and a brush to wipe down the cooling vents and fan grill s Clean the glass panel laser aperture with glass cleaner and a soft cloth when dirty Gently polish the glass surface until it is free of haze and lint Always be sure to dry all parts completely before plugging the unit back in SERVICE There are no user serviceable parts inside...