background image

18

19

   Program/volume control push button

If your hearing care professional has configured 

one hearing aid to be a program control and the 

other hearing aid to be a volume control:

• 

Push the button on your  

 

right / 

 

left 

hearing aid to access your different programs, 

and

• 

Push the button on your  

 

right / 

 

left 

hearing aid to step through your volume levels

On/off

Switch on hearing aid

The hearing aid is configured  

to switch on automatically  

when removed from the  

charger. If this function is not  

configured, firmly press and  

hold the button until the  

indicator light blinks.  Wait until the solid green 

light indicates the hearing aid is ready. 

Switch off hearing aid

Press and hold the button until the indicator 

light turns solid red, signifying that the hearing 

aid is switching off. 

The hearing aid is configured to switch off 

automatically when placed into the power-

connected charger.

Blinking green

Hearing aid is switching on

Solid red

Hearing aid is switching off

Summary of Contents for Blu Moxi B-RS

Page 1: ...MoxiTM B RS hearing aid guide Powered by Blu A Sonova brand ...

Page 2: ... RS FLEX TRIAL c SlimTip Charging accessory c Unitron Moxi RS charger If no box is checked and you do not know the model of your hearing aid or charging accessories please ask your hearing care professional The hearing aids described in this user guide contain a built in and non removable rechargeable lithium ion battery Please also read safety information regarding handling rechargeable hearing a...

Page 3: ...ccessories contact your hearing care professional or manufacturer representative Additional information can be found in the specification sheet of your product www unitron com Table of contents 1 Quick guide 2 2 Parts of the hearing aid and charger 4 3 Charging the hearing aids 8 4 Turning your hearing aids on and off 13 5 Putting your hearing aids on your ears 14 6 Operating instructions 16 Pairi...

Page 4: ... Multi function button Charging your hearing aids Place the hearing aids in the charger Charging Slow blinking indicator light Fully charged Solid green indicator light On Off Left right hearing aid markings L marking for left hearing aid R marking for right hearing aid Enter flight mode When the device is off keep pressing the button for 7 seconds The indicator light will first blink green and th...

Page 5: ...on button functions as an on off switch switches between listening programs changes the volume level and accepts or rejects mobile phone calls depending on your customized fitting 4 Wire connects the speaker unit to your hearing aids 5 Dome holds the speaker unit in place in your ear canal 6 Speaker unit amplifies the sound and sends it directly into the ear canal 7 Charging contacts Moxi B RS hea...

Page 6: ...Hearing aid charging inserts with left right indicators USB cable 3 m Power supply External power supply Power supply specification Power supply output voltage 5 VDC 10 current 1 A Charger input voltage 5 VDC 10 current 500 mA USB cable specifications 5 V min 1 A USB A to USB C maximum length 3 m ...

Page 7: ...ds Connecting the power supply a b d c 1 Insert the hearing aids into the charging inserts Make sure the left and right hearing aid markings match the indicators next to the charging inserts 2 The hearing aid s indicator light will show the charging state of the battery until the hearing aid is fully charged When fully charged the indicator light will remain on i e solid green light The charging p...

Page 8: ... green light indicates the hearing aid is ready To switch off the charger remove the power supply from the power outlet Indicator light Charging state Approximate charging times 0 10 11 80 30 min 25 60 min 50 90 min 75 81 99 100 3 h Low power You will hear two beeps when the battery is low You will have approximately 60 minutes before you have to charge the hearing aids this can vary depending on ...

Page 9: ...s temporarily solid green Off Indicator light is temporarily solid red When you turn your hearing aids on you may hear a start up melody On Off 5 Putting your hearing aids on your ears 1 Place the hearing aid behind your ear 2 Hold the wire where it attaches to the dome and gently push the dome into your ear canal The wire should lie flush against your head and not stick out 3 If there is a retent...

Page 10: ...g for left hearing aid R Red marking for right hearing aid 1 R 6 Operating instructions These instructions describe the default multi function button or tap control settings Your hearing care professional may change the functionality See your hearing care professional for more information Multi function button The multi function button has several functions It functions as an on off switch a volum...

Page 11: ...ise 2 beeps Program 3 e g telephone 3 beeps Program 4 e g music 4 beeps Volume control If your multi function button has been configured as a volume control either Pushthebuttononyourrighthearingaidto increasethevolume and Pushthebuttononyourlefthearingaidto decreasethevolume or Pushthebuttontostepthroughyourvolume levels As you change the volume your hearing aids will beep Volume setting Beeps Su...

Page 12: ...aid is configured to switch on automatically when removed from the charger If this function is not configured firmly press and hold the button until the indicator light blinks Wait until the solid green light indicates the hearing aid is ready Switch off hearing aid Press and hold the button until the indicator light turns solid red signifying that the hearing aid is switching off The hearing aid ...

Page 13: ...p control tap the top of your ear twice Connectivity overview The illustration below shows some of the connectivity options available for your hearing aids Mobile phone TV Connector connected to TV PartnerMic Please see the user guide that came with your accessory for more information Please contact your hearing care professional to get a TV Connector Remote Control PartnerMic or Roger accessories...

Page 14: ...dStates and certain other countries Android is a trademarkof Google LLC Pairing your mobile phone with your hearing aids 1 On your device i e phone go to your settings menu to ensure Bluetooth is on and search for Bluetooth enabled devices 2 Switch on both hearing aids Your hearing aids will remain in pairing mode for 3 minutes 3 Your device shows a list of Bluetooth enabled devices Select the hea...

Page 15: ... connected to up to two devices and paired to up to eight devices Phone calls Your hearing aids allow direct communication with Bluetooth enabled devices When paired and connected to a phone you will hear the caller s voice directly in your hearing aids Your hearing aids pick up your voice through their own microphones You do not need to hold your mobile phone close to your mouth your voice is tra...

Page 16: ...r voice is picked up by the hearing aid microphones and transmitted to the phone Accepting a mobile phone call When receiving a call an incoming call notification will be heard in the hearing aids The call can be accepted by tapping the top of your ear twice or with a short push of less than 2 seconds on the multi function button on either hearing aid Alternatively accept the call on your phone as...

Page 17: ...he multi function button on the hearing aid or directly on your phone long push 2 sec tap ear twice or Rejecting a phone call An incoming call can be rejected by a long press on the multi function button on either hearing aid for more than 2 seconds Alternatively reject the call directly on your phone long push 2 sec ...

Page 18: ... the hearing aid is turned off proceed to Step 2 If the hearing aid is on turn it off by pressing and holding the button until the indicator light turns solid red signifying that the hearing aid is switching off 2 Keep pressing the button for 7 seconds The indicator light will first blink green and then turn to solid orange indicating that the flight mode has been activated In flight mode your hea...

Page 19: ...ditions The product is designed such that it functions without problems or restrictions if used as intended unless otherwise noted in these user guides Please ensure to use charge transport and store the hearing aids according to the following conditions Use Charging Transport Storage Temperature Maximum range Recommended range 5 to 40 C 41 to 104 F 5 to 40 C 41 to 104 F 20 to 60 C 4 to 140 F 20 t...

Page 20: ...r liquids with a chemical content 8 Caring for your hearing aids Protecting your hearing aids Expected Service Life The hearing aids and the compatible charger have the expected service life of five years The devices are expected to remain safe for use for this duration Commercial service period Routine and diligent care of your hearing aids and charger will contribute to the outstanding performan...

Page 21: ...ap etc for cleaning your hearing aid It is not recommended to rinse with water If you need to clean your hearing aid intensively ask your hearing care professional for advice and information on filters or drying capsules Charger Makesurethatchargerinsertsareclean Neverusecleaningagentssuchashousehold detergents soap etc forcleaningyourcharger Weekly Hearing aid Clean the earpiece with a soft damp ...

Page 22: ... if it looks dirty or if the hearing aid volume or sound quality is reduced The earwax protection should be replaced every four to eight weeks on a regular speaker 1 Remove the dome from the speaker by holding the speaker in one hand and the dome in the other 2 Gently pull off the dome to remove 3 Clean the speaker with a lint free cloth 2 3 1 Speaker with dome Removing the dome from the speaker ...

Page 23: ...con 1 2 3 Exchanging the earwax protection with CeruShield Disk 3 To insert a new earwax protector carefully insert the speaker into the opening where the new earwax protector is visible opposite the bin icon until it clicks After the click you will see the opening below is empty and the new earwax protector is now inside the speaker 1 Hold the speaker in one hand and the dome in the other 2 Slide...

Page 24: ...volume control available see Chapter 6 10 Troubleshooting guide Cause Possible remedy Issue Hearing aid not loud enough or distorted Volume too low Increase volume if volume control available see Chapter 6 Low battery Charge hearing aid Speaker earpiece blocked Clean speaker opening earpiece Hearing has changed Contact you hearing care professional Issue Hearing aid plays two beeps Indication for ...

Page 25: ...ing aid up Operating temperature range is 5 to 40 Celsius 41 to 104 Fahrenheit Faulty battery Contact your hearing care professional Cause Possible remedy Issue Indicator light on hearing aid switches off when hearing aid is removed from charger Auto On feature is disabled Switch on the hearing aid Issue Indicator light on hearing aid remains solid green after removal from charger Indicator light ...

Page 26: ...he hearing care professional where you purchased your hearing aids and chargers about the terms of the local warranty International warranty Sonova AG offers a one year limited international warranty valid from the date of purchase This limited warranty covers manufacturing and material defects in the hearing aid and chargers respectively but not accessories such as tubes earpieces or external spe...

Page 27: ...ant safety information and limitations of use information on the following pages before using your hearing aid Intended use The intended use of hearing aids is to amplify and transmit sound to the ears and hereby compensate for impaired hearing The charger is an accessory to a medical device and has no therapeutic or diagnostic use on its own It is intended to charge the rechargeable hearing aids ...

Page 28: ...ing aids and Tinnitus feature are Presence of hearing loss Uni or bilateral Conductive sensorineural or mixed Mild to profound Presence of a chronic tinnitus only applicable for devices which provide the Tinnitus feature Contraindications General clinical contraindications for the use of hearing aids and Tinnitus software are Hearing loss is not in the fitting range of the hearing aid i e gain fre...

Page 29: ...ot appropriate or in the best interests of the patient when the following applies When there is sufficient evidence that the condition has been fully investigated by a medical specialist and any possible treatment has been provided The condition has not worsened or changed significantly since the previous investigation and or treatment If the patient has given their informed and competent decision...

Page 30: ...ded purpose Side effects Physiological side effects of hearing aids like tinnitus dizziness wax build up too much pressure sweating or moisture blisters itching and or rashes plugged or fullness and their consequences like headache and or ear pain may be resolved or reduced by your hearing care professional Conventional hearing aids have the potential to expose patients to higher levels of sound e...

Page 31: ...resolved or improved during the fine tuning process at the fitting procedure by your hearing care professional Any serious incident that has occurred in relation to the device should be reported to the manufacturer representative and the competent authority of the state of residence The serious incident is described as any incident that directly or indirectly led might have led or might lead to an...

Page 32: ...mmed for each hearing loss must only be used by the intended person They should not be used by any other person as they could damage hearing Changes or modifications to the hearing aid that were not explicitly approved bySonova AG are not permitted Such changes may damage your ear or the hearing aid Do not use the hearing aids and charging accessories in explosive areas mines or industrial areas w...

Page 33: ...ollowing is only applicable for persons with active implantable medical devices i e pacemakers defibrillators etc Keep the wireless hearing aid at least 15 cm 6 inches away from the active implant If you experience any interference do not use the wireless hearing aids and contact the manufacturer of the active implant Please note that interference can also be caused by power lines electrostatic di...

Page 34: ...ot be valid anymore in your country please refer to IEC 62368 1 Do not touch the contacts of the charger when powered Hearing aids should not be fitted with domes wax protection systems when used by clients with perforated eardrums inflamed ear canals or otherwise exposed middle ear cavities In these cases we recommend the use of a custom earpiece In the unlikely case that any part of this product...

Page 35: ...ntact the hearing care professional Product safety These hearing aids are water resistant and not waterproof They are designed to withstand normal activities and occasional accidental exposure to extreme conditions Never immerse your hearing aid in water These hearing aids are not specifically designed for extended periods of water submersion on a continual basis that is worn in activities such as...

Page 36: ... must be protected against shocks If the charger or power supply is damaged after a shock the devices must not be used anymore Make sure that you always completely dry your hearing aid after use Store the hearing aid in a safe dry and clean place Special medical or dental examination including radiation described below may adversely affect the correct functioning of your hearing aids Remove and ke...

Page 37: ...e phone emissions For example the sum of the hearing aid rating of 4 M4 and a telephone rating of 3 M3 would result in a combined rating of 7 Any combined rating that equals at least 5 would provide normal use a combined rating of 6 or greater would indicate excellent performance The immunity of these hearing aids is at least M4 The equipment performance measurements categories and system classifi...

Page 38: ...with the tinnitus masker are to be fitted by a hearing care professional familiar with the diagnosis and management of tinnitus Should you develop any side effects while using the tinnitus masker such as headaches nausea dizziness or heart palpitations or experience a decrease in auditory function such as decreased loudness tolerance worsening of tinnitus or speech not as clear you should disconti...

Page 39: ...ct including accessories meets the requirements of the Medical Devices Regulation EU 2017 745 as well as the Radio Equipment Directive 2014 53 EU The numbers after the CE symbol correspond to the code of certified institutions that were consulted under the above mentioned regulation and directive This symbol indicates that the products described in these user instructions adhere to the requirement...

Page 40: ...n conformity assessment requirements for equipment under health surveillance system OCP indicates the certification body Japanese markfor certified radio equipment Indicates the date when the medical device was manufactured Indicates the manufacturer s serial number so that a specific medical device can be identified Indicates the manufacturer s catalogue number so that the medical device can be i...

Page 41: ...laration of conformity Hereby Sonova AG declares that this product meets the requirements of the Medical Devices Regulation MDR2017 745 and complies with Radio Equipment Directive 2014 53 EU The full text of the EU Declaration of Conformity can be obtained from the manufacturer via the following web address www sonova com en certificates Australia New Zealand Indicates a device s compliance with a...

Page 42: ...If this device does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the device into an outlet on a circuit different fr...

Page 43: ...y of the ear ii History of active drainage from the ear within the previous 90 days iii History of sudden or rapidly progressive hearing loss within the previous 90 days iv Acute or chronic dizziness v Unilateral hearing loss of sudden or recent onset within the previous 90 days vi Audiometric air bone gap equal to or greater than 15 decibels at 500 hertz Hz 1 000 Hz and 2 000 Hz vii Visible evide...

Page 44: ...sed physician Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician The exercise of such a waiver is not in your best health interest and its use is strongly discouraged Children with hearing loss In addition to seeing a physician for a medical evaluation a child with a he...

Page 45: ...84 85 ...

Page 46: ...ewood Place Norwest NSW 2153 Australia And importer for European Union Sonova Deutschland GmbH Max Eyth Str 20 70736 Fellbach Oeffingen Germany Pat www sonova com en intellectualproperty For a listing of Unitron group companies please visit www unitron com ...

Page 47: ...Distributor unitron com 029 6649 02 V2 0 2022 03 TM 2021 Sonova AG All rights reserved Manufacturer Sonova AG Laubisrütistrasse 28 CH 8712 Stäfa Switzerland 7 6 1 3 3 8 9 5 4 3 3 7 7 ...