background image

 

Unitronics 

 

 

Jazz

™PLC+HMI 

Micro-PLC+HMI Installation Guide 

JZ20-UN20/JZ20-J-UN20

 

9 Digital Inputs, 2 Analog/Digital Inputs, 1 Analog Input 

1 PT100/TC , 5 Relay Outputs, 2 PNP Outputs 

  Before using this product, the user must read and understand this document.  

  For additional information regarding this product, refer to the user guide and technical specifications. 

  All examples and diagrams are intended to aid understanding, and do not guarantee operation.  

Unitronics accepts no responsibility for actual use of this product based on these examples. 

  Please dispose of this product according to local and national standards and regulations. 

  Only qualified service personnel should open this device or carry out repairs. 

 

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.  

 

  Do not attempt to use this device with parameters that exceed permissible levels. 

  To avoid damaging the system, do not connect/disconnect the device when power is on. 

Environmental Considerations 

 

  Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,  

moisture or rain, excessive heat, regular impact shocks or excessive vibration. 

 

  Ventilation: 10mm space required between the PLC+HMI

s’ top/bottom edges & enclosure 

walls. 

  Do not place in water or let water leak onto the unit. 

  Do not allow debris to fall inside the unit during installation. 

 

Mounting 

Dimensions 

 

 

* Note that for JZ20-J modules those dimensions are 7.5 mm (0.295

”). 

 
 
 
 
 
 
 
 

Summary of Contents for Jazz JZ20-J-UN20

Page 1: ...ations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect the device when power is on Environmental Considerations Do not install in areas wi...

Page 2: ...ure Wiring This equipment is designed to operate only in SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V pin Do not touch live wires All wiring activities should be performed while power ...

Page 3: ...and noise interference with input lines used over an extended distance Use wire that is properly sized for the load Earthing the product To maximize system performance avoid electromagnetic interference as follows Use a metal cabinet Connect the 0V terminal directly to the earth ground of the system Use the shortest less than 1m 3 3 ft and thickest 2 08mm 14AWG min wires possible Inputs This model...

Page 4: ...In either case the npn pnp pins must be connected Input wiring npn sink Input wiring pnp source Input wiring I0 I8 pnp source I9 I10 npn sink Analog Inputs Note Shields should be connected at the signal source Analog Input wiring current 2 wire AN1 Analog Input wiring current 3 wire AN1 Analog Input wiring current 4 wire AN1 Analog Input wiring voltage AN2 and AN3 ...

Page 5: ...C 328 to 1400 F White Red Yellow Blue K 200 to 1250 C 328 to 2282 F Yellow Red Brown Blue N 200 to 1300 C 328 to 3214 F Orange Red Orange Blue R 0 to 1768 C 32 to 3214 F Black Red White Blue S 0 to 1768 C 32 to 3214 F Black Red White Blue T 200 to 400 C 328 to 752 F Blue Red White Blue Thermocouple 0 use T Input as negative input and T as positive RTD PT100 Sensor 0 use both inputs related to CM s...

Page 6: ...arily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no even...