Unitron 9732 User Manual Download Page 4

dCSS/dSCR Multiswitch (Ref. 9732) v1.0 

 

 

 

 

 

4

 

 

 

 

2.

 

C

ONFIGURATION OF THE MODULE

 

Installation Mode 

The device starts up in installation mode to check the equipment functionality and the correct 

installation. In this mode the automatic gain control is frozen (commands for activating the 
AGC are required). The multiswitch switches to SCR/CSS mode upon receiving a DiSEqC 
message. 

To activate one or more of the UBs a proper DiSEqC message should be received. 

The installation mode starts up with the following 2 transponders active (both output signals 

are having a fixed gain): 

 

Transponder 58 (Frequency: 11880 Vertical) placed in output IF 1281. 

 

Transponder 101 (Frequency: 12731 Horizontal) placed in output IF 2131. 

 

CSS Mode 

ONLY EN50494/SCR standard 

For Installation with Legacy STB and PVR/MySKYHD SCR compatible: 

 

Max 4 User Bands (UB1 to UB4) available (as in the LNB SCR) 

 

Signalling DiSEqC 1.0 

ONLY EN50607/dCSS standard 

For NEW Installation of HMG: 

 

12 User Bands for HMG in the range from UB5 to UB16 

 

Signalling DiSEqC 1.0 or 2.0 

CONCURRENT EN50494/EN50607 standards 

For existing MULTIVISION installations (Legacy STB/PVR SCR compatible), with main STB 
upgraded to Next Gen PVR/HMG: 

 

Max 4 User Bands (UB1 to UB4) available for current STB/PVR 

 

12 User Bands for HMG in the range from UB5 to UB16 

 

Signalling DiSEqC 1.0 + signalling DiSEqC 2.0 in the same cable from LNB to apartment 

SKY UK standard 

For Installations with SKY Q-Box : 

 

16 User bands in SCR mode 

 

Signalling DiSEqC 1.0 or 2.0 

 

Summary of Contents for 9732

Page 1: ...User Manual dCSS dSCR Multiswitch 9732 ...

Page 2: ...8 No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Specifications are subject to change without notice 3 16 Unitron F...

Page 3: ...dCSS dSCR Multiswitch Ref 9732 v1 0 3 1 INSTALLATION OF THE HARDWARE ...

Page 4: ...ansponder 101 Frequency 12731 Horizontal placed in output IF 2131 CSS Mode ONLY EN50494 SCR standard For Installation with Legacy STB and PVR MySKYHD SCR compatible Max 4 User Bands UB1 to UB4 available as in the LNB SCR Signalling DiSEqC 1 0 ONLY EN50607 dCSS standard For NEW Installation of HMG 12 User Bands for HMG in the range from UB5 to UB16 Signalling DiSEqC 1 0 or 2 0 CONCURRENT EN50494 EN...

Page 5: ...CSS dSCR UBs 16 16 dCSS dSCR output level 85 dBµV Return loss 8 dB Typ 12 dB Tap loss Not applicable AGC automatic Gain control Band and polarity selection DiSEqC 1 0 unidirectional DiSEqC 2 0 bidirectional Standard EN 50494 SCD Standard EN 50607 SCD 2 SKY UK standard Max DC current consumption 320mA 13 Volt Power supply From STB power inserter or trunk VL Power inserter 2460 9669 available separa...

Page 6: ... 9 1340 46 EN50607 10 1485 46 EN50607 11 1550 46 EN50607 12 1615 46 EN50607 13 1745 46 EN50607 14 1810 46 EN50607 15 1875 46 EN50607 16 1940 46 EN50607 UB index UB center frequency MHz UB default BW MHz 3 1680 46 SKY UK 9 1280 46 SKY UK 11 1380 46 SKY UK 14 1480 46 SKY UK 15 980 46 SKY UK 16 1030 46 SKY UK 17 1080 46 SKY UK 18 1130 46 SKY UK 19 1530 46 SKY UK 20 1580 46 SKY UK 21 1630 46 SKY UK 22...

Page 7: ...ation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of electric...

Page 8: ...product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF P...