-2-
Optional Accessories
Outside Air Intake Kit 4FAK
The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627
standards. This manual describes the installation and operation of the Vogelzang, VG2020 wood heater. This
heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold
after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from
15,261 to 63,196 Btu/hr with 1 g/hr and 70% efficiency. Note: The BTU ratings mentioned above are based on the
EPA test protocol under specific test conditions. Our advertised BTU’s are based on the first hour of operation at
high burn rate burning cordwood.
CAUTIONS:
•
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS.
•
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
•
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
•
DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
•
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
•
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
Combustible:
Wood
Colors:
Metallic Black
Flue Pipe Diameter:
6” (152.5 mm)
Flue Pipe Type:
(Standard Single Wall or Double Wall):
Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height:
12’ (3.7 m)
Maximum Log Length:
21” (533.5 mm)
Dimensions
Overall: Depth x Width x Height:
VG2020-BL
20.46” X 27 X 30.78 (520 mm X 686 mm X 782 mm)
VG2020-BP
20.97” X 27 X 31.25 (533 mm X 686 mm X 794 mm)
Combustion Chamber: Width x Depth: 22-3/4” X 11.78” (578 mm X 300 mm)
Volume: Cubic Feet:
1.6 cubic feet
Door Opening: Width x Height:
18” X 9.75” (458 mm X 248 mm)
Pyroceramic Glass Door:
(Viewing) Width x Height:
16” X 10.26” (407 mm X 261 mm)
Note: Register your product on line at www.usstove.com. Save your receipt with your records for any claims.