3 Electrical installation
Power Connection
Caution:
The connection advices concerning the individual attachment of the connections to
the plug numbers or terminals are binding.
All further advices to this are not binding.
The input and output lines can be altered or completed in consideration of the
electrical regulations.
Notice:
- connection and operation advices
- local technical regulations
- EU-machine regulation 89/392/EWG,
84/528/EWG, 86/663/EWG
- CE-advice, EMC
Connection lines
Caution :
with longer lines >>> use a one step strengther cross section !
Auxiliary voltage 24V=
Battery voltage
DC - motor
D1
brake current-
diode for A2
C
o
n
n
e
ct
io
n
a
d
vi
ce
Caution:
Risk off distruction by
overvoltage in buffer circuit
Using BAMO-A2-36 the batterie
voltage (U
B
+ X3:10 , U
B
- X3:2)
must be applicated to the device
10s before switching on and 10s after
switching off enable to limitate a
possible occuring brake voltage by
the battery everse current protection
diode D1 against uncontrolled
disconnecting the battery voltage
while braking.
If using a DC-Bus notice advices on
page 10.
Dimensioning
at A
60
120
240
280
Battery lines (max. 2m) mm
2
10
35
95
120
Motor lines
mm
2
10
35
95
120
Fuse F1
A
89
160
360
500
Auxiliary voltage line
mm
2
0.5
Fuse F2
A
2A