background image

USSC

3

Ashes will have to be Removed from the stove periodically.  See cleaning procedure.  You can minimize cleaning required

and maximize efficiency by maintaining the correct draft settings.  See “Draft Setting” further in the manual.

The draft setting on your stove may have to be changed from time to time to accommodate your specific burning conditions.

Proper draft setting will be discussed later in this manual.  The point we wish to make here is that your 

American Harvest

stove, due to the nature of solid fuels, will require brief periodic attention.  Please do not expect to light your stove and walk

away from it until you want to shut if off in the spring.  A few moments of adjustment and cleaning from time to time is an

important part of burning solid fuels, due to the vast differences in fuel, humidity and outside temperature.

The 

American Harvest 

stove has been designed to burn dry shelled corn, wood pellets and other pelletized fuels that meet

Association of Pellet Fuel Industries standards.

SAFETY STEPS

IMPORTANT:

  Proper installation of this stove is necessary for safe and efficient operation.

Installing this product improperly may result in a house fire and personal injury.  All applicable

building codes for your location must be followed.  In areas where building codes require additional

steps to the installation of this product not included in this manual the building codes will take

precedent and must be followed.  Contact your local building inspector to obtain any necessary

permits or inspection guidelines before installing the product.

The 

American Harvest 

stove is designed to burn shelled corn, cherry pits, or pelletized fuel such as

wood pellets.  The burning of other solid fuels such as cord wood or wood chips in this stove is not

permitted.

This product requires simple periodic maintenance for proper  operation and long life of the stove.  Read

and follow the maintenance schedule closely.

DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE!  A power surge protec-

tor is required.

  The unit must be plugged in to a 

grounded

 110-volt power source.

Always route the power cord away from the unit.  Do not route cord in foot traffic areas.  Do not pinch

cord under furniture.

A working smoke detector must be installed in the same room as this product.

Flammable or explosive liquids such as gasoline, naphtha or engine oil must 

NEVER 

be used in or around

this stove.  These liquids must be stored well away from this stove as the open flame in the burner

chamber could ignite the fumes of such liquids.  Do not burn garbage in this unit.

The moving parts of this stove are propelled by high torque electric motors.  The auger and Fuel Agitator

can cause severe injury to body parts that may get near them.  Keep all body parts away from the

auger and Fuel Agitator while the stove is plugged into an electrical outlet.  These moving parts may

begin to move at any time while the stove is plugged in.

According to HUD requirements, when installed in a mobile home, this stove must be grounded directly to

the steel chassis of the mobile home and bolted to the floor.  Direct air access must be provided - Use

60FAK Fresh Air Kit

This stove is not intended for use in commercial installations.

Do not connect this stove to “B” vent.  Use UL Listed Pell Vent ONLY!

BURNING SOLID FUELS

Summary of Contents for American Harvest 6035

Page 1: ...or fire officials about restrictions and installation requirements peculiar to your area Do Not Plug this appliance into an electrical outlet before reading and understanding all operations and alway...

Page 2: ...s you re helping CONSERVE AMERICA S ENERGY CONGRATULATIONS Heat Output 50 000 BTU HR Heating Capacity 1 500 Sq Ft Fuel Storage Capacity 60 Lbs Width 28 in 711mm Height 33 in 838mm Depth 28 in 711mm BT...

Page 3: ...alling the product The American Harvest stove is designed to burn shelled corn cherry pits or pelletized fuel such as wood pellets The burning of other solid fuels such as cord wood or wood chips in t...

Page 4: ...attention to the draft setting on your stove Therefore purchasing corn from the same source will help achieve a more consistent burn DONOTUSECORNWITHAHIGHWAXCONTENT WOOD PELLETS As with corn be consis...

Page 5: ...s to side and back wall combustible materials NOTE These are minimum clearances to combustible walls established by the testing lab The amount of room needed on the left side of the unit to access the...

Page 6: ...nlet elevation It is recommended that at least 5 ft of vertical pipe be installed when the appliance is vented directly through a wall This will create some natural draft to prevent the possibility of...

Page 7: ...When venting into an existing masonry or factory built chimney the chimney must be cleaned with all creosote re moved The chimney must be a type suited for solid fuel WARNING The chimney and the chimn...

Page 8: ...end down or with a wind hood Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simulta neous power failure see diagram above Blockage excessive...

Page 9: ...ON IN A MOBILE HOME WARNING DO NOT INSTALL IN SLEEPING ROOM 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 60FAK 3 Stove must be permanently electricall...

Page 10: ...f the opening a 1 clearance is all that is required ALCOVE CLEARANCE RECOMMENDATIONS ALCOVE THROUGH THE WALL INSTALLATION REQUIREMENTS The stove is approved for horizontal exhaust however we recommend...

Page 11: ...th pipe attached towards wall Pipe B will go through the wall thimble F Be careful not to dislodge the thimble Position stove not closer than 1 to the wall NOTE Make sure that you leave enough clearan...

Page 12: ...Intake Optional 60FAK With 90 Degree Elbow or Hood Pest Guard 3 8 Mesh Maximum Clean Out Cover Tee 3 Min Wall Thimble Flashing Rain Cap or Termination Cap Storm Collar 24 Min INSIDE VERTICAL PIPE WIT...

Page 13: ...Non Combustible Hearth Plate Support Bracket Every 5 Feet 1 Min Keep Attic Insulation Away From Pipe THROUGH THE WALL VERTICAL PIPE INSTALLATION WITH TERMINATION THROUGH THE ROOF The Hearth Pad is no...

Page 14: ...gasket WARNING Do not operate unit with broken glass Do not substitute original factory glass You must use only factory authorized glass Do not slam door shut Do not strike glass Do not use abrasive...

Page 15: ...Manual Draft Adjustment Slide in or out to adjust the amount of draft flowing through the firebox Ash Dump Shutoff Pull out to empty ashes out of the firebox area and back heat exchanger area Make su...

Page 16: ...ve you another 3 minutes before fuel feeds in If the fire is burning too fast and the fuel is being burned up too quickly push the manual draft knob in a little to slow the fire down This should be do...

Page 17: ...used if the home is over 2000 square feet or the weather is extremely cold The high heat setting is intended for use with wood pellets and the highest heat setting for corn would be the number 4 sett...

Page 18: ...changes MAINTENANCE INSTRUCTIONS Surfaces on the front of the stove will be extremely hot during operation Always wear heat resistant gloves to perform periodic maintenance Using a wooden stick tap t...

Page 19: ...will require weekly cleaning Cleaner fuels will allow for monthly cleaning of the exhaust system Remove the exhaust pipe from the back of your stove and remove any ash that may have collected in the...

Page 20: ...AUTOMATIC SAFETY FEATURES Power Outage During a power outage the stove will shut down safely It will not automatically restart when the power returns unless the exhaust is still up to temperature see...

Page 21: ...male terminal connectors one for each wire from wall thermostat Back of Circuit Board It is a good idea to use the thermostat option to achieve uniform control over your heating needs If you are gone...

Page 22: ...hown on page Change to a better grade of fuel if necessary See page 4 regarding fuel quality Check that damper control knob is adjusted properly Pull out to increase fire burn Extend PL Vent to 5 Chec...

Page 23: ...ressure switch or relay Check contents of the hopper Add fuel if necessary Have your USSC reseller diagnose the problem and replace the part s Stove runs for 30 minutes and then shuts down Exhaust gas...

Page 24: ...r fly ash in the house Cleaning the window particularly when the stove is operating Leakage on the joints between the combustion fan exhaust pipe and PL vent This will be evidenced by dust on the impe...

Page 25: ...USSC 25 WIRING DIAGRAM...

Page 26: ...26 USSC REPAIR PARTS DIAGRAM 6035...

Page 27: ...ocket 1 31 80460 Terminal Block 1 N S 80464 Terminal Block Jumper 1 32 80381 Low Limit Switch F110 Thermodisc 60T12 1 33 80381 Distribution Blower Limit Switch F110 Thermodisc 60T12 1 34 80455 Auger S...

Page 28: ...AYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESC...