Performance of Measurements / Performance of Cable Lengths Measurements

+

Store REF

The ''Store REF'' key is used to save the previously
set reference cable length.
The ''Store REF'' is only activated when the "Shift”
key is pressed at the same time.

[Arrow up]

The [arrow up] key together with the [arrow down]
key are used to set the reference cable lengths with-
in the reference range.

Store

The ''Store'' key is used to save a measurement re-
sult. If several measurement values have been cu-
mulated within the cumulative data memory, the
sum can be imported into the data memory by
pressing the ''Store'' key.

+

Clear one

''Clear one'' is pressed to clear the last measure-
ment value saved. The cumulative data memory is
not affected. The ''Clear one '' key is only activated
when the "Shift” key is pressed at the same time.

6.0  Performance of Measurements
6.1  Performance of Cable Lengths 

Measurements

• 

The leads to be measured must be positioned next
to each other. It is not possible to measure indi-
vidual wires. 

• 

For coaxial cable measurements, connect the in-
ternal conductors to the read sockets and the
sheath to the black socket.

• 

Only connect one lead per measurement connec-
tion.

• 

Additional measurement errors up to 10 % read-
ing may occur due to the differing cable structure
and material, depending on the manufacturer.

"

Switch on the UNITEST Echometer pressing the

key.

"

Connect the red test lead to the red socket and
the black test lead to the black socket of the m
range.

"

Connect two parallel leads of the cable to be
measured using the alligator clamps.

"

To set the desired measurement unit (m/ft),
press the 

und

key. ''m'' or

''ft'' is displayed. 

"

Set the measurement range selection dial in ac-
cordance with the conductor types in Table I or
II. The

key is used to switch to the mea-

surement ranges of table II. "TAB II” appears on
the display.

If the message ''- - -'' is displayed, the UNITEST
Echometer is ready to perform measurements.

"

Start measurement using the

key.

A single signal sound is audible and the mea-
surement value of the conductor length in the
pre-selected unit (m/ft) is displayed.

It is preferable to carry out the measurement
with open cable ends. If the cable end has a
short-circuit the message COMP is displayed.
Short-circuited cable ends cause an increasing
measurement error of the UNITEST Echometer
3000.

Start/Off

m/ft

m/ft

Shift

Start/Off

Shift

Shift

m

m

Echometer

6

29

Summary of Contents for Echometer 3000

Page 1: ...UNITEST Echometer 3000 Bedienungsanleitung Best Nr 2006 Instruction Manual Cat No 2006 Mode d emploi R f 2006 Manual de instrucciones No de ref 2006...

Page 2: ...Kabeltypen 10 6 2 2 L schen von Referenzbereichen 10 6 3 Fehlersuche 11 6 4 Durchf hren von Widerstandsmessungen Durchgangspr fungen 11 7 0 Interner Messwertspeicher Summenwertspeicher 12 7 1 Speiche...

Page 3: ...messger te Sie wurden nach den neuesten Sicherheitsvorschriften gebaut und ge w hrleisten ein sicheres und zuverl ssiges Arbei ten Die UNITEST Echometer sind im handwerkli chen industriellen oder im H...

Page 4: ...Anleitung beachten Die Bedienungsanleitung enth lt Informatio nen und Hinweise die zu einer sicheren Bedie nung und Nutzung des Ger tes notwendig sind DasGer tdarfinkeinemMessbereichanSpan nung gelegt...

Page 5: ...sbreitungs geschwindigkeit wiederum wird bestimmt durch die Beschaffenheit und den Aufbau d h jedes Kabel hat eine bestimmte charakteristische Ausbrei tungsgeschwindigkeit und somit unterschiedliche L...

Page 6: ...EST Echometer 3000 gespeicherten Werte zum PC gestartet Clear all Clear all l scht den gesamten internen Speicher Der Summenwertspeicher wird nicht gel scht Die Taste Clear all wird nur durch gleichze...

Page 7: ...lie en Durch die Unterschiede im Aufbau und Material der Kabel von den verschiedenen Herstellern k n nen zus tzliche Messfehler bis ca 10 v M ent stehen UNITEST Echometer mit der Taste einschalten Rot...

Page 8: ...1200 m 11 NYM J 4x10 mm2 1200 m 12 NYM J 5x10 mm2 1200 m 13 NYM J 4x16 mm2 1200 m 14 NYM J 5x16 mm2 1200 m 15 NYY J 3x1 5 mm2 1200 m 16 NYY J 4x1 5 mm2 1200 m 17 NYY J 5x1 5 mm2 1200 m 18 NYY J 3x2 5...

Page 9: ...TV 0 4 2 0 ALG 1900 m 16 Cable TV A 2YOK2YlnKx 2 2 8 8 A 2YOK2YlqKx 3 3 13 5 2000 m 17 TV 0632 75vz 1500 m 18 TV 0938 60vz 1600 m 0637 75bl 0637 75vz 0637 75vs 0632 75bl 19 TV 1046 75bl 1900 m 20 RG6...

Page 10: ...e des Referenzkabels speichern Es ert nt ein ein facher Signalton Notieren Sie sich den Kabeltyp die Schalterstellung sowie die Referenzebene Nun kann die L ngenmessung des eingemessenen Kabeltyps wie...

Page 11: ...gnalton und in der An zeige erscheint der Messwert der Leitungsl n ge bis zur Fehlerstelle in der vorgew hlten Ein heit m ft Erscheint zus tzlich die Anzeige COMP sind die Adern kurzgeschlossen Messun...

Page 12: ...belegte Speicherplatz z B nach L schen der Messung Nr 5 erscheint kurz eine 4 auf der Anzeige DerSummenwertspeicherwirddurchdieL schung nicht beeinflusst 7 2 Addieren und Speichern von Messergebnissen...

Page 13: ...rd unser Werksservice Ihr Ger t unverz glich wieder instandsetzen 9 1 Reinigung Sollte das Ger t durch den t glichen Gebrauch schmutziggewordensein kannesmiteinemfeuch ten Tuch und etwas mildem Hausha...

Page 14: ...m erh hten Messfehler Widerstand 0 2000 Ohm Aufl sung 0 1 Ohm Toleranz 2 v M 5 Digit Durchgang 10 Ohm Pr fstrom ca 1 mA Umgebungsbedingungen Betriebstemperatur 0 40 C 0 70 rel Luftfeuchte Lagertempera...

Page 15: ...UNITEST Echometer 3000 Instruction Manual Cat No 2006 Mode d emploi R f 2006 Manual de instrucciones No de ref 2006...

Page 16: ...tion of Customer Specific Cable Types 24 6 2 2 Deletion of Reference Ranges 24 6 3 Trouble Shooting 25 6 4 Performance of Resistance Measurements Continuity Tests 25 7 0 Internal Data Memory Cumulativ...

Page 17: ...a leading enterprise for test and measurement in struments The UNITEST Echometers are universally usable cable length measurement instruments They have been built in compliance with the most recent p...

Page 18: ...must comply with the safety references contained in this instruction manual Never apply voltage to any of the instrument measurement ranges Always verify that the circuits are not live using a dual po...

Page 19: ...ocity of the travelling pulse In turn the dispersion velocity is determined by the make and structure of a cable This means that every cable has a certain characteristic dispersion velocity and thus d...

Page 20: ...ter feet Send The Send key is used to start the transfer of the data memorised in the UNITEST Echometer 3000 to the PC Clear all Clear all deletes the total internal memory The cumulative data memory...

Page 21: ...ets and the sheath to the black socket Only connect one lead per measurement connec tion Additional measurement errors up to 10 read ing may occur due to the differing cable structure and material dep...

Page 22: ...YM J 5x6 mm2 1200 m 11 NYM J 4x10 mm2 1200 m 12 NYM J 5x10 mm2 1200 m 13 NYM J 4x16 mm2 1200 m 14 NYM J 5x16 mm2 1200 m 15 NYY J 3x1 5 mm2 1200 m 16 NYY J 4x1 5 mm2 1200 m 17 NYY J 5x1 5 mm2 1200 m 18...

Page 23: ...4 1 75 ALG 1800 m 15 Cable TV 0 4 2 0 ALG 1900 m 16 Cable TV A 2YOK2YlnKx 2 2 8 8 A 2YOK2YlqKx 3 3 13 5 2000 m 17 TV 0632 75vz 1500 m 18 TV 0938 60vz 1600 m 0637 75bl 0637 75vz 0637 75vs 0632 75bl 19...

Page 24: ...ble pressing and keys A simple signal sound is audible Note cable type switch position and reference level Now the length measurement of the cable type cal ibrated can be performed as described in sec...

Page 25: ...easurement pressing the key A single signal sound is audible and the mea surement value of the conductor length in the pre selected unit m ft up to the error location is displayed If the message COMP...

Page 26: ...and the last assigned memory location is briefly displayed E g After deleting measurement no 5 the number 4 is briefly displayed The cumulative data memory is not affected by the clearing procedure 7...

Page 27: ...such as UUT control instruments etc Never use acid detergents or dissolvants for clean ing 9 2 Battery Replacement Priortobatteryreplacement disconnectthein strument from all test leads connected Onl...

Page 28: ...tion Battery status display Battery symbol is dis played Auto power off after approx 5 min Power supply 1 x 9 V IEC 6LR61 Current consumption 25 mA max 75 mA Display light Dimensions 193 x 91 x 50 mm...

Page 29: ...UNITEST Echometer 3000 Mode d emploi R f 2006 Manual de instrucciones No de ref 2006...

Page 30: ...ifiques l usager 38 6 2 2 Supprimer les plages de r f rence 38 6 3 Localisation d erreurs 39 6 4 R alisation des mesures de r sistance des tests de continuit 39 7 0 M moire interne de donn es de mesur...

Page 31: ...plus r centes et assurent des mesures fiables et en toute s curit Tous les chom tres UNITEST pr sentent un support pr cieux pour les applications industrielles et professionnelles lors de mesures de c...

Page 32: ...de d un testeur de tension bipolaire par exemple UNITEST 2000 alpha Avant toute mesure s assurer du parfait tat de l appareil et des cordons de mesure Les instructions pr ventives mises par les caiss...

Page 33: ...du c ble En re tour cette vitesse est d termin e par la composi tion et la structure Ceci signifie que chaque c ble poss de une vitesse caract ristique de propagation d termin e et ainsi des dur es d...

Page 34: ...he Send sert d marrer la transmission des donn es m moris es dans la m moire de l chom tre UNITEST 3000 l ordinateur Clear all Clear all sert supprimer compl tement la m moire int gr e La m moire de d...

Page 35: ...et la gaine la borne noire Ne relier qu un fil par connexion de mesure Dues aux diff rences de composition et de mat riel des c bles des diff rents producteurs des er reursdemesuresuppl mentairesjusqu...

Page 36: ...0 NYM J 5x6 mm2 1200 m 11 NYM J 4x10 mm2 1200 m 12 NYM J 5x10 mm2 1200 m 13 NYM J 4x16 mm2 1200 m 14 NYM J 5x16 mm2 1200 m 15 NYY J 3x1 5 mm2 1200 m 16 NYY J 4x1 5 mm2 1200 m 17 NYY J 5x1 5 mm2 1200 m...

Page 37: ...1 75 ALG 1800 m 15 C ble TV 0 4 2 0 ALG 1900 m 16 C ble TV A 2YOK2YlnKx 2 2 8 8 A 2YOK2YlqKx 3 3 13 5 2000 m 17 TV 0632 75vz 1500 m 18 TV 0938 60vz 1600 m 0637 75bl 0637 75vz 0637 75vs 0632 75bl 19 TV...

Page 38: ...de r f rence l aide de la touche et de la touche Unsimple signal acoustique est audible Noter le type de c ble la position du s lecteur et le niveau de r f rence Maintenant la mesure de longueur du ty...

Page 39: ...de la touche Un simple signal sonore est audible et la valeur mesur e de la longueur du c ble jusqu l em placement de la faute appara t en affichant l unit de mesure pr s lectionn e m ft Si les embou...

Page 40: ...vement affi ch Parexemple Apr slasuppressiondelamesureno 5 le num ro 4 est bri vement affich La m moire de donn es cumul es n est pas in fluenc e par cette proc dure de suppression 7 2 Additionner et...

Page 41: ...et d connect de toute source de tension ex terne et de tout autre instrument connect comme par exemple l objet mesurer des instruments de contr le etc Ne jamais utiliser de d tergent acide ni de solv...

