background image

-2-

CAUTIONS:

• 

Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.

• 

Do not use chemicals or fluids to ignite the fire.

• 

Do not leave the stove unattended when the door is slightly opened.

• 

Do not burn garbage, flammable fluid such as gasoline, naphtha or motor oil.

• 

Do not connect to any air distribution duct or system.

• 

Always close the door after the ignition.

Combustible:

Wood

Colors:

Metallic Black

Flue Pipe Diameter:

6” (153 mm)

Flue Pipe Type: (Standard Single Wall or Double 

Wall):

Black or Blued Steel 2100°F (650°C)

Minimum Chimney Height:

12’ (3.7 m)

Maximum Log Length:

21” (534 mm)

Dimensions
Overall: Depth x Width x Height:

21.5” x 32” x 33.5” (547 mm x 813 mm x 864 mm)

Combustion Chamber: Width x Depth:

11-3/8” x 24-3/4” (289 mm x 629 mm)

Volume: Cubic Feet:

2.32 ft³

Door Opening: Width x Height:

10” x 11-3/8” (854 mm x 289 mm)

Note: Register your product on line at www.usstove.com. Save your receipt with your records for any claims.

The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627-00 

(R2016) standards. This manual describes the installation and operation of the Vogelzang, VG4020 wood heater. 

This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters 

sold after May 15, 2020. Under specific test conditions, this heater has been shown to deliver heat at rates ranging 

from 17,611 to 48,127 Btu/hr (0.91g/hr and efficiency of 72%). Note: The BTU ratings mentioned above are based on 

the EPA test protocol under specific test conditions. Our advertised BTU’s are based on the first hour of operation 

at high burn rate burning cordwood.

Summary of Contents for VOGELZANG VG4020

Page 1: ...015 and Certified to ULC S627 00 REV1 Room Heater Solid Fuel Type Also For Use In Mobile Homes USA Only SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM TH...

Page 2: ...epth 11 3 8 x 24 3 4 289 mm x 629 mm Volume Cubic Feet 2 32 ft Door Opening Width x Height 10 x 11 3 8 854 mm x 289 mm Note Register your product on line at www usstove com Save your receipt with your...

Page 3: ...knob assembly 1 Remove the machine screw and the door knob 2 Place the knob on the outside of the cabinet door re install the machine screw and tighten Be careful not to strip out the threads in the...

Page 4: ...ire department Do not connect to any air distribution duct or system A source of fresh air into the room or space heated shall be provided when required POSITIONING THE STOVE It is very important to p...

Page 5: ...etween the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floo...

Page 6: ...st of possible indicators that a source of outside combustion air may be required The stove does not draw steadily smoke rollout occurs wood burns poorly or back drafts occur whether or not there is c...

Page 7: ...controllable burn or excessive temperature indicates excessive draft 3 screws Flow Direction of Flue Gases Install crimped end towards stove Male Part Downwards 1 4 slope per foot CHIMNEY Take into ac...

Page 8: ...Clearance to Combustibles Combustible Wall Floor Protector To Stove Storm Collar Flashing Listed Chimney Attic Insulation Sheild Specified Clearance Chimney Connector Combustible Ceiling Joists To Sto...

Page 9: ...ey connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fib...

Page 10: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Page 11: ...s 6 Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains 10 Salt water driftwood or other previously salt water saturat...

Page 12: ...uired to properly burn coal or coal products Do not elevate the fire using grates or irons Build the fire directly on the firebrick FUELING INSTRUCTIONS This wood stove has been certified by the US EP...

Page 13: ...tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration of these tubes may reduce the efficiency of combustio...

Page 14: ...between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP Al...

Page 15: ...posure It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO GASKET CARE This unit s door uses a 1 diameter rope gasket It is recommended that you chan...

Page 16: ...e Collar Gasket 1 6 891492 Blower Assembly B36 1 7 25598 Blower Mounting Box 1 8 29329 Smoke Curtain 1 9 610508 Right Side Casing 1 10 67969 Cabinet Door Assy 1 11 67444 Ash Pan Weldment 1 12 67859 Ba...

Page 17: ...2 5 ft 8 40764 Cast Door 1 3 5 8 1 2 7 6 4 2 1 3 5 4 6 7 8 9 10 11 14 13 15 16 18 17 12 Key Part Description Qty 1 88336 Insulation Blanket 1 2 88335 Baffle Board 2 3 29437 Tube Retainer 1 4 29438 Ba...

Page 18: ...ame _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ______________________________________ S...

Page 19: ...ice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pi ces de rechange Conservez ce manuel dans un endroit s r pour r f rence future Lors de l criture...

Page 20: ...12 67859 Soudure De Base 1 13 22110 Bouclier Thermique 1 14 25550 Amortisseur De Tirage H pin 1 15 27469 Bras Amortisseur 1 16 610987 Ensemble De Bo te De Distribution D air 1 17 89687 Bouton De Ther...

Page 21: ...16 Pi ces De Rechange 1 2 3 4 6 7 9 10 11 12 13 14 15 16 17 19 20 21 22 23 18 24 25 26 27 5 8...

Page 22: ...METTEZ PAS AU CORDON D ALIMENTATION DE TOUCHER LES SURFACES CHAUDES GARDER LE CORDON D ALIMENTATION AU MOINS 12 po 30 5CM DES SURFACES DU PO LE OU DU TUYAU DANGER RISQUE D LECTROCUTION D BRANCHER LA S...

Page 23: ...FAIRE FONCTIONNER LE PO LE LE CENDRIER PEUT DEVENIR TR S CHAUD PORTER DES GANTS POUR PR VENIR LES BLESSURES NE BR LEZ JAMAIS LE PO LE AVEC LE PI GE CENDRES OUVERT CELA POURRAIT PROVOQUER PLUS DE CUISS...

Page 24: ...atement le registre pour r duire l alimentation en air et ralentir le feu Entretien De La Chemin e AVERTISSEMENT Les feux combustion lente pour une utilisation prolong e ou la combustion de bois vert...

Page 25: ...br l jusqu un lit de charbon de d marrage chargez l unit avec environ 24 lb de carburant pour la premi re charge de combustion lev e Fermez la porte imm diatement Apr s la premi re charge de combusti...

Page 26: ...Ce chauffage au bois a un taux de combustion minimum r gl la fabrication et qui ne peut tre modifi La modification de ce r glage ou une utilisation autre de ce chauffage au bois qui ne respecterait pa...

Page 27: ...is utilis tait trop humide ou avait s ch dans de mauvaises conditions Ces probl mes peuvent tre probl mes d allumage accumulation de cr osote causant des incendies de chemin e rendement nerg tique bas...

Page 28: ...o minimum aux mat riaux combu ibles Chemin e en ma onnerie Conduit de chemin e Doublage en argile r fractaire Conduit de raccordement D gagement minimum de 30 cm 12 po 304 8 mm des briques Le d gageme...

Page 29: ...ment appropri avec la structure tel que recommand par le fabriquant La chemin e doit avoir la hauteur requise au dessus du toit ou d autres obstructions pour des raisons de s curit et un bon tirage Re...

Page 30: ...e fabriqu e en usine elle doit r pondre la norme UL 103 et CAN CSA B365 par cons quent elle doit tre de type HT 2100 F Il est extr mement important qu elle soit install e conform ment aux sp cificatio...

Page 31: ...d indicateurs possibles indiquant qu une source d air de combustion ext rieur peut tre requise Votre po le n effectue pas un tirage uniforme produit des retours de fum e ne br le pas bien le combusti...

Page 32: ...e l avant de l appareil Le jeu entre le conduit de fum e et un mur est valable uniquement pour les parois verticales et conduit de fum e vertical Le connecteur de chemin e ne doit pas passer travers u...

Page 33: ...ION CONSULTER VOTRE SERVICE MUNICIPAL IMMEUBLE OU D INCENDIE PROPOS DE PERMIS RESTRICTIONS ET INSTALLATIONS EXIGENCES DANS VOTRE R GION UTILISATION D TECTEUR DE FUM E DANS LA PI CE O EST INSTALL VOTRE...

Page 34: ...a poign e de porte 2 Placez le bouton l ext rieur de la porte de l armoire r installez la vis m taux et serrez Veillez ne pas retirer les fils de la poign e FONCTIONNEMENT DE LA POIGN E ET DE LA PORTE...

Page 35: ...construction de 2020 de la US Environmental Protection Agency pour les appareils de chauffage au bois vendus apr s le 15 mai 2020 Dans des conditions de test sp cifiques il a t d montr que cet appare...

Page 36: ...Z DANS UN ENDROIT S R POUR R F RENCE FUTURE U S Environmental Protection Agency Certifi pour se conformer aux normes d missions de particules de 2020 AVERTISSEMENT CONCERNANT LA PROPOSITION 65 DE L TA...

Reviews: