International Shock Sensor Installation Instructions
Reed switch setting
After adjusting the Shock Sensor’s sensitivity, set DIP switch 5
to the appropriate setting, ON for enabled and OFF for
disabled.
RF testing
This section describes the basic steps for testing the sensor.
Refer to the specific panel or receiver documentation for
complete testing details.
1. Set the panel to Sensor Test.
2. Trip the sensor.
3. Listen for appropriate response from system sirens.
4. Exit Sensor Test.
Battery replacement
When the system indicates that the sensor has a low battery,
remove the old battery and install a new battery (Duracell
DL123A or a Sanyo CR123A) into the battery holder, observing
proper polarity.
Caution:
Replace only with Duracell DL123A battery or a
Sanyo CR123A battery. Observe polarity when installing a new
battery. Installing the battery backwards may cause damage to
the sensor. Dispose of used batteries according to the
manufacturer
’s instructions and/or local government
authorities.
Specifications
Compatibility
All 433 MHz Learn Mode panels and
receivers
Case dimensions
3.5 x 15.2 x 3.2 cm
Operating temperature
0 to +
50°C
Storage temperature
−34 to +60°C
Maximum relative humidity 90%, noncondensing
Battery
Duracell DL123A or Sanyo CR123A 3V
Lithium
Wireless operating
frequency
433.05 MHz - 434.04 MHz
Maximum power output
10 dBm
Transmitter range
150 m open air
Notices
Approved for use in the following countries:
Austria
France
Ireland
Belgium
Germany
Italy
Denmark
Greece
Netherlands
Finland
Iceland
United Kingdom
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
European Union
directives
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
www.utcfssecurityproducts.eu
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection
points. For more information see:
www.utcfssecurityproducts.eu/recycle/
This product may contain a battery that cannot be
disposed of as unsorted municipal waste in the
European Union. See the product documentation
for specific battery information. The battery is
marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling return the
battery to your supplier or to a designated
collection point. For more information see
www.utcfssecurityproducts.eu/recycle/
Contact information
or