Page 42: ...es d termination de longueur Indication de la condition de pile affichagedusymboledepile Extinction automatique apr s env 5 min Alimentation par pile 1 x 9 V IEC 6LR61 Consommation 25 mA maxi 75 mA Il...

Page 43: ...UNITEST Echometer 3000 Manual de instrucciones No de ref 2006...

Page 44: ...tipos esp cificos de cables comunes al usuario 50 6 2 2 Borrar referencias 50 6 3 Detecci n de defectos 53 6 4 Medici n de resistencia prueba de continuidad 53 7 0 Memoria interna de valores medidos...

Page 45: ...o Ellos han sido construidos de acuerdo a las reglamentaciones de seguridad ac tuales y por ello se garantiza una utilizaci n segura y confiable Los ec metros UNITEST son de extrema ayuda tanto en el...

Page 46: ...ual de instrucciones El manual de instrucciones contiene informa ciones y advertencias que son necesarias para un manejo y utilizaci n libre de riesgos del equipo El instrumento no debe ser conectado...

Page 47: ...e desplazan por el cable A su vez la velocidad de propagaci n est determi nada por la estructura y construcci n es decir que cada cable tiene una cierta velocidad de propaga ci n caracter stica y por...

Page 48: ...Selecci n de la magnitud a utilizar metros pies send Con la tecla Send se inicia la transmisi n de datos archivados en el ec metro 3000 de UNITEST al or denador Clear all Clear all borra toda la memor...

Page 49: ...abajaconcablescoaxiales conectarelcon ductor interno a la entrada roja y la capa exterior a la negra Conectar solamente un hilo por conexi n Debido a las diferencias en la construcci n y ma terial de...

Page 50: ...m 10 NYM J 5x6 mm2 1200 m 11 NYM J 4x10 mm2 1200 m 12 NYM J 5x10 mm2 1200 m 13 NYM J 4x16 mm2 1200 m 14 NYM J 5x16 mm2 1200 m 15 NYY J 3x1 5 mm2 1200 m 16 NYY J 4x1 5 mm2 1200 m 17 NYY J 5x1 5 mm2 120...

Page 51: ...ALG 1800 m 15 Cable TV 0 4 2 0 ALG 1900 m 16 Cable TV A 2YOK2YlnKx 2 2 8 8 A 2YOK2YlqKx 3 3 13 5 2000 m 17 TV 0632 75vz 1500 m 18 TV 0938 60vz 1600 m 0637 75bl 0637 75vz 0637 75vs 0632 75bl 19 TV 1046...

Page 52: ...la perilla como tambi n el lugar de referencia Ahora se podr continuar con la medici n del tipo de cable reci n ingresado como se describe en el cap tulo 6 1 La precisi n de la medida de longitud dep...

Page 53: ...Se escuchar una se al ac stica y en el visua lizador aparecer el valor de longitud medido enlamagnitudseleccionada m ft Siadem s aparece el s mbolo COMP significa que los hilos est n puenteados La med...

Page 54: ...r las teclas y Se escuchar una se al ac stica y aparecer bre vementela ltimacategor adondehayarchivadoun resultado P ej Luego de borrar el resultado n 5 aparecer brevemente el 4 en el visualizador La...

Page 55: ...ante la vigencia de la garant a o despu s nuestro servicio t cnico reparar de inmediato su instru mento 9 1 Limpieza Si el instrumento se llegara a ensuciar por el uso co tidiano se lo podr limpiar co...

Page 56: ...prueba 1 mA aprox Condiciones ambientales Temperatura de funcionamiento0 40 C 0 70 humedad relativa ambiente Temperatura de almacenamiento 20 60 C 0 80 humedad relativa ambiente Altura sobre el nivel...

Page 57: ...57 Espanol...

Page 58: ...58...

Page 59: ...s soumis un contr le technique permanent Ces m mes quipements de contr le sont calibr s r guli rement l aide d appareils de r f rence calibr s selon les di rectives et normes en vigueur dans les labor...

Page 60: ...Elektrotechnik In den Engematten 14 79286 Glottertal Germany Tel 49 0 76 84 80 09 0 Fax 49 0 76 84 80 09 410 Techn Hotline 49 0 76 84 80 09 429 internet http www beha com e mail info beha de Reg No 33...

Reviews: