background image

 

International Shock Sensor Installation Instructions  

Figure 7: Sensor base mounting holes and magnet alignment 

 

3.  Position the shock element and press it firmly into its 

socket (see Figure 7 above). 

4.  If using the reed switch, use the two remaining screws to 

mount the magnet so that its arrow is aligned with the 

arrow on the sensor case (see Figure 7 above). 

Adjusting the shock sensor 

The following describes the DIP switch functions: 

• 

DIP Switches 1 and 2

—adjust the Pulse Count. 

• 

DIP Switches 3 and 4

—adjust the sensitivity setting of 

Gross Attack detection. 

• 

DIP Switch 5

—enable/disable reed switch. 

• 

DIP Switch 6

—not used. 

Note: 

In order for the LED to indicate shock detection while 

adjusting the sensitivity, be sure the reed switch is disabled 

(DIP switch 5 OFF) or that the magnet is lined up with the reed 

switch if DIP switch 5 is ON. 

Gross attack adjustment 

1.  To adjust the sensor for Gross Attack, set DIP switches 1 

and 2 to the ON position. This disables the Pulse Count so 

that the unit can only be activated by a Gross Attack. 

2.  Apply high level shocks to the mounting structure, using 

the LED as a guide to when the alarm trips (LED on for 4 

seconds). 

3.  The LED will blink for 1 second every time the sensor 

detects a pulse. A shock that is severe enough to cause 

an alarm will cause the LED to light for approximately 4 

seconds. 

4.  Use switches 3 and 4 to adjust the Gross Attack sensitivity 

of the sensor (see Table 1 below). 

5.  Repeat step 2 each time you make a sensitivity change. 

Table 1: Gross attack sensitivity settings 

DIP Switch 3 

DIP Switch 4 

Sensitivity 

OFF 

OFF 

1 (maximum sensitivity) 

ON 

OFF 

OFF 

ON 

ON 

ON 

4 (minimum sensitivity) 

Pulse count adjustment 

1.  Set the sensor to the desired Pulse Count (see Table 2 

below). 

2.  To test the pulse count setting, generate small shocks on 

the mounting structure. Each time a shock is detected, a 

pulse is registered in memory and the LED will blink for 

one second. If the programmed pulse count is reached 

within the most recent 30 seconds, the alarm will trip and 

the LED will light for approximately 4 seconds. If the alarm 

trips for any reason, the stored pulses are cancelled. 

3.  Use switches 1 and 2 to adjust the Pulse Count. 

Note:  

Pulse Count signals are counted at 1-second intervals 

and stored in a 30-second digital memory. These small signals 

can detect an intruder gently prying open a window or door 

frame. 

Table 2: Pulse count adjustment 

DIP Switch 1 

DIP Switch 2 

Pulse count 

OFF 

OFF 

ON 

OFF 

OFF 

ON 

ON 

ON 

Disabled 

System programming 

This section describes the basic steps for adding the sensor to 

panel memory. Refer to the specific panel documentation for 

complete programming details. 

1.  Enable the reed switch by setting DIP switch 5 to ON. The 

reed switch must also be open (no magnet near). 

2.  With the cover off the sensor, set the panel to program 

mode. 

3.  Proceed to the Learn Sensors menu. 

4.  Select the appropriate sensor group and sensor number 

assignments. 

5.  When prompted by the panel to trip the sensor, press and 

release the cover tamper switch. 

6.  Exit program mode. 