Unitron 9732 User Manual Download Page 8

dCSS/dSCR Multiswitch (Ref. 9732) v1.0 

 

 

 

 

 

8

 

 

 

 

5.

 

C

ONDITIONS OF WARRANTY

 

Unitron N.V. warrants the product as being free from defects in material and  

workmanship for a period of 24 months starting from the date of production indicated on 
it. See note below. 

If during this period of warranty the product proves defective, under normal use, due to 
defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the 
product. Return the product to your local dealer for reparation 

THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP 
AND DOES NOT COVER DAMAGE RESULTING FROM: 

 

Misuse or use of the product out of its specifications.

 

 

Installation or use in a manner inconsistent with the technical or safety standards  in 
force in the country where the product is used

 

 

Use of non-suitable accessories (power supply, adapters...).    

 

Installation in a defect system. 

 

External cause beyond the control of Unitron N.V. such as drop, accidents, 
lightning, water, fire, improper ventilation… 

THE WARRANTY IS NOT APPLIED IF 

 

Production date or serial number on the product is illegible, altered, deleted or 
removed.

 

 

The product has been opened or repaired by a non-authorized person.

 

NOTE

 

Date of production is YYWW format, example 1447 = year 2014 – week 47. 
For the serial number barcodes, the date corresponds to the 4 first numbers 

 

 

 

 

 

 

UNITRON NV 
Frankrijklaan 27 

B-8970 Poperinge 
Belgium 

T +32 57 33 33 63 
F +32 57 33 45 24 

[email protected]

 

www.johansson.be 

Summary of Contents for 9732

Page 1: ...User Manual dCSS dSCR Multiswitch 9732 ...

Page 2: ...8 No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Specifications are subject to change without notice 3 16 Unitron F...

Page 3: ...dCSS dSCR Multiswitch Ref 9732 v1 0 3 1 INSTALLATION OF THE HARDWARE ...

Page 4: ...ansponder 101 Frequency 12731 Horizontal placed in output IF 2131 CSS Mode ONLY EN50494 SCR standard For Installation with Legacy STB and PVR MySKYHD SCR compatible Max 4 User Bands UB1 to UB4 available as in the LNB SCR Signalling DiSEqC 1 0 ONLY EN50607 dCSS standard For NEW Installation of HMG 12 User Bands for HMG in the range from UB5 to UB16 Signalling DiSEqC 1 0 or 2 0 CONCURRENT EN50494 EN...

Page 5: ...CSS dSCR UBs 16 16 dCSS dSCR output level 85 dBµV Return loss 8 dB Typ 12 dB Tap loss Not applicable AGC automatic Gain control Band and polarity selection DiSEqC 1 0 unidirectional DiSEqC 2 0 bidirectional Standard EN 50494 SCD Standard EN 50607 SCD 2 SKY UK standard Max DC current consumption 320mA 13 Volt Power supply From STB power inserter or trunk VL Power inserter 2460 9669 available separa...

Page 6: ... 9 1340 46 EN50607 10 1485 46 EN50607 11 1550 46 EN50607 12 1615 46 EN50607 13 1745 46 EN50607 14 1810 46 EN50607 15 1875 46 EN50607 16 1940 46 EN50607 UB index UB center frequency MHz UB default BW MHz 3 1680 46 SKY UK 9 1280 46 SKY UK 11 1380 46 SKY UK 14 1480 46 SKY UK 15 980 46 SKY UK 16 1030 46 SKY UK 17 1080 46 SKY UK 18 1130 46 SKY UK 19 1530 46 SKY UK 20 1580 46 SKY UK 21 1630 46 SKY UK 22...

Page 7: ...ation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of electric...

Page 8: ...product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF P...

Reviews: