Settings
Classic Q1
19
Co
m
m
is
sio
n
in
g Q
1
x
/x
-x
w
ith REGx
x
5.3
Commissioning Q1 x/x-x with REGxx
Check the connections prior to any commissioning.
Observe the type plate!
Basic power connections Q1
Mains connection
Power
Terminal
X10:15, X10:16
Mains connection
Auxiliary voltage
Terminal
X5:14, X5:17
Field
Terminal
X5:18
Mains connection
A1/A2
Terminal
X10:10, X10:12
Motor connection
F1/F2
Terminal
X5:19, X5:20
Field connection
PE
Earth screws PE on the housing
Basic control connections REGxx
Enable
Contact between X1:3 and X1:4
Command value
Signal X1:6
GND X1:8a
Actual value
Signal X1:9
GND X1:8b
Shields
X1:8
Control electronics REGxx
Switch
S4
P-ampl.
Position 4
Switch
S5
I-comp.
Position 4
Switch
S8
D-ampl.
Position 8
Switch
S9
Actual value
Position 8
Potentiometer
I
1
Peak current
10%
Potentiometer
I
2
Peak current
10%
Potentiometer
ID
Continuous current
100%
Potentiometer
X
P
Amplification
50%
Potentiometer
INT
Integrator
Left full scale
Potentiometer
n
max
Speed
Left full scale
Potentiometer
Offset
Offset
50%