CHAPTER 3: WELDING SYSTEM SET-UP
MODEL HF2 2 kHz HIGH FREQUENCY RESISTANCE WELDING POWER SUPPLY
3-16
990-057
11
Press [PROGRAM] twice to select the
Alphanumeric PROGRAM screen for
Schedule 2.
12
Verify that NEXT: 001 is correctly
displayed so that Schedule 2 will
automatically advance to Schedule 1
after one weld has been completed. If
you want to make more than one weld
using Schedule 2 before advancing to
Schedule 1, change STEP : 00001 to the
desired number of welds.
13
Press [SAVE] to save the updated Schedule 2.
14
Press [
W
] to select SCH:001 BASIC WELD.
15
Press [PROGRAM] once to select the Alphanumeric PROGRAM screen for Schedule 1.
16
Select NEXT: 001. Change 001 to 002
so that Schedule 1 will automatically
advance to Schedule 2 after one weld
has been completed. If you want to
make more than one weld using
Schedule 1 before advancing to
Schedule 2, change STEP : 00001 to the
desired number of welds.
17
Press [SAVE] to save the updated Schedule 1. Press [CHNG] to return to the Weld Graph
RUN State. You are now ready to make alternating welds, beginning with Schedule 1, by just
pressing on the Foot Switch to activate each weld.