background image

* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.

© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380      Ph. 800-750-2723

THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified to comply with 2020 particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For 
your  safety,  follow  the  installation  instructions.  Never  use  make-shift  compromises 
during  the  installation  of  this  heater.  Contact  local  building  or  fire  officials  about 

permits, restrictions and installation requirements in your area. NEVER OPERATE THIS 
PRODUCT WHILE UNATTENDED.

CAUTION!  Please  read  this  entire  manual  before  you  install  or  use  your  new  room 

heater. Failure to follow instructions may result in property damage, bodily injury, or 

even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals 

including carbon monoxide, which is known to the 

State of California to cause cancer, birth defects, 

and/or other reproductive harm. For more 

information, go to 

www.P65warnings.ca.gov

852050L-0204K

VG5770

Certified to ASTM E1509-12 (2017) 

and ULC-S627-00-REV1

Mobile Home Approved

R

Report #: F20-578

Model Number:

Summary of Contents for VOGELZANG VG5770

Page 1: ...ding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or us...

Page 2: ...stallation and operation of the Vogelzang VG5770 wood heater This heater meets the 2020 US Environmental Protection Agency s wood pellet emissions limits for wood heaters sold after May 15 2020 Under...

Page 3: ...________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Instal...

Page 4: ...NG SMOKE DETECTOR MUST BE INSTALLED IN THE SAME ROOM AS THIS PRODUCT INSTALL A SMOKE DETECTOR ON EACH FLOOR OF YOUR HOME INCASE OF ACCIDENTAL FIRE FROM ANY CAUSE IT CAN PROVIDE TIME FOR ESCAPE THE SMO...

Page 5: ...ions Any reduction in clearance to combustibles may only be done by means approved by a regulatory authority E F G E F G H H H H TABLE 1 CLEARANCES in mm PARALLEL E Back wall to unit 3 76 F Sidewall t...

Page 6: ...E OR STOVE DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT The following installation guidelines must be followed to ensure conformity with both the safety listing of this stov...

Page 7: ...aled with silicone or other means to maintain the vapor barrier between the exterior and the interior of the home Vent surfaces can get hot enough to cause burns if touched by children Noncombustible...

Page 8: ...bove the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this...

Page 9: ...rolled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat...

Page 10: ...n diameter and not over 1 long Longer or thicker pellets sometimes bridge the auger flights which prevents proper pellet feed Burning wood in forms other than pellets is not permitted It will violate...

Page 11: ...ass door and prevent the rapid buildup of creosote inside your stove and chimney You should adjust the damper based on the fire s appearance A low reddish dirty fire can be improved by turning the dam...

Page 12: ...before restarting your stove On other units the thermodisc has no reset button and will reset itself once the stove has cooled The manufacturer recommends that you call your dealer if this occurs as...

Page 13: ...fessionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combusti...

Page 14: ...s HOT Do not attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Once the heater has cooled...

Page 15: ...ail parts usstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered B...

Page 16: ...lower heat setting Fuel other than wood pellets is being burned in the stove This pellet stove is designed and tested to use wood pellets Check for signs of fuel other than wood pellets No other type...

Page 17: ...turn the shaft is jammed on something If the motor will not turn the motor is bad The Proof of Fire POF thermodisc has malfunctioned Temporarily bypass the POF thermodisc by disconnecting the two wir...

Page 18: ...can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in...

Page 19: ...joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with the same RTV The gasket on the combustion blower has gone bad I...

Page 20: ...connector Bad control board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is not a full current go...

Page 21: ...2021 United States Stove Company 21 CORRECT WRONG ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN WIRING DIAGRAM...

Page 22: ...22 2021 United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 REPAIR PARTS...

Page 23: ...on 1 32 83537 Hose Clamp 1 33 88176 Insulating Blanket 1 34 88177 Gasket Ash Clean out 2 35 88175 Gasket T disc 2 36 80601 T Disc Room Air 1 37 88167 Gasket Room Blower 1 38 80604 Igniter 1 39 80622 R...

Page 24: ..._ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No __________________________...

Page 25: ...______________ Service de 07 Date _______________________ Nom de l ing nieur __________________________________ N de licence _______________________________________ Compagnie _________________________...

Page 26: ...Couverture isolante 1 34 88177 Joint Ash Clean out 2 35 88175 Joint T disque 2 36 80601 T Disc Chambre Air 1 37 88167 Joint Chambre Blower 1 38 80604 Igniter 1 39 80622 Chambre Blower 1 40 80549 Inter...

Page 27: ...22 2021 United States Stove Company 1 2 3 4 8 9 15 17 19 34 20 21 22 23 27 28 29 30 35 36 37 38 40 41 24 25 5 6 7 43 18 26 33 14 1 16 18 39 42 12 13 31 32 SCH MA DES PI CES...

Page 28: ...2021 United States Stove Company 21 CORRECT FAUX ASSUREZ VOUS QUE LES FILS SONT CONNECT S AUX DEUX BROCHES INF RIEURES DE L INTERRUPTEUR DE LA TR MIE COMME ILLUSTR SCH MA DE C BLAGE...

Page 29: ...t bien fix e la tige du registre d admission Lorsqu on d place la tige du registre la plaque doit se d placer avec elle Blocage du conduit d admission d air Inspecter visuellement le conduit d admissi...

Page 30: ...re l origine du blocage Fil d branch ou connecteur desserr V rifiez tous les fils et connecteurs branch s sur le moteur de tari re l interrupteur de surchauffe et le connecteur Molex Tableau de comman...

Page 31: ...tions possibles D branchez le po le avant toute chose quand c est possible Il y a une fuite dans le syst me de conduit d vacuation Inspectez tous les raccords de tuyaux d vacuation Assurez vous qu ils...

Page 32: ...re L arbre de la tari re est coinc Commencez par vider la tr mie Puis retirez le moteur de la tari re en retirant la goupille de la tari re Retirez la plaque d inspection de l arbre de la tari re dans...

Page 33: ...ue chose Si le moteur ne tourne pas il est d fectueux Le thermodisque de d tection de feu POF a mal fonctionn Contournez temporairement le thermodisque POF en d branchant les deux fils et en les racco...

Page 34: ...hauffe potentielle Dans ce cas essayez d utiliser un r glage de chauffage inf rieur Un autre combustible que les granul s de bois est br l dans le po le Ce po le granul s a t con u et test pour br ler...

Page 35: ...orrectement tout le verre cass Seul le verre c ramique haute temp rature de la taille et de l paisseur appropri es peut tre utilis NE PAS substituer les mat riaux alternatifs pour le verre Contactez v...

Page 36: ...ner le flux normal d vacuation Elles doivent donc tre p riodiquement limin es ENL VEMENT ET LIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE PO LE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIEN OU NETTOYAG...

Page 37: ...a refroidi Le fabricant vous recommande de vous adresser au revendeur si cela se produit car cela peut indiquer un probl me plus grave Il peut s av rer n cessaire d appeler le service de r paration 2...

Page 38: ...diff rentes marques de granul s et des d bits d alimentation des granul s Il vous permet d am liorer l efficacit de votre po le Fournir un air de combustion correct r duira la fr quence de nettoyage...

Page 39: ...er les ailettes de la tari re ce qui emp che une bonne alimentation en granul s Il est interdit de br ler du bois sous d autres formes que des granul s Il s agirait d une violation des codes du b time...

Page 40: ...ement du po le peut tre Manuel ou command par un Thermostat Des diodes distinctes gauche de l cran deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le po le doit tre en mode de fonct...

Page 41: ...a neige est abondante il est recommand que la sortie de l installation se trouve plus de 3 pi 0 91 m pour chapper la ligne de cong re Cette m me installation peut tre utilis e si le po le se trouve so...

Page 42: ...0 50 Tous les raccords du syst me d vacuation doivent tre fix s par au moins 3 vis et scell s avec une colle de silicone RTV haute temp rature pour les rendre tanches l air La zone o le conduit d vacu...

Page 43: ...CIFI S PAR LE FABRICANT D VACUATIONS NE RELIEZ PAS L VACUATION POUR PO LE GRANUL S UNE VACUATION UTILIS E POUR UN AUTRE APPAREIL OU UN AUTRE PO LE N INSTALLEZ PAS DE REGISTRE DE TIRAGE SUR LE SYST ME...

Page 44: ...combustibles ne peut tre effectu e que par des moyens approuv s par une autorit r glementaire E F G E F G H H H H TABLE 1 CLEARANCES po mm Parall le E Mur arri re l appareil 3 76 F Mur lat ral au con...

Page 45: ...N IMPORTE QUELLE CAUSE CE DISPOSITIF PEUT LAISSER LE TEMPS DE S CHAPPER LE D TECTEUR DE FUM E DOIT TRE INSTALL AU MOINS 15 PIEDS 4 57 M DE L APPAREIL AFIN D VITER QU IL NE SE D CLENCHE INUTILEMENT LOR...

Page 46: ...date d inspection du syst me de ventilation existant _______________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment au...

Page 47: ...le fonctionnement des appareils de chauffage au bois Vogelzang VG5770 Ce po le respecte les limites d mission de pellets de bois impos es par la US Environmental Protection Agency en 2020 pour les po...

Page 48: ...les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser...

Reviews: