![Unitek BAMOCAR D3 Manual Download Page 16](http://html1.mh-extra.com/html/unitek/bamocar-d3/bamocar-d3_manual_4027993016.webp)
15
BAMOCAR D3
Basic information
Te
chni
cal
d
at
a
2.14
Technical data
For three-phase current motors
Auxiliary voltage connection
12V= to 700V=
Auxiliary voltage connection
12V= or 24V= ±10% / 4A (2A)
residual ripple <10%, regenerating fuse
Data BAMOCAR D3-400-(700)
Dim.
125/250
200/400
125/250
200/400
Supply voltage, rated value
V=
24 up to max. 400
24 up to max. 700
Max. output voltage, rated value
V~eff
up to 3x260
up to 3x450
Continuous current
A
eff
125
200
125
200
Max. peak current
A
lo
250
400
250
400
Max. power loss
kW
2
3
2.6
4
Pulse frequency
kHz
8-24
8-16
Over-voltage
switching threshold
V=
440
800
Input fuse
A
160
250
160
250
Weight
kg
8.5
Dimensions h x w x d
mm
403x250x145
Size
2
Control signals
V
A
Function
Connector
Analogue inputs
± 10
0.005
Differential input
X1
Digital inputs
ON
OFF
10-30
<6
0.010
0
Logic IO
X1
Digital outputs
+24
1
Transitor output
open emitter
X1
Resolver / TTL / SINCOS
Differential input
X7
CAN interface
Logic IO
X9
RS232 interface
Logic IO
X10