MODEL IDENTIFICATION 

 

 

UTMD   

Contain the Siren only 

 

UTMD-MB 

Contains the Siren, Mounting Bracket and Microphone 

 

UTMD-AL 

Same as UTMD-AL with push buttons configured for latching. 

 

 
 
 
 
 

DIGITAL CIRCUITRY WARNING 

 

Some auto manufacturers have converted to Digital Park/Neutral reference signal. 

Refer to Federal Signal Corporation Service Bulletin No 9.; Dated 11/03/04.

 

On these vehicles, the Park/Neutral position can only be monitored with a 5-volt reference signal. 

Automobile manufacturers state that a 12 Volt or ground signal will result in damage to the vehicle starting system. 

If installation of a UPKM-1 is to be utilized, please check with Unitrol regarding compatibility issues. 

Federal Signal / Unitrol UPKM-2 is compliant with both digital and 12-volt systems. 

 
 
 
 

PANEL LIGHTING 

For satisfactory lighting, it is recommended that the panel 
lights (terminal #1) be connected to the vehicle light circuit 
as shown. 
 

SIREN DEACTIVATION 

The park kill feature of the Touchmaster 

Delta

 ™ uses the 

Neutral Safety Switch to stop all siren sounds except P.A., 
Alarm, and Radio Rebroadcast. The Neutral Safety Switch 
must be hooked up to the Park Kill input using Terminal 
#14. A Park Kill Module 

must

 be installed as an interface 

between the vehicle and the Touchmaster 

Delta

™.  

(The Park Kill Module is available at an extra cost). The 
Park Kill Module will protect both the vehicle and the 
Touchmaster 

Delta

™ from damage caused by transient 

voltages.  

See Digital Circuitry Warning

 

NOTE:

 

The only wire connected to Terminal #14 should 

be the GRAY wire of the UPKM-2.  When testing this 
feature, put the emergency brake on and verify siren 
sounds in Reverse and Drive and that there is no sound in 
Park or Neutral.

   

ALARM 

Applying a ground (-) to the ALARM terminal triggers the 
siren to a distinctive 2KHz sound.  This function may be used 
as a burglar alarm or a high-temperature alarm for K-9 carriers.  
A motion-detector or switches at the trunk, doors, etc. may be 
used for burglar alarms.  A temperature switch (Part # UTAS) 
is available at an extra cost for a temperature alarm.  A key 
switch or concealed On/Off switch must be installed in-line 
with the ALARM terminal. 
 

FOOTSWITCH 

A foot switch or any manual switch may be used in lieu of, or 
in addition to, the horn ring.  If the switch is used alone, 
connect one switch terminal to ground (-), and connect the 
other terminal to the RNG terminal.  If a switch is used in 
conjunction with the horn ring connections, connect one 
terminal to RNG, and the other to (-) or (+) to match the horn 
ring polarity. 
 

HORN RING CONNECTIONS 

Optional – Cut the vehicle horn circuit and connect the leads to 
the HRN and RNG terminals on the back of the Touchmaster 

SECTION IV 

INSTALLATION 

SIREN / P.A. CONNECTIONS

 

Summary of Contents for UTMD

Page 1: ...1 I N S T A L L A T I O N M A N U A L TOUCHMASTER DELTA SIREN PA SYSTEM UTMD UTMD MB UTMD AL FS UNITROL 1108 RAYMOND WAY ANAHEIM CA 92801 1 714 871 3336 FAX 1 714 871 3418 22 UTMD 00 ECO 104 06 MAN ...

Page 2: ...rranty period If such examination reveals a defect in material and or workmanship UNITROL UNITROL will complete the necessary repairs under warranty This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for removal and re installation of the product Lamps flash tubes or batteries are not covered under warranty Warranty wil...

Page 3: ...T E N T S SECTION TITLE PAGE I GENERAL INFORMATION 4 II SPECIFICATIONS 4 III SAFETY MESSAGE TO INSTALLERS 5 IV INSTALLATION 6 8 V LATCHING ACCESSORY SWITCHES 8 VI SAFETY MESSAGE TO OPERATORS 10 VII SERVICE AND MAINTENANCE 11 ...

Page 4: ...ratings Slide bar outputs progressive Position 1___________________________________20 amps Position 2___________________________________20 amps Position 3___________________________________20 amps Progressive total______________________________60 amps Push button switches__________________________20 amps each STANDARD SIREN SOUNDS The TM DELTA is shipped with 5 operational siren sounds MAN manual ...

Page 5: ...e Slide Switch outputs Terminal 15 16 and 17 Connect all power not ignition and ground wires directly to battery Implementing an in line switch will cause all accessory outputs to energize momentarily Devices such as gunlocks trunk release etc will be activated upon power being provided by such a switch Sound output will be severely reduced if any objects are in front of this speaker If maximum so...

Page 6: ...aster Delta The Park Kill Module is available at an extra cost The Park Kill Module will protect both the vehicle and the Touchmaster Delta from damage caused by transient voltages See Digital Circuitry Warning NOTE The only wire connected to Terminal 14 should be the GRAY wire of the UPKM 2 When testing this feature put the emergency brake on and verify siren sounds in Reverse and Drive and that ...

Page 7: ...7 TOP RELAY BOARD ...

Page 8: ...DE switch is in a siren position WAIL or YELP SECTION V FACEPLATE OPERATION CONFIGURATION SW1 SW2 SW4 SW3 SW6 SW5 TouchMaster Delta auxiliary push button switches Accessory switch connections provide a 12 volt output Hook the power connection of the auxiliary device to the terminal that corresponds to the switch output terminal that operator would like to activate See illustration on next page Swi...

Page 9: ...9 ...

Page 10: ...force your way through traffic Your emergency lights siren and actions are REQUESTING the right of way Although your warning system is operating properly it may not alert everyone People may not hear see or heed your warning signal You must recognize this fact and continue driving cautiously Situations may occur which obstruct your warning signal when natural or man made objects are between your v...

Page 11: ...p is available by phone 7 00 AM to 3 30 PM Pacific Standard Time Monday through Friday except holidays 800 854 3375 is toll free within the United States and Canada Phone 714 871 3336 from other areas If it is necessary to return a unit please observe this procedure a Call for RMA number b Pack to prevent damage in transit c Include brief description of problem and RMA No d Include name and phone ...

Reviews: