![Unitek BAMO A1 Manual Download Page 12](http://html1.mh-extra.com/html/unitek/bamo-a1/bamo-a1_manual_4028908012.webp)
12
BAMO A1, A2 60-500A
Control Connection
The connecting advices are for general information and without obligation
Notice:
- Connecting- and operating instructions
- Local regulations
- EU-machine regulation
pin-No. terminal block
X1: 1 up to X1:7 and X2 : 8 up to X2 : 14
Signal lines
- Shielded and seperated from power lines.
- command values paired twisted and shielded.
Logical connections
- Relay with gold contacts or reed relays. Contact current 6mA.
Enable -internal logical voltage
- internal logical voltage
X1:1
+15V/10mA
- contact chain between
X1:1 and
X1:2
Enable -external logical voltage
- enable v10 … +30V
X1:2
- GND
X1:7
Switch on enable
- command value and speed controller are enabled immediately.
Switch off enable
- command value and speed controller are enabled stop
- command value
>>>
is switched internally immediately to 0
- after 2 seconds
>>>
speed controller is locked.
Caution:
Make sure that the battery voltage is connected to the device at least for 10 seconds
after switching off the enable.
Auxiliary voltage connection
- Direct voltage command 24V=
- Operating range 19V up to 54V=
- Rated current 0.5A, inrush current 2A
- Residual ripple <20%
- Fusing 2AF
Caution:
when using a switching power supply for auxilary voltage.
Switch on power supply before connecting auxiliary voltage (K2).
C
o
n
n
e
cti
o
n