To delete a (group of) channel(s), position the arrow on the
channel and press the rotary button 3
seconds.
DISPLAY READOUT
EXPLANATION
To delete a (group of) channel(s), position the arrow
on the channel and press the rotary button 3 seconds.
When you have added all the channels to INPUT VHF,
and you want to add channels to the other inputs,
scroll up to the top of the menu (to INPUT VHF), tap
the button and scroll to the next input.
Repeat the previous steps for all input channels.
OUTPUT
SETTINGS
DISPLAY READOUT
EXPLANATION
Define the OUTPUT LEVEL of the output signal.
Range between 88 dBµV and 108 dBµV. Check the
output via a network analyser on the -30dB test port.
Note: The more channels you select, the less input
power you should
give.
To compensate for cable losses, a VHF/DAB Attenuator
of up to 15 dB can be set to lower the VHF and DAB
output level (compared to the UHF output level). 0 dB
means all channels have the same output level (see
previous display readout), 15 dB means that VHF and
DAB are 15 dB lower than the chosen output level
above.
Note
: In the OUTPUT menu, you define the output level in dBµV of the MUXes. The Profino
Revolution Plus has enough gain to guarantee this output level under all input conditions. In
case a slope has been set, the output level indicated on the display will be the output level of
the highest frequency MUX.