21
12.2
95-8616
APPENDIX C
ATEX APPROVAL DESCRIPTION
The following items, functions, and options describe the ATEX approval.
APPROVAL
Electrochemical Gas Detector, GT3000 Series.
Explosion Proof Model
0539
FM
APPROVED
®
II 2(1)G.
Ex d mb [ia Ga] IIC T4 Gb IP66.
FM10ATEX0009X.
NOTE
The GTX Gas Transmitter module shall be connected directly to a junction box suitable for the area of
installation to provide protection for the flying leads.
Intrinsically Safe Model
0539
FM
APPROVED
®
II 1 G Ex ia IIC T4 Ga IP66.
FM08ATEX0045X.
NOTE
In order to maintain the intrinsically safe rating of the transmitter, the device must be powered through an
approved I.S. barrier.
For a list of recommended barrier models, refer to Tables 3 and 4. For additional information regarding
proper I.S. installation, refer to the Control Drawings in Appendix H of this manual.