background image

P/N 466-5249 

• REV B • 13OCT16                                                           © 2016 United Technologies Corporation. All rights reserved.

   

 
 
 
 
 

 

Installation Sheet  

Enrolling

 

To enroll the sensor, set your panel into program mode. Then go to the Learn Sensors menu. Refer to your 
specific alarm panel manual for details on these menus. With the battery installed, activate the case tamper by 
sliding the cover up and down. You will hear a click when the case latches are engaging and disengaging. 
Continue until the panel responds to the sensor. Then select the appropriate sensor group and number. 

Mounting 

One side of the sensor is marked with 3 lines; this indicates the location of the reed switch. The magnet should 
be mounted facing this 

side of the sensor, and it must be no further than 5/8” (15.875mm) from the sensor. 

 
Included with this device is double sided tape for the contact and the magnet. Choose a suitable location for the 
sensor by following the procedure in the section “Testing the Sensor” ensuring desired signal strength is 
achieved

.

 For reliable bonding, ensure the surface is clean and dry. Apply the tape to the sensor and then to the 

desired location. Apply firm pressure for several seconds.  
 

Note:

 When mounting with double sided tape, ensure temperatures are above 50°F and will remain above 50°F 

for at least 24 hours to ensure proper bond. After 24 hours, the bond will hold at lower temperatures. 
 
Where possible, install sensors within 100 ft. (30 m) of the panel. While a transmitter may have an open-air 
range of 500 ft. (150 m) or more, the environment at the installation site may have a significant effect on 
operational range. Changing a sensor location may improve wireless communication. 

Interchangeable covers

 

The contact comes from the factory assembled with a white cover, but included are optional brown covers. To 
change the cover, simply slide the front cover to disengage it from the sensor, and then remove. Replace with 
the brown cover ensuring the Top (as marked on the inside of the cover) points away from the battery. You 
should hear a click when the cover engages and disengages from the sensor. You do not need to replace the 
back plastic because once mounted the back is not visible. To replace the magnet cover, you will need to gently 
pry the white cover off with a flat head screw driver and snap the brown cover in place. 
 

Testing the Sensor (Test Weekly)  

The sensor test verifies proper communication between the sensor and the panel/receiver. To test the sensor, 
refer to the specific panel/receiver documentation and do the following: 
1. Put the panel/receiver into sensor test mode. 
2. Open the door/window the sensor is protecting. The sensor transmits a signal. 
3. Listen for siren beeps to determine the appropriate response. 
4. Exit sensor test mode. 
 

Installing / Replacing the Battery 

When the battery is low a signal will be sent to the control panel. To install/replace the battery: 
1.  Slide the top cover to disengage it from the sensor. Then remove to reveal the battery. 
2.  Install/replace with a CR2032 battery ensuring the + side of the battery faces towards you. 
3.  Re-attach the cover. Ensure the Top (as marked on the inside of the cover) points away from the battery. 

You should hear a click when the cover engages properly. 

 

Note

: Removing the cover will trigger a zone tamper signal to the control panel. 

 

 
 
 
 

TX-E201 Door/Window Sensor 319.5MHz

  

 

Reviews: