Basic
information
Classic Q1
5
Te
chn
ical
data
2.3
Technical data
Q1 230/180-x
Power connection:
200 … 250 V~
Auxiliary voltage connection:
200 … 250 V~
Output voltage:
± 180 V
=
Cooling:
self cooling
Q1 230/180
15
25
40
Input current
A~
16.5
27.5
44
Output current
- peak 5s
- continuous
A
=
A
=
30
15
50
25
80
40
Electric power
kW
2.7
4.5
7.2
Dimensions
mm
200x240x100 200x240x100
200x240x127
Weight
kg
Fuses
(fast acting)
Input
Output
A
A
20
35
30
50
50
63
Mains choke
Type
K78-16
K84-25
K84-50
mH
1.2
0.7
0.5
Motor choke
Type
El 135A-16
EI 135B-24
EI 150B-40
mH
33
16
7
Q1 400/300-x
Power connection:
360 … 440 V~
Auxiliary voltage connection:
360 … 440 V~
Output voltage:
max. ± 300 V
=
Cooling:
self cooling
Q1 400/300
15
25
40
Input current
A~
16.5
27.5
44
Output current
- peak 5s
- continuous
A
=
A
=
30
15
50
25
80
40
Electric power
kW
4.5
7.5
12.0
Dimensions
mm
200x240x100 200x240x100
200x240x127
Weight
kg
Fuses
(fast acting)
Input
Output
A
A
20
35
30
50
50
63
Mains choke
Type
K78-16
K84-25
K84-50
mH
1.2
0.7
0.5
Motor choke
Type
EI 135B-16
EI 150C-24
UI 120B-40
mH
45
30
15
(Inductivity for larger armature circuits on request)