Standard Terms of Warranty

Land Instruments International warrant all products of our own manufacture to be within specified limits of calibration,

if any, when despatched from our works. Also that they are free from defects in material and workmanship for

normal use and service when used for their intended purpose within the limits of our specification. The period of

warranty, with respect to defects in material and workmanship, will be one year from date of despatch, or readiness

for despatch should delivery be delayed by the customer who has been notified of the readiness at or after the

acknowledged estimated date of despatch.

Land Instruments International guarantees to repair any defective workmanship or replace at its own option any

defective parts in any product of its manufacture, provided that the defective instrument is returned to our works

free of charge and securely packed. Also, provided that the said goods are found to be solely defective due to faulty

design, materials or workmanship and not by improper use or accident.

Items which under their normal course of use or storage, age or deteriorate e.g. measuring cells, batteries, vacuum

tubes, thermocouples, are not covered by this warranty, and will be charged for if replaced together with labour

charges for any work found not to be covered by the warranty and any transport or import charges incurred by Land

Instruments International at the customers expense.

Equipment or components purchased by Land Instruments International from other manufacturers and used with or

within Land Instruments International equipment bear only the warranty of the original manufacturer.

Warranty work will only be carried out on site on receipt of an official order from the customer who will be charged

for all travelling time plus travelling and living expenses involved to carry out the work. Should the said faulty opera-

tion not be the cause of the instrument’s faulty design, materials or workmanship, but due to application conditions,

Land Instruments International reserve the right to charge additionally for all labour on establishing this at

the customer’s works.

Warranty cover is subject to the correct planned maintenance being done in accordance with the published service

schedule. Failure to follow the planned maintenance will void the warranty terms. Any warranty claim in this event

will be at the discretion of Land Instruments International.

Whilst every care is taken in the manufacture of our products, we can accept no responsibility for any consequential

loss, however caused, through the failure of any of our products to operate accurately or correctly.

All products except 4500mkIII

The standard warranty on new instruments is a 1-year return-to-base warranty, including all electrochemical cells.. If

repairs are performed at site, then travelling time and expenses will be charged at standard rates. Purchased Spare

Parts are warranted for 1 year from date of shipment, carriage included. If a Spare Part is supplied under warranty,

then this part is only warranted for the residue of the applicable warranty period. Calibration filters are not warranted

against any damage or change in characteristic that may occur due to mishandling.

Model 4500mkIII

The standard warranty on new instruments is a 3-year return-to-base warranty. If repairs are performed at site, then

travelling time and expenses will be charged at standard rates. Purchased Spare Parts are warranted for 1 year from

date of shipment, carriage included. If a Spare Part is supplied under warranty, then this part is only warranted for

the residue of the applicable warranty period. Calibration filters are not warranted against any damage or change in

characteristic that may occur due to mishandling. The 4500mkIII light source has a lifetime warranty.

Exclusions

1. Warranty subject to the analysers being used in the manner for which they were designed

2. Warranty subject to all recommended maintenance being performed as defined in the operating

or service manual or in the quotation

3. The following consumable items are specifically excluded: All filters, Chemical filters, Chemical

Drying Agents, Batteries.

Summary of Contents for Land Vision280

Page 1: ...User Guide Control Room Unit for Model 9100 Carbon Monoxide Monitor Publication Number 807248 Language English Issue 2 January 2013 www landinst com Combustion and Environmental Monitoring ...

Page 2: ...on It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and high pressures Suitable protective clothing along with face and eye protection must be worn Refer to the health and safety guidelines for the machinery equipment before installing this product If in doubt contact Land Instruments International Electrical Power Supply Bef...

Page 3: ...ents International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmental monitoring and non contact temperature measuring instrumentation Approvals apply in the USA This instrument complies with current European directives relating to Electromagnetic Compatibility 89 336 EEC and Low Voltage Directive 73 23 EEC The Quality Management System of Am...

Page 4: ......

Page 5: ...on Assembly and Installation Instructions 4 Connecting the Control Room Unit to the Carbon Monoxide Monitor 4 Direct Connection to Transceiver 4 Customer Connections 5 Control Panel 6 Password Entry 7 Menu Tree 8 Technical Specification 9 Setting Configurable Parameters 10 Setting Date and Time 10 Setting Displays 10 Calibration 11 Parameter Table 12 Parameter Table 12 ...

Page 6: ......

Page 7: ... unit is not suitable for use with any other equipment The control room unit must be protected from dust and moisture However the front panel is fully weatherproof to IP 65 once it has been installed into a suitable panel or enclosure A 5 A external circuit breaker must be provided input output module optional control panel cable connector power supply optional Model 9100 Carbon Monoxide monitor C...

Page 8: ... 24 206 8 11 15 5 6 1 72 2 8 95 5 3 72 49 1 92 gasket Dimensions of Control Room Unit 260 10 24 earth ø4 0 15 5 0 19 35 1 38 126 4 96 155 6 1 Dimensions of Cutout earth assembly supplied with control room unit front view The diagram shows the optional input output unit installed ...

Page 9: ...s the user s responsibility to ensure compliance with all applicable wiring safety and EMC regulations Dimensions Height 176 mm 6 9 Width 483 mm 19 0 Depth 135 mm 5 3 NOTE All inputs and outputs will require connection by the customer plus a suitable mains power supply into the 24 V dc power supply unit F1 F2 F3 F4 F5 F6 F7 F8 F9 ESC i 3 def 6 mno 9 wxyz 1 symbol 4 ghi 7 pqrs 2 abc 5 jkl 8 tuv 0 1...

Page 10: ...metal plate earth the power supply Connecting the Control Room Unit to the Carbon Monoxide Monitor The common connection should be connected as shield to the 0 V terminal of the control room unit A two pin connector is supplied with the control room unit Connect to port COM3 of the control room unit The Control Room Unit is connected directly to the Model 9100 receiver Direct Connection to Transce...

Page 11: ...AOUT0 AOUT1 AOUT2 AOUT3 ANALOG OUTPUTS 24VDC ANALOG I O 0V V1 24VDC DIGITAL OUTPUTS DIGITAL OUTPUTS O16 O15 O14 O13 O12 O11 O10 O9 O8 O7 O6 O5 O4 O3 O2 O1 O0 V H PE L V V 0V 24 V 0 V Electrical Connections Customer Connections COM 4 20mA Output Common AOUT0 4 20mA Output 1 AOUT1 4 20mA Output 2 O2 Alarm Relay 1 O3 Alarm Relay 2 O4 System OK Relay O5 Fault OK Relay Note The terminal immediately to ...

Page 12: ... Sensitive Screen Where a selection may be made by touching the screen touch the back square Scroll Keys The four arrow keys may be used to scroll through selections On certain screens they can be used to move between parameters Where this is possible it is indicated on the screen Key Pad This is used to enter numeric values for example entering the password Escape This can be used to exit a menu ...

Page 13: ...word XXXX Press ESC to Return To Main Menu 1 2 3 6 5 4 9 8 7 symbol abc def ghi jkl mno pqrs tuv wxyz 0 Password Entry The password is 417 Enter the password from the key pad and then press the enter key Once entered the password remains valid for 10 minutes or until the F8 key is pressed ...

Page 14: ...rameters page 5 Faults List of active faults Calibration Start Cal Check Start Zero Cal Setup Set Modbus Address O P Range 1 O P Range 2 Alarm 1 Alarm 2 Faults Any faults indicated by the Model 9100 can be viewed on the Faults display If no faults are found the display will show No Faults If faults are present the display will indicate the relevant fault message Multiple faults can be viewed by sc...

Page 15: ...ts 10 ppm to 10000 ppm Status relays System OK and Fault relays Relays SPST Form A All relays share a common terminal Max current 2 A Max voltage 240 Vac 30 Vdc Electrical Data Power Supply 24 V d c Range 20 4 to 28 8 V Power Consumption 8 W Environmental Data Operating Temp 0 to 50 C 32 to 122 F Environmental Protection Front IP65 NEMA 4X Rear IP20 NEMA 1 Electrical Safety EN 61131 2 EMC EN 61000...

Page 16: ... value Alarm 2 value Note Alternative addresses may be used if provided the analyser Station No is the same as the 9100 Modbus Address set on the CRU Setting Date and Time 1 Press the i key for 5 seconds and then enter the password 1111 2 Select the Menu item Time and Date 3 Select New Time to set the time Time format is hh mm ss using a 24 hour clock 4 Select New Date to set the date Date format ...

Page 17: ... the display The Control Room Unit will lock automatically after 10 minutes of inactivity alternatively it can be locked manually by pressing the F8 key A calibration check may be initiated at any time by touching the Start Cal Check button A zero calibration must only be performed when there is no carbon monoxide in the optical path of the model 9100 Therefore a zero calibration must not be perfo...

Page 18: ...tput 2 Span Value Output 2 Damping Parameters page 3 Output 1 in cal Track or Hold Output 2 in cal Track or Hold Report time Flue temperature Source CLIP Range CLIP Minimum value CLIP Maximum value Parameters page 4 Flue temperature Alarm Alarm limit Alarm Hysteresis CO2 concentration H2O concentration Flue pressure Parameters page 5 Flue pressure Check Cycle Check Cycle Period Display Contrast Ba...

Page 19: ...workmanship but due to application conditions Land Instruments International reserve the right to charge additionally for all labour on establishing this at the customer s works Warranty cover is subject to the correct planned maintenance being done in accordance with the published service schedule Failure to follow the planned maintenance will void the warranty terms Any warranty claim in this ev...

Page 20: ......

Reviews: