ENGLISH
12
USE
HOW TO CONNECT THE ACCES-
SORIES
Make sure that the appliance is di-
sconnected from the mains socket.
Attach the connector (C) to the
heater as follows:
Hook the socket flap on to the
lower hook of the connector.
Pull the flap well open.
Insert the connector into the socket
until it clicks into place.
Press the button to unlock and
extract the connector.
CABLE REWIND
Turn the steam generator as shown
in the diagram in order to rewind the
cable inside the coiler. Fasten the
cable terminal with the special lock.
HANDLE
This is attached to the heater by
means of the connector (C) and
enables all the cleaning accessories
to be attached. The grip has a button
for the distri bution of steam (S)
and a safety lock. To block or release
distribution of the steam use the
button positioned on the side of the
grip. The lock and release position
is indicated in the icon positioned
on this grip. The push-button for
delivering steam is a low voltage
(12V) switch. The handle is provided
with a selector for steam level. Select
the wished steam level, than push
the button (S) to relase steam. 1 =
low - 2 = middle - 3 = max
HOT WATER (only on 902DW and
903DW models)
The handle is provided with an “HOT
WATER” functionality, activated by a
low voltage switch on the left side of
the handle: push the switch (H) to ‘I’
mode to activate this functionality,
then push the button (S) to release
both steam and hot water.
EXTENSIONS
These are connected to the handle
so that the work field is widened.
The extensions have the same
attachment.
H
Summary of Contents for C201A
Page 2: ......
Page 7: ...7 ITALIANO...
Page 15: ...ENGLISH 15...
Page 23: ...23 FRAN AIS...
Page 31: ...31 DEUTSCH...
Page 39: ...39 ESPA OL...
Page 47: ...47 PORTUGUES...
Page 55: ...55 NEDERLANDS...
Page 59: ......