![Unitek TV3.230 Series Manual Download Page 16](http://html1.mh-extra.com/html/unitek/tv3-230-series/tv3-230-series_manual_4039349016.webp)
Transistor-Servo-Drive TV3.230
16
The connecting advices are for general information and without
obligation
Notice:
- Connecting- and operating instructions
- Local regulations
- EU-machine regulation
connection-No. clamps-plugs
X1: 1 up to X1:7 and X2 : 8 up to X2 : 14
Signal lines
Shielded and seperated from power lines.
nominal values paired twisted and shielded.
Logical connections
relay with gold contacts or reed relays. Contact current 6mA.
Enable -internal logical voltage
- internal logical voltage
X1:1
+15V/10mA
- contact chain between
X1:1 and X1:2
Enable -external logical voltage
- enable v10 ... +30V
X1:2
- GND
X1:7
Switch on enable
- nominal value and speed controller are enabled immediately.
Switch off enable
- quick stop
- nominal value
>>>
is switched internally immediately to 0
- after 2 seconds
>>>
speed controller is locked.
Mains failure- breaking
breaking function
-switch nomianl value in case of mains failure to 0V
-breaking time max. 150ms
generatoric rear feed into intermediate circuit
C
o
n
n
e
ct
io
n