background image

853580B-4203i

MODEL: VG2520

Certified to: UL 1482-2011 (R2015) and 

ULC-S627-00 (R2016)

Mobile home approved (U.S. ONLY)

U.S. Environmental Protection Agency 

Certified to comply with 2020 

particulate emissions standards.

R

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

Report Number: F19-487

United States Stove Company

PO Box 151, 227 Industrial Park Rd.,

South Pittsburg, TN 37380

PH: (800) 750-2723

www.usstove.com

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result. 

For  your  safety,  follow  the  installation  instructions.  Never 

use make-shift compromises during the installation of this 

heater. Contact local building or fire officials about permits, 

restrictions and installation requirements in your area.

CAUTION!

Please read this entire manual before you install or use your 

new room heater. Failure to follow instructions may result in 

property damage, bodily injury, or even death. Improper 

Installation Could Void Your Warranty!

Save  these  instructions.  This  manual  will  help  you  to  obtain 

efficient, dependable service from the heater, and enable 

you to order repair parts correctly. Keep in a safe place for 

future reference.

Summary of Contents for VOGELZANG VG2520

Page 1: ...veuillez consulter le site www P65warnings ca gov Report Number F19 487 United States Stove Company PO Box 151 227 Industrial Park Rd South Pittsburg TN 37380 PH 800 750 2723 www usstove com SAFETY NO...

Page 2: ...ack or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7m Maximum Log Length 21 534mm Dimensions Overall Depth x Width x Height VG2520 BL 25 x 27 x 31 25 635 mm x 686 mm x 794 mm VG2520 BP 25 47...

Page 3: ...shown using the 3 5 16 18 x 1 1 2 bolts 3 washers and 3 weld tabs provided in the parts box FIREBRICK CONFIGURATION Replace the Firebrick as shown in the illustration Assembly Instructions TOOLS AND M...

Page 4: ...E IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTME...

Page 5: ...3 13 331 331 D 30 29 762 737 E 10 10 254 254 F 20 20 508 508 OUTSIDE COMBUSTION AIR Your wood stove is approved to be installed with an outside air intake 4FAK which is necessary for a mobile home Thi...

Page 6: ...MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOO...

Page 7: ...o the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built o...

Page 8: ...as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meet...

Page 9: ...connector Use this as a pass through for a minimum 24 gauge single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet me...

Page 10: ...rain or snow also accelerates the drying time A good indicator of if the wood is ready to burn is to check the piece ends If cracks are radiating in all directions from the center then the wood shoul...

Page 11: ...ling on it and close the door If the piece ignites within 90 seconds from the time it was placed into the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood his...

Page 12: ...oom temperature when leaving the system and therefore calculations using this heating value consider the heat going up the chimney as lost energy Therefore efficiency calculated using the lower heatin...

Page 13: ...these gases is somewhere between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREV...

Page 14: ...e sold The glass should be washed only when cold PAINT Only clean your stove with a dry soft cloth that will not harm the paint finish If the paint becomes scratched or damaged it is possible to give...

Page 15: ...6 Flue Collar 1 2 88042 1 4 Rope Gasket 1 3 25845 Air Deflector 1 4 891492 Blower Assembly B36 1 5 26060 Rear Shield 1 6 610926 Rear Ashpan VG2520 BP 1 7 29243 Pedestal VG2520 BP 1 8 29065 Pedestal Fr...

Page 16: ...ndary Air Tube 7 32 2 6 29248 Left Brick Panel 1 7 24103A Half Firebrick Pumice 4 1 2 X 4 1 2 1 8 40561 Ash Plug 1 9 891530A Firebrick 4 5 X 7 5 X 1 25 1 10 89066A Firebrick Pumice 4 1 2 X 9 18 11 891...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Page 20: ...ECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT S R DES FINS DE R F RENCE LORSQUE VOUS NOUS CRIVEZ VEUILLEZ INDIQUER LE NUM RO COMPLET DU MOD LE QUI FIGURE SUR LA PLAQUE SIGNAL TIQUE DE L APPAREIL...

Page 21: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 22: ...cription Qt 1 893156 Poign e en bois 1 2 893164 Poign e de porte 1 3 893062 Manchon rouleau 1 4 83788 Vis t te creuse 1 5 891373 Patin de charni re de porte filet 2 6 40880 grande porte en fonte carr...

Page 23: ...destal VG2520 BP 1 10 610968 Logement en cendrier VG2520 BL 1 11 610883 Soudure de jambe VG2520 BL 4 12 25826 Plaque de foyer 1 13 29216 Cendrier 1 14 610068 Soudure de glissi re d amortisseur 1 15 61...

Page 24: ...retiennent les moulures de la vitre l int rieur de la porte Retirez les moulures et remplacez la pi ce endommag e par une neuve Effectuez la proc dure en sens inverse apr s remplacement Lors du rempla...

Page 25: ...ontinuez en ouvrant la porte tr s lentement ouvrez d un ou deux pouces pendant 5 10 secondes avant de l ouvrir compl tement pour augmenter le tirage et liminer ainsi les fum es qui sont stagnantes dan...

Page 26: ...premi res heures de fonctionnement N ouvrez jamais la commande d air plus que n cessaire afin d obtenir une vitesse de combustion moyenne Assurez vous que la circulation d air soit suffisante lors du...

Page 27: ...b ches br l es la fois pour vous assurer que la temp rature ne d passe jamais 246 C 475 F sur un thermom tre magn tique pour une installation sur des tuyaux de po le paroi simple ou 482 C 900 F sur s...

Page 28: ...z avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 304 mm de diam tre int rieur avec une isolation de 1 25 4 mm ou plus et un raccord de chemin e de 8 de diam tre int rieur...

Page 29: ...n bon tirage CHEMIN E EN MA ONNERIE Assurez vous qu une chemin e en ma onnerie r ponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter...

Page 30: ...p rature excessive indique un tirage excessif Pente de po par pied Partie m le vers le bas 3 vis Vers l appareil Installer l extr mit sertie vers le po le Direction de la circulation des gaz de condui...

Page 31: ...LE PO LE DOIT TRE FIX LA STRUCTURE DE LA MAISON MOBILE UTILISEZ LES DEUX 2 TROUS AU FOND DU PI DESTAL DE LA RADIATEUR POUR FIXER L APPAREIL AU SOL Illustration Fixation Du R chauffeur Au Plancher Util...

Page 32: ...des mati res combustibles 2 Les appareils foyer existants au sein du domicile tels que des chemin es ou d autres appareils de chauffage mettent des odeurs ne fonctionnent pas correctement mettent des...

Page 33: ...l avant de l unit Le d gagement entre le tuyau de carneau et un mur est valable uniquement pour les murs verticaux et pour un tuyau de carneau vertical S il y a un conduit de chemin e horizontal il do...

Page 34: ...LIQUIDE D ALLUMAGE DE CHARBON OU DE LIQUIDES SIMILAIRES POUR D MARRER OU RAVIVER UN FEU DANS CE PO LE MAINTENEZ TOUS CES LIQUIDES LOIGN S DU PO LE EN CAS D INCENDIE DE CHEMIN E FERMEZ COMPL TEMENT LA...

Page 35: ...Visualisation Largeur x Hauteur 16 po x 10 26 po 407 mm x 261 mm ACCESSOIRES EN OPTION DESCRIPTION N PI CE Kit d admission d air ext rieur 4FAK AVERTISSEMENTS CHAUD DURANT LE FONCTIONNEMENT MAINTENEZ...

Page 36: ...issions de particules de 2020 AVERTISSEMENT CONCERNANT LA PROPOSITION 65 DE L TAT DE LA CALIFORNIE Ce produit peut vous exposer des agents chimiques y compris au monoxyde de carbone lesquels sont reco...

Reviews: