Page 1: ...1 I N S T A L L A T I O N M A N U A L TOUCHMASTER DELTA SIREN PA SYSTEM UTMD UTMD MB UTMD AL FS UNITROL 1108 RAYMOND WAY ANAHEIM CA 92801 1 714 871 3336 FAX 1 714 871 3418 22 UTMD 00 ECO 104 06 MAN ...
Page 2: ...rranty period If such examination reveals a defect in material and or workmanship UNITROL UNITROL will complete the necessary repairs under warranty This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for removal and re installation of the product Lamps flash tubes or batteries are not covered under warranty Warranty wil...
Page 3: ...T E N T S SECTION TITLE PAGE I GENERAL INFORMATION 4 II SPECIFICATIONS 4 III SAFETY MESSAGE TO INSTALLERS 5 IV INSTALLATION 6 8 V LATCHING ACCESSORY SWITCHES 8 VI SAFETY MESSAGE TO OPERATORS 10 VII SERVICE AND MAINTENANCE 11 ...
Page 4: ...ratings Slide bar outputs progressive Position 1___________________________________20 amps Position 2___________________________________20 amps Position 3___________________________________20 amps Progressive total______________________________60 amps Push button switches__________________________20 amps each STANDARD SIREN SOUNDS The TM DELTA is shipped with 5 operational siren sounds MAN manual ...
Page 5: ...e Slide Switch outputs Terminal 15 16 and 17 Connect all power not ignition and ground wires directly to battery Implementing an in line switch will cause all accessory outputs to energize momentarily Devices such as gunlocks trunk release etc will be activated upon power being provided by such a switch Sound output will be severely reduced if any objects are in front of this speaker If maximum so...
Page 6: ...aster Delta The Park Kill Module is available at an extra cost The Park Kill Module will protect both the vehicle and the Touchmaster Delta from damage caused by transient voltages See Digital Circuitry Warning NOTE The only wire connected to Terminal 14 should be the GRAY wire of the UPKM 2 When testing this feature put the emergency brake on and verify siren sounds in Reverse and Drive and that ...
Page 7: ...7 TOP RELAY BOARD ...
Page 8: ...DE switch is in a siren position WAIL or YELP SECTION V FACEPLATE OPERATION CONFIGURATION SW1 SW2 SW4 SW3 SW6 SW5 TouchMaster Delta auxiliary push button switches Accessory switch connections provide a 12 volt output Hook the power connection of the auxiliary device to the terminal that corresponds to the switch output terminal that operator would like to activate See illustration on next page Swi...
Page 9: ...9 ...
Page 10: ...force your way through traffic Your emergency lights siren and actions are REQUESTING the right of way Although your warning system is operating properly it may not alert everyone People may not hear see or heed your warning signal You must recognize this fact and continue driving cautiously Situations may occur which obstruct your warning signal when natural or man made objects are between your v...
Page 11: ...p is available by phone 7 00 AM to 3 30 PM Pacific Standard Time Monday through Friday except holidays 800 854 3375 is toll free within the United States and Canada Phone 714 871 3336 from other areas If it is necessary to return a unit please observe this procedure a Call for RMA number b Pack to prevent damage in transit c Include brief description of problem and RMA No d Include name and phone ...