DOC. NO.
:
Page11
And the reply signals are defined as:
Receive a valid
command
Name
Length
Value1 Value2 Value3 Value4
CR
Byte Count
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte 1 Byte
Bytes order
1
2
3
4
5
6
Receive a non-
valid
command
Name
ACK
CR
Byte Count
1 Byte
1 Byte
Bytes order
1
2
Data
‘-‘
(0x2D)
CR
(0x0D)
Example of get functions:
Get
Power status
Command (ASCII):
Name
Length
Command
Value1
Value2
Value3
CR
Byte Count
‘5’
(0x35)
‘l’
(0x6C)
‘0’
(0x30)
‘0’
(0x30)
‘0’
(0x30)
CR
(0x0D)
Bytes order
1
2
3
4
5
6
If the monitor is turn on, it will reply
Name
Length
Value1
Value2
Value3
Value4
CR
Byte Count
‘5’
(0x35)
‘0’
(0x30)
‘0’
(0x30)
‘0’
(0x30)
‘1’
(0x31)
CR
(0x0D)
Bytes order
1
2
3
4
5
6
If it is turn off, then it will reply
Name
Length
Value1
Value2
Value3
Value4
CR
Byte Count
‘5’
(0x35)
‘0’
(0x30)
‘0’
(0x30)
‘0’
(0x30)
‘0’
(0x31)
CR
(0x0D)
Bytes order
1
2
3
4
5
6
Summary of Contents for UniSign-4813A
Page 6: ...DOC NO Page6 1 5 Absolute Maximum Ranges...
Page 16: ...DOC NO Page16 4 Mechanical Specifications...
Page 17: ...DOC NO Page17...
Page 29: ...DOC NO Page29 7 3 Carton Label Definition 65 65mm 7 4 Carton Label Position...
Page 30: ...DOC NO Page30 8 Packing 8 1 Carton Packing...