Unitron Johansson 5951 User Manual Download Page 8

RMU (REF. 5951) - RMU SMART POWER SUPPLY (REF. 5952) 

 

 

 

 

 

8

 

 

 

 

 

Alarm: 

 

For setting alarm triggers go “Alarm” tab.

 

 

 

 

To select for which headends you want to receive an email with the alarm messages, go 

to the overview page en select alarms 

 

 

 

5.

 

R

EF 

5952:

 

B

ACK

-

UP 

P

OWER 

S

UPPLY

 

REF. 5952 should always be used 
in combination with a primary 
power supply REF. 5050W. 

In the case the primary power 
supply stops working, the REF. 
5952 back-up power supply will 
take over without interruption. 

Please take into account the 
power derating related to the 
ambient room temperature.

 

This should stay lower than 
50°C! 

 

 

Summary of Contents for Johansson 5951

Page 1: ...User Manual Remote Management Unit Ref 5951 5952 RMU REF 5951 RMU WITH INTEGRATED SMART POWER SUPPLY REF 5952...

Page 2: ...ENDIX ALARM AND MONITORING MESSAGES 11 Device info messages 11 General info messages 12 Warning messages 12 Error messages 13 No part of this manual may be copied reproduced transmitted transcribed or...

Page 3: ...ck mountable module very simple installation plug and play no network knowledge needed very cost efficient solution for remote monitoring and alarming REF 5952 intelligent backup power supply for redu...

Page 4: ...tilation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatu...

Page 5: ...E CLOUD Solid Green Solid red NOT CONNECTED TO THE CLOUD Blinking green Blinking red Reset Button Push the reset button firmly for 3 seconds Restart with IP release slow red blinking of Alarm LED Push...

Page 6: ...G THE RMU WITH UCLOUD 1 Go to https www ucloudserver com 2 Create an account and log in 3 When logged in click Digital Modular Headend 4 Add your remote system by clicking on New on the left side of t...

Page 7: ...7 4 ALARM AND MONITORING OPTIONAL For Alarm and Monitoring click on System in your headend Monitoring For Real time Monitoring go to Monitoring tab See appendix of this manual for overview of alarm l...

Page 8: ...overview page en select alarms 5 REF 5952 BACK UP POWER SUPPLY REF 5952 should always be used in combination with a primary power supply REF 5050W In the case the primary power supply stops working th...

Page 9: ...HTTP FTP DHCP LEDs 1 x alarm LED 1 x power LED Input Voltage from Primary PS VDC 15 RMU Consumption A 0 25 Operating Temperature C 20 to 50 Built in Back up Power Supply REF 5952 only Connector Power...

Page 10: ...the product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accesso...

Page 11: ...eName is available 12 Service serviceName is FTA 13 Service serviceName is pay TV scrambled 14 Service serviceName is pay TV unscrambled 15 Service serviceName is forwarded through CAM path 16 IP serv...

Page 12: ...ow 5 High input signal OK again on tuner subcode Signal level has again an acceptable level 6 Input signal high on tuner subcode Input signal is high 7 Input signal quality OK again on tuner subcode S...

Page 13: ...subcode 12 Input signal lost on tuner subcode Check if signal is connected and LNB powered when needed 13 Too low input signal solved on tuner subcode Signal level has gone from low level to acceptab...

Page 14: ...RMU REF 5951 RMU SMART POWER SUPPLY REF 5952 14 UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 sales unitrongroup com www unitrongroup com...

Reviews